This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Omron

D4C-1302

D4C-1302 Omron

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for D4C-1302 Omron

D4C-1302 Omron - Omron Roller Plunger Limit Switch, IP67, SPDT, 5A Max

Free Delivery to UK Mainland on orders over £25

Manufacturer New

3 available
1 - 2 w.days
£110.84 Exc. VAT
£133.01 Inc. VAT

Ratings / Performance

Service life General type
Actuator 12 dia. * 5 Sintered stainless steel roller
Degree of protection IEC60529 (JEM): IP67
Contact form SPDT
Load General load
Ratings (DC): Inductive load Rated voltage: 30 VDC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Shock resistance (Malfunction) Contact opening is 1 ms Max. at the free position and the total travel position at 500 m/s2.
Ratings (DC): Non-Inductive load Rated voltage: 8 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Ratings (DC): Inductive load Rated voltage: 125 VDC / Inductive load: 0.4 A(NC) 0.4 A(NO) / Motor load: 0.05 A(NC) 0.05 A(NO)
Contact resistance (Measuring method is contact resistance meter.)
Shape/Structure General-purpose Limit switches
Shock resistance (Destruction) 1,000 m/s2
Electrical ratings 4 A at 30 VDC
Ratings (DC): Non-Inductive load Rated voltage: 30 VDC / Resistive load: 4 A(NC) 4 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Release Force (RF) Standard value Min. 4.41 N
Permissible operating speed 0.1 mm/s to 0.5 m/s
Operating mechanism Snap action
Ratings (AC): Inductive load Rated voltage: 125 VAC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 2.5 A(NC) 1.3 A(NO)
Ratings (DC): Non-Inductive load Rated voltage: 250 VDC / Resistive load: 0.2 A(NC) 0.2 A(NO) / Lamp load: 0.03 A(NC) 0.03 A(NO)
Dielectric strength Between live-metallic part and ground: 1500 V
Durability (Electrically) (Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH)
Durability (Mechanically) (Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH)
Ambient temperature Operating: -10 to 70 °C
Protective circuit Short-circuit protective device: 10 A fuse type gI or gG (IEC269)
Earth terminal With ground terminal
Insulation resistance Between live-metallic part and ground: 100 MΩ
Insulation resistance (at 500 VDC Megger)
Dielectric strength (50/60 Hz for 1 min)
Ratings (DC): Non-Inductive load Rated voltage: 125 VDC / Resistive load: 0.4 A(NC) 0.4 A(NO) / Lamp load: 0.05 A(NC) 0.05 A(NO)
Pre-Travel (PT) Standard value 1.8 mm Max.
Vibration resistance (Malfunction) Vibration frequency range: 10 to 55 Hz, Double amplitude: 1.5 mm, Contact opening: 1 ms Max. at the free position and the total travel position.
Contact resistance 400 mOhm Max. (Initial value) * Including the resistance of cable.
Dielectric strength Between each terminal of the same polarities: 1000 V
Contact configuration Single-Pole, Double-Throw type
Inrush current NO: 10 A
Mounting specification Front mounting
Electrical ratings 5 A at 250 VAC
Ratings (DC): Inductive load Rated voltage: 14 VDC / Inductive load: 4 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Ratings (AC): Non-Inductive load Rated voltage: 250 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1 A(NC) 0.5 A(NO)
Ratings (DC): Inductive load Rated voltage: 8 VDC / Inductive load: 5 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Insulation resistance Between each terminal and non-live-metallic part: 100 MΩ
Protective circuit Classification of protection against electric shock: Class I (with ground terminal)
Cable specifications Diameter: 7.6 mm
Operating Position (OP) Standard value 28.5 +/- 1 mm
Ratings (AC): Non-Inductive load Rated voltage: 125 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1.5 A(NC) 0.7 A(NO)
Durability (Mechanically) 10,000,000 operations Min. (No load)
Durability (Electrically) 200,000 operations Min. (Resistive load 5 A at 125 VAC)
Operating Force (OF) Standard value Max. 11.77 N
Frequency 50/60 Hz
Inrush current NC: 20 A
Ratings (DC): Non-Inductive load Rated voltage: 14 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Actuator Roller plunger
Cable specifications VCTF oil-resistant cable 4 cores (Cable length: 5 m)
Ambient humidity Operating: 35 to 95%
Dielectric strength Between each terminal and non-live-metallic part: 1500 V
Ratings (AC): Inductive load Rated voltage: 250 VAC / Inductive load: 2 A(NC) 2 A(NO) / Motor load: 1.5 A(NC) 0.8 A(NO)
Permissible operating frequency (Electrically) 30 operations / 1 minute Max.
Switching mechanism Self-reset mechanism
Ratings (DC): Inductive load Rated voltage: 250 VDC / Inductive load: 0.2 A(NC) 0.2 A(NO) / Motor load: 0.03 A(NC) 0.03 A(NO)
Pollution degree 3 (EN60947-5-1)
Movement Differential (MD) Standard value 0.2 mm Max.
Insulation resistance Between each terminal of the same polarities: 100 MΩ
Over-Travel (OT) Standard value 3 mm Min.
Permissible operating frequency (Mechanically) 120 operations / 1 minute Max.

Documentation

Downloads

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible