This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Allen Bradley

509-CJB-3-4R-6P-900

Allen Bradley

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 509-CJB-3-4R-6P-900 Allen Bradley

509-CJB-3-4R-6P-900 Allen Bradley - NEMA Size 2 Non-Reversing Starter

Extended Description for 509-CJB-3-4R-6P-900 Allen Bradley

509-CJB-3-4R-6P-900 Allen Bradley - NEMA Full Voltage Non-Reversing Starter,SIZE 2,460-480V 60Hz,Type 3R/4/12, Rainproof, Dusttight Industrial Use Enclosure, with Eutectic Alloy Overload Relay

Free Delivery to UK Mainland on orders over £25

Product Detail

Hazardous Location No
Phases 3 Phase
NEMA Size NEMA 2
Enclosure Code Type 3R/4/12 Rainproof, Dusttight Industrial Use
Control Voltage 110/120V 50/60 Hz
Overload Relay Type Eutectic Alloy
Full Load Amps Eutectic Overload - Select a heater element based on trip class and Motor FLA
Factory Installed Modifications HAND-OFF-AUTO Selector SwitchPilot LightsTransformer, w/2 Prim & 1 Sec FuseAuxiliary Contact (On Starter)
Enclosure Size [length x width x depth] 18 x 14 x 6 in.
Load Voltage 115…575 (V)
Continuous Current Rating 45 (A)
Service Limit Current Rating 52 (A)
Maximum Hp Rating (Non-plugging and non-jogging duty) Single-Phase - (Hp)
Maximum Hp Rating (Non-plugging and non-jogging duty) Three-Phase 25 (Hp)
Maximum Circuit Closing Inrush Current, Peak Including Offset 483 (A)
Mechanical Life 10 (Millions of Operations)
Maximum Number of Auxiliary Contacts 8
Pick-up Operating Time (Average) 27 (ms)
Drop-out Operating Time (Average) 1320 (ms)
Wire size for Power Terminals 14…4 (AWG)
Required Torque 45 (lb•in)
Type of Power Terminal Pressure Terminals
Operating Position Vertical
Temperature Range -13…+149°F(-25…+65°C)
Altitude 10,000 (feet before derating)
Corrosion-Resistance All metal parts are treated for corrosion-resistance

Replacement Parts

Catalog Number CC-236
Description Coil,115/120V 60HZ For Starter Or Contactor
Quantity 1
Catalog Number 500F-COD930
Description 500F, 500FC NEMA AC/DC Contactor,Motor Loads,Feed-Through ,SIZE 2, Open, 115-120V 60Hz, 3 Power Poles, Yes , 45 , 110/120V 50/60 Hz ,
Quantity 1
Additional Information NEMA Contactor and Starter Specification
Catalog Number 592-EUTC
Description NEMA Eutectic Alloy Overload Relay, Manual Reset, 62A, N.C. Contact
Quantity 1
Catalog Number 1497-BD80
Description Control Circuit Transformer 80 VA,
Quantity 1
Additional Information Control Circuit Transformers (rockwellautomation.com)
Catalog Number 599-PLF-120R
Description Pilot Light, Red, LED, 30mm, Type 4/12, 120V
Quantity 1
Additional Information 30 mm Push Button Specifications Technical Data (rockwellautomation.com)