This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Allen Bradley

509-AAH-XXX-6P

Allen Bradley

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 509-AAH-XXX-6P Allen Bradley

509-AAH-XXX-6P Allen Bradley - NEMA Size 0 Non-Reversing Starter

Extended Description for 509-AAH-XXX-6P Allen Bradley

509-AAH-XXX-6P Allen Bradley - NEMA Full Voltage Non-Reversing Starter,SIZE 0,200-208V 60Hz,Type 1 General Purpose , Provision for Mounting an Overload Relay (field installation)

Free Delivery to UK Mainland on orders over £25

Product Detail

Hazardous Location No
Supply Voltage 208V 60Hz
Phases 3 Phase
Horsepower 3 HP
NEMA Size NEMA 0
Enclosure Code Type 1 General Purpose
Control Voltage 110/120V 50/60 Hz
Overload Relay Type Provision for Mounting an Overload Relay (field installation)
Full Load Amps Provision for Mounting an Overload Relay (field installation)
Factory Installed Modifications Transformer, w/2 Prim & 1 Sec Fuse
Enclosure Size [length x width x depth] 15 x 10 x 6 in.
Overload Relay Selection These products are intended for field installation of Bulletin 592 eutectic or solid state overload relays. They ship in a starter carton with provisions for mounting the overload relay (includes a starter mounting plate, screws/bolts and instructions)
Load Voltage 115…575 (V)
Continuous Current Rating 18 (A)
Service Limit Current Rating 21 (A)
Maximum Hp Rating (Non-plugging and non-jogging duty) Single-Phase - (Hp)
Maximum Hp Rating (Non-plugging and non-jogging duty) Three-Phase 5 (Hp)
Maximum Circuit Closing Inrush Current, Peak Including Offset 140 (A)
Mechanical Life 10 (Millions of Operations)
Maximum Number of Auxiliary Contacts 8
Pick-up Operating Time (Average) 21 (ms)
Drop-out Operating Time (Average) 16 (ms)
Wire size for Power Terminals 14…10 (AWG)
Required Torque 20 (lb•in)
Type of Power Terminal Saddle or Wire Clamps
Operating Position Vertical
Temperature Range -13…+131°F(-25…+55°C)
Altitude 10,000 (feet before derating)
Corrosion-Resistance All metal parts are treated for corrosion-resistance

Replacement Parts

Catalog Number CB-236
Description Coil,120V/60HZ 110V/50HZ For Starter Or Contactor
Quantity 1
Catalog Number 500F-AOD930
Description 500F, 500FC NEMA AC/DC Contactor,Motor Loads,Feed-Through ,SIZE 0, Open, 115-120V 60Hz, 3 Power Poles, Yes , 18 , 110/120V 50/60 Hz ,
Quantity 1
Additional Information NEMA Contactor and Starter Specification
Catalog Number 1497-HD80
Description Control Circuit Transformer 80 VA, 208V 60Hz Prim. / 120V 60Hz Sec.
Quantity 1
Additional Information Control Circuit Transformers (rockwellautomation.com)

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible