This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Omron

LY2 AC110/120

LY2 AC110/120 Omron

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for LY2 AC110/120 Omron

LY2 AC110/120 Omron - Standard type, Single, Plug-in, Coil ratings: 9.9mA 110 VAC, Output DPDT (10A 24V)

Extended Description for LY2 AC110/120 Omron

LY2 AC110/120 Omron - Omron Plug In Power Relay, 110 → 120V ac Coil, 10A Switching Current, DPDT

Free Delivery to UK Mainland on orders over £25

Ratings / Performance

Maximum switching power DC: 120 W (Inductive load (L/R = 7 ms))
Contact rated load 24 VDC 5 A (Inductive load (L/R = 7 ms))
Vibration resistance (Destruction) 10 to 55 to 10 Hz, 0.5-mm single amplitude 2 hours each in X, Y, and Z directions
Insulation resistance Between contacts of same polarity: JA:100 MΩ min. (at 500 VDC)
Endurance (Mechanical) 50000000 operations Min.
Shock resistance (Malfunction) 200 m/s**2
Insulation resistance Between coil and contacts: JA:100 MΩ min. (at 500 VDC)
Endurance (Electrical) 500000 operations Min.
Contact resistance Max. 50 mOhm, Measuring the voltage drop across the contacts by applying test voltage/current as 5 VDC 1 A
Operate voltage (Set voltage) 80 % max.
Coil ratings 110 VAC 9.9 mA (50 Hz) / 110 VAC 8.4 mA (60 Hz) / 120 VAC 10.8 mA (50 Hz) / 120 VAC 9.2 mA (60 Hz)
Maximum switching voltage 125 VDC (Resistive load)
Ambient_humidity (Operating) 5 to 85%RH (with no icing or condensation)
Failure rate 100 mA at 5 VDC (failure level: P Reference value)
Vibration resistance (Malfunction) 10 to 55 to 10 Hz, 0.5-mm single amplitude in each direction
Dielectric strength Between contacts of same polarity: 1000 V (Leakage current 3 mA 50/60 Hz 1 min)
Weight Approx.40 g
Contact material Contact body: Ag alloy
Contact rated load 110 V AC7.5 A (Inductive load (cos phi = 0.4))
Contact method Single
Release voltage (Reset voltage) 30 % Min.
Max. voltage 110 % (of rated voltage)
Terminal structure Plug-in
Protective structure Closed type (cover)
Contact rated load 110 V AC10 A (Resistive load (cos phi = 1))
Power consumption 0.9 to 1.1 VA (60 Hz)
Maximum switching power DC: 240 W (Resistive load)
Release time (Reset time) 25 ms
Maximum switching current DC: 10 A
Contact rated load 24 VDC 10 A (Resistive load)
Coil surge killer Not equipped
Maximum switching power AC: 825 VA (Inductive load (cos phi = 0.4))
Operating time (set time) 25 ms
Product classification Monostable relays
Contact type DPDT
Shock resistance (Destruction) 1000 m/s**2, 3 times each in directions
Maximum switching current AC: 10 A
Insulation resistance Between contacts of different polarity: JA:100 MΩ min. (at 500 VDC)
Product classification Standard type
Operating indicator Not equipped
Dielectric strength Between contacts of different polarity: 2000 V (Leakage current 3 mA 50/60 Hz 1 min)
Coil resistance 4430 Ω
Dielectric strength Between coil and contacts: 2000 V (Leakage current 3 mA 50/60 Hz 1 min)
Ambient temperature (Operating) -25 to 55 °C (with no icing or condensation)
Contact material Contact finish: Nothing
Maximum switching power AC: 1100 VA (Resistive load (cos phi = 1))
Maximum switching voltage 250 VAC (Resistive load (cos phi = 1))

Documentation

Downloads

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible