This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

ABB

2CSF202001R2900

2CSF202001R2900 ABB

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 2CSF202001R2900 ABB

2CSF202001R2900 ABB - F202 AC-100/0.1 Residual Current Circuit Breaker 2P AC type 100 mA

Extended Description for 2CSF202001R2900 ABB

2CSF202001R2900 ABB - F202 AC-100/0.1 Residual Current Circuit Breaker 2P Type AC 100 mA

Free Delivery to UK Mainland on orders over £25

Manufacturer New

2 available
1 - 2 w.days
£215.34 Exc. VAT
£258.41 Inc. VAT

Direct from Manufacturer

Available on back order
4 - 6 W.Weeks
£142.07 Exc. VAT
£170.48 Inc. VAT

Environmental

Resistance to Vibrations acc. to IEC 60068-2-6 0.1 mm or 1 g - 20 cycles at 5…150…5 Hz
Ambient Temperature -25...55 °C
Pollution Degree 2
Environmental Information Refer to RoHS
Degree of Protection IP2X
Ambient Air Temperature Operation -25...55 °C
RoHS Status Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Resistance to Shock acc. to IEC 60068-2-27 25g 2 shocks 13 ms
Conflict Minerals Reporting Template (CMRT) 9AKK108468A3363
REACH Declaration 9AKK108467A9482
RoHS Information 9AKK106713A5602

Technical

Power Supply Connection Arbitrary
Rated Impulse Withstand Voltage (Uimp) 4 kV
Type of Residual Current AC type
Mounting Type DIN-Rail
Electrical Endurance 10000 cycle
Rated Residual Current 100 mA
Options Provided
Accessories Available Yes
Maximum Surge Current 0.25 kA
Leakage Current Type AC
Number of Poles 2
Operating Characteristic Instantaneous
Rated Conditional Short-Circuit Current (Inc) 10 kA
Rated Insulation Voltage (Ui) 500 V
Rated Operational Voltage 230 V
Rated Current (In) 100 A
Standards IEC/EN 61008UL 1053
Rated Voltage (Ur) 230 V
Rated Service Short-Circuit Breaking Capacity (Ics) 1 kA
Power Loss at Rated Operating Conditions per Pole 6.5 W
Connecting Capacity Busbar 10 mm²Rigid 35 ... 35 mm²Flexible 35 ... 35 mm²
Rated Frequency (f) 50 … 60 Hz
Rated Cross-Section 4 - Multi-Wired 0...35 mm²1 - Solid-Core 35...35 mm²

Classifications

Object Classification Code F
ETIM 9 EC000003 - Residual current circuit breaker (RCCB)
WEEE Category 5. Small Equipment (No External Dimension More Than 50 cm)
eClass V11.0 : 27142201
WEEE B2C / B2B Business To Consumer
CN8 85363030
EPLAN Function Definition Ground fault current circuit-breaker / Ground fault current circuit breakers, 4 connection points / Ground fault current circuit breaker, two-pole 1/2 2/1 3/4 4/3

Ordering

Package Level 1 Gross Weight 0.235 kg
Minimum Order Quantity 1 piece
Package Level 1 Units box 1 piece

Circular Value

Sustainable Material Content 0 %
Circular Design Principles Recyclability Rate Design for Closing Resource Loops - Standard EN45555 - 52,5 %
End of Life Instructions 9AKK108468A4361

Dimensions

Width in Number of Modular Spacings 2
Product Net Depth / Length 0.069 m
Built-In Depth (t2) 69 mm
Product Net Width 0.035 m
Product Net Height 0.085 m
Product Net Weight 0.200 kg

Installation

Instructions and Manuals 9AKK107991A6127

Eco Transparency

Environmental Product Declaration - EPD 9AKK108467A3700

Technical UL/CSA

Maximum Operating Voltage UL/CSA 277 V AC
Short-Circuit Current Rating (SCCR) 100 mA