Allen Bradley

512-EFB-A2M-6P-27R-901

Allen Bradley

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 512-EFB-A2M-6P-27R-901 Allen Bradley

512-EFB-A2M-6P-27R-901 Allen Bradley - NEMA Combination Starter Disconnect

Extended Description for 512-EFB-A2M-6P-27R-901 Allen Bradley

512-EFB-A2M-6P-27R-901 Allen Bradley - NEMA Combination Starter, Disconnect Type, NEMA 4, 480 Volts (B), Type 3R/4/12 - Enclosure Code "F"

Free Delivery to UK Mainland on orders over £25

Product Detail

Current Product Selection Availability (may change based on options selected below) Catalog is configured at order entry
Please Note Preferred Availability options are available in blue below Standard Options are available in black below Engineered-To-Order (ETO) options are available in purple below (Lead-Time Based on Options)
Factory or User Assembled? Factory Assembled
Line Voltage 460V 60Hz
NEMA Size NEMA 4
Enclosure Type 3R/4/12 - Enclosure Code "F"
Control Voltage 120V 60Hz
Disconnect Type Fusible
Fuse Clips 200A Class R
Overload Relay E100 Solid State Overload
Full Load Amps E100, Trip Class 20, 30-150A
Factory Installed Modifications Auxiliary Contact (On Starter OR Disconnect OR Breaker)Transformer, w/2 Prim & 1 Sec Fuse
Enclosure Size [length x width x depth] 50 x 22 x 11 in.
Continuous VA (Transformer Rating) 250
Load Voltage 115…575 (V)
Continuous Current Rating 135 (A)
Service Limit Current Rating 156 (A)
Maximum Hp Rating (Non-plugging and non-jogging duty) Single-Phase - (Hp)
Maximum Hp Rating (Non-plugging and non-jogging duty) Three-Phase 75 (Hp)
Maximum Circuit Closing Inrush Current, Peak Including Offset 1581 (A)
Mechanical Life 5 (Millions of Operations)
Maximum Number of Auxiliary Contacts 8
Pick-up Operating Time (Average) 2 (ms)
Drop-out Operating Time (Average) 20 (ms)
Wire size for Power Terminals 6…4/0 (AWG)
Required Torque 275 (lb•in)
Type of Power Terminal Pressure Terminals
Operating Position Vertical
Temperature Range -13…+131°F(-25…+55°C)
Altitude 10,000 (feet before derating)
Corrosion-Resistance All metal parts are treated for corrosion-resistance

Replacement Parts

Catalog Number 500F-EOD930
Description 500F, 500FC NEMA AC/DC Contactor,Motor Loads,Feed-Through ,SIZE 4, Open, 115-120V 60Hz, 3 Power Poles, Yes , 135 , 110/120V 50/60 Hz ,
Quantity 1
Additional Information NEMA Contactor and Starter Specification
Catalog Number 592-EFJZ
Description Bulletin 592, E1 Plus Solid State Overload Relay, Automatic / Manual Reset, Mounts to NEMA Contactor
Quantity 1
Additional Information E100 Electronic Overload Relay Specifications (rockwellautomation.com)