This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

ABB

2CSF204001R1630

2CSF204001R1630 ABB

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 2CSF204001R1630 ABB

2CSF204001R1630 ABB - F204 AC-63/0.03 Residual Current Circuit Breaker 4P AC type 30 mA

Extended Description for 2CSF204001R1630 ABB

2CSF204001R1630 ABB - F204 AC-63/0.03 Residual Current Circuit Breaker 4P Type AC 30 mA

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Available on back order
4 - 6 W.Weeks
£69.83 Exc. VAT
£83.80 Inc. VAT

Technical

Rated Residual Current 30 mA
Type of Residual Current AC type
Rated Service Short-Circuit Breaking Capacity (Ics) 1 kA
Rated Operational Voltage 230 / 400 V AC
Rated Voltage (Ur) 230/400 V
Rated Current (In) 63 A
Rated Frequency (f) 50 … 60 Hz
Mounting Type DIN-Rail
Position of Neutral Terminals Right
Standards IEC/EN 61008UL 1053
Accessories Available Yes
Rated Conditional Short-Circuit Current (Inc) 10 kA
Operating Characteristic Instantaneous
Options Provided
Maximum Surge Current 0.25 kA
Rated Insulation Voltage (Ui) 500 V
Number of Poles 4
Rated Cross-Section 4 - Multi-Wired 0...25 mm²1 - Solid-Core 25...25 mm²
Leakage Current Type AC
Power Supply Connection Arbitrary
Connecting Capacity Busbar 10 mm²Rigid 25 ... 25 mm²Flexible 25 ... 25 mm²
Power Loss at Rated Operating Conditions per Pole 4.4 W
Electrical Endurance 10000 cycle
Rated Impulse Withstand Voltage (Uimp) 4 kV

Technical UL/CSA

Maximum Operating Voltage UL/CSA 480Y / 277 V AC
Short-Circuit Current Rating (SCCR) 30 mA

Dimensions

Built-In Depth (t2) 69 mm
Product Net Width 0.070 m
Product Net Height 0.085 m
Product Net Weight 0.360 kg
Width in Number of Modular Spacings 4
Product Net Depth / Length 0.069 m

Eco Transparency

Environmental Product Declaration - EPD 9AKK108467A3700

Circular Value

End of Life Instructions 9AKK108468A4361
Circular Design Principles Recyclability Rate Design for Closing Resource Loops - Standard EN45555 - 52,5 %
Sustainable Material Content 0 %

Environmental

REACH Declaration 9AKK108467A9482
Environmental Information Refer to RoHS
Degree of Protection IP2X
Resistance to Shock acc. to IEC 60068-2-27 25g 2 shocks 13 ms
Ambient Temperature -25...55 °C
RoHS Information 9AKK106713A5602
Pollution Degree 2
Conflict Minerals Reporting Template (CMRT) 9AKK108468A3363
RoHS Status Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Resistance to Vibrations acc. to IEC 60068-2-6 0.1 mm or 1 g - 20 cycles at 5…150…5 Hz
Ambient Air Temperature Operation -25...55 °C

Classifications

WEEE Category 5. Small Equipment (No External Dimension More Than 50 cm)
EPLAN Function Definition Ground fault current circuit-breaker / Ground fault current circuit breakers, 8 connection points / Ground fault current circuit breaker, four-pole 1_2_3_4_5_6_N_N.
Object Classification Code F
eClass V11.0 : 27142201
WEEE B2C / B2B Business To Consumer
CN8 85363030
ETIM 9 EC000003 - Residual current circuit breaker (RCCB)

Ordering

Package Level 1 Gross Weight 0.415 kg
Package Level 1 Units box 1 piece
Minimum Order Quantity 1 piece

Installation

Instructions and Manuals 9AKK107991A6127

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible