Description for 513-BHA-1-38 Allen Bradley

513-BHA-1-38 Allen Bradley - NEMA Size 1 COMB Starter Circuit Breaker

Extended Description for 513-BHA-1-38 Allen Bradley

513-BHA-1-38 Allen Bradley - NEMA Combination Starter, Circuit Breaker Type, NEMA 1, 240 Volts (A), Type 3R, 7 & 9 Bolted - Enclosure Code "H"

Free Delivery to UK Mainland on orders over £25

Product Detail

Current Product Selection Availability (may change based on options selected below) Catalog is configured at order entry
Please Note Preferred availability options are available in blue below Standard Options are available in black below Engineered-To-Order (ETO) options are available in purple below (Lead-Time Based on Options)
Factory or User Assembled? Factory Assembled
Line Voltage 230V 60Hz
NEMA Size NEMA 1
Enclosure Type 3R, 7 & 9 Bolted - Enclosure Code "H"
Control Voltage 240V 60Hz
Horsepower Code 3 HP (Motor Protection)
Circuit Breaker Type Instantaneous Trip, Standard
Overload Relay Eutectic Alloy
Full Load Amps Eutectic Overload
Factory Installed Modifications START-STOP Push Button
Enclosure Size [length x width x depth] Unknown
Load Voltage 115…575 (V)
Continuous Current Rating 27 (A)
Service Limit Current Rating 32 (A)
Maximum Hp Rating (Non-plugging and non-jogging duty) Single-Phase 3 (Hp)
Maximum Hp Rating (Non-plugging and non-jogging duty) Three-Phase 7-1/2 (Hp)
Maximum Circuit Closing Inrush Current, Peak Including Offset 288 (A)
Mechanical Life 10 (Millions of Operations)
Maximum Number of Auxiliary Contacts 8
Pick-up Operating Time (Average) 22 (ms)
Drop-out Operating Time (Average) 14 (ms)
Wire size for Power Terminals 14…8 (AWG)
Required Torque 20 (lb•in)
Type of Power Terminal Saddle or Wire Clamps
Operating Position Vertical
Temperature Range -13…+149°F(-25…+65°C)
Altitude 10,000 (feet before derating)
Corrosion-Resistance All metal parts are treated for corrosion-resistance

Replacement Parts

Catalog Number 500F-BOD930
Description 500F, 500FC NEMA AC/DC Contactor,Motor Loads,Feed-Through ,SIZE 1, Open, 115-120V 60Hz, 3 Power Poles, Yes , 27 , 110/120V 50/60 Hz ,
Quantity 1
Additional Information NEMA Contactor and Starter Specification
Catalog Number 592-EUTB
Description NEMA Eutectic Alloy Overload Relay, Manual Reset, 40A, N.C. Contact
Quantity 1

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible