This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

ABB

2CSF204001R1900

2CSF204001R1900 ABB

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 2CSF204001R1900 ABB

2CSF204001R1900 ABB - F204 AC-100/0.03 Residual Current Circuit Breaker 4P AC type 30 mA

Extended Description for 2CSF204001R1900 ABB

2CSF204001R1900 ABB - F204 AC-100/0.03 Residual Current Circuit Breaker 4P Type AC 30 mA

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Available on back order
4 - 6 W.Weeks
£102.81 Exc. VAT
£123.37 Inc. VAT

Environmental

Environmental Information Refer to RoHS
RoHS Information 9AKK106713A5602
Conflict Minerals Reporting Template (CMRT) 9AKK108468A3363
REACH Declaration 9AKK108467A9482
Ambient Air Temperature Operation -25...55 °C
Resistance to Vibrations acc. to IEC 60068-2-6 0.1 mm or 1 g - 20 cycles at 5…150…5 Hz
Degree of Protection IP2X
Pollution Degree 2
RoHS Status Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Resistance to Shock acc. to IEC 60068-2-27 25g 2 shocks 13 ms
Ambient Temperature -25...55 °C

Eco Transparency

Environmental Product Declaration - EPD 9AKK108467A3700

Technical

Rated Voltage (Ur) 230/400 V
Rated Impulse Withstand Voltage (Uimp) 4 kV
Power Loss at Rated Operating Conditions per Pole 8.2 W
Options Provided
Maximum Surge Current 0.25 kA
Rated Cross-Section 4 - Multi-Wired 0...35 mm²1 - Solid-Core 35...35 mm²
Rated Insulation Voltage (Ui) 500 V
Rated Operational Voltage 230 / 400 V AC
Operating Characteristic Instantaneous
Rated Service Short-Circuit Breaking Capacity (Ics) 1 kA
Electrical Endurance 10000 cycle
Rated Conditional Short-Circuit Current (Inc) 10 kA
Type of Residual Current AC type
Number of Poles 4
Connecting Capacity Busbar 10 mm²Rigid 35 ... 35 mm²Flexible 35 ... 35 mm²
Leakage Current Type AC
Standards IEC/EN 61008UL 1053
Rated Current (In) 100 A
Rated Residual Current 30 mA
Rated Frequency (f) 50 … 60 Hz
Accessories Available Yes
Position of Neutral Terminals Right
Power Supply Connection Arbitrary
Mounting Type DIN-Rail

Dimensions

Built-In Depth (t2) 69 mm
Width in Number of Modular Spacings 4
Product Net Weight 0.380 kg
Product Net Height 0.085 m
Product Net Depth / Length 0.069 m
Product Net Width 0.070 m

Classifications

Object Classification Code F
WEEE B2C / B2B Business To Consumer
CN8 85363030
WEEE Category 5. Small Equipment (No External Dimension More Than 50 cm)
eClass V11.0 : 27142201
EPLAN Function Definition Ground fault current circuit-breaker / Ground fault current circuit breakers, 8 connection points / Ground fault current circuit breaker, four-pole 1_2_3_4_5_6_N_N.
ETIM 9 EC000003 - Residual current circuit breaker (RCCB)

Installation

Instructions and Manuals 9AKK107991A6127

Technical UL/CSA

Maximum Operating Voltage UL/CSA 480Y / 277 V AC
Short-Circuit Current Rating (SCCR) 30 mA

Circular Value

Circular Design Principles Recyclability Rate Design for Closing Resource Loops - Standard EN45555 - 52,5 %
Sustainable Material Content 0 %
End of Life Instructions 9AKK108468A4361

Ordering

Package Level 1 Units box 1 piece
Package Level 1 Gross Weight 0.415 kg
Minimum Order Quantity 1 piece