This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Allen Bradley

512-BAB-1L-4R-6P-24R

Allen Bradley

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 512-BAB-1L-4R-6P-24R Allen Bradley

512-BAB-1L-4R-6P-24R Allen Bradley - NEMA Combination Starter Disconnect

Extended Description for 512-BAB-1L-4R-6P-24R Allen Bradley

512-BAB-1L-4R-6P-24R Allen Bradley - NEMA Combination Starter, Disconnect Type, NEMA 1, 480 Volts (B), Type 1 - Enclosure Code "A"

Free Delivery to UK Mainland on orders over £25

Product Detail

Current Product Selection Availability (may change based on options selected below) Catalog is configured at order entry
Please Note Preferred Availability options are available in blue below Standard Options are available in black below Engineered-To-Order (ETO) options are available in purple below (Lead-Time Based on Options)
Factory or User Assembled? Factory Assembled
Line Voltage 460V 60Hz
NEMA Size NEMA 1
Enclosure Type 1 - Enclosure Code "A"
Control Voltage 120V 60Hz
Disconnect Type Fusible
Fuse Clips 30A Class R
Overload Relay Eutectic Alloy
Full Load Amps Eutectic Overload
Factory Installed Modifications Transformer, w/2 Prim & 1 Sec FusePilot LightsIlluminated Start-Stop Push Button
Enclosure Size [length x width x depth] 27 x 10 x 8 in.
Continuous VA (Transformer Rating) 80
NC Aux. Contact on starter required for Illuminated Start-Stop Push Button Note: One NC contact is supplied and is used for the Illuminated Start-Stop Push Button.
Load Voltage 115…575 (V)
Continuous Current Rating 27 (A)
Service Limit Current Rating 32 (A)
Maximum Hp Rating (Non-plugging and non-jogging duty) Single-Phase - (Hp)
Maximum Hp Rating (Non-plugging and non-jogging duty) Three-Phase 10 (Hp)
Maximum Circuit Closing Inrush Current, Peak Including Offset 288 (A)
Mechanical Life 10 (Millions of Operations)
Maximum Number of Auxiliary Contacts 8
Pick-up Operating Time (Average) 22 (ms)
Drop-out Operating Time (Average) 14 (ms)
Wire size for Power Terminals 14…8 (AWG)
Required Torque 20 (lb•in)
Type of Power Terminal Saddle or Wire Clamps
Operating Position Vertical
Temperature Range -13…+149°F(-25…+65°C)
Altitude 10,000 (feet before derating)
Corrosion-Resistance All metal parts are treated for corrosion-resistance

Replacement Parts

Catalog Number 500F-BOD930
Description 500F, 500FC NEMA AC/DC Contactor,Motor Loads,Feed-Through ,SIZE 1, Open, 115-120V 60Hz, 3 Power Poles, Yes , 27 , 110/120V 50/60 Hz ,
Quantity 1
Additional Information NEMA Contactor and Starter Specification
Catalog Number 592-EUTB
Description NEMA Eutectic Alloy Overload Relay, Manual Reset, 40A, N.C. Contact
Quantity 1
Catalog Number 1497-BD80
Description Control Circuit Transformer 80 VA,
Quantity 1
Additional Information Control Circuit Transformers (rockwellautomation.com)
Catalog Number 599-PLF-120R
Description Pilot Light, Red, LED, 30mm, Type 4/12, 120V
Quantity 1
Additional Information 30 mm Push Button Specifications Technical Data (rockwellautomation.com)