Description for 04031 Schneider Electric

04031 Schneider Electric - LINERGY DX 1P DIST.BLOCK 160A 4M 6HOLES

Extended Description for 04031 Schneider Electric

04031 Schneider Electric - Linergy DX distribution block for Prisma G.,It is compatibility with spacial enclosures.,The rated operational voltage is 690V AC.,The rated operational current is 160A.,It provides IPxx B degree of protection.,It provides 1 pole with anthracite grey (RAL 7016) surface treatment.,It could be connected on the tunnel type terminal and spring terminal by DIN rail mounting support.,It is suitbale for 2 total number of 18 mm modules and 3 pollution degree.,It provides 960 °C resistance to incandescent wire conforming to IEC 60695-2-11.,It is certified by ASEFA.,It is compliant with both IEC 61439-1 (inside Prisma), IEC 61439-2 (inside Prisma) and IEC 60947-7-1.,It is also compliant with Green Premium (RoHS/REACH).

Free Delivery to UK Mainland on orders over £25

Main

Range Linergy
range of product Linergy
product or component type Distribution block
Product name Linergy DX
Range compatibility Prisma Prisma G enclosure,Prisma Prisma P enclosure,Prisma Prisma PH enclosure,Prisma Prisma Pack 250 enclosure
Product compatibility Spacial enclosures
accessory / separate part category Current distribution accessory
IP degree of protection IPxx B

Complementary

mounting support DIN rail
Installed device Acti 9: fixed C120 with earth leakage protection - control: toggle,Acti 9: fixed C120 without earth leakage protection - control: toggle,Acti 9: fixed iC120 with earth leakage protection - control: toggle,Acti 9: fixed iC120 without earth leakage protection - control: toggle,ComPact: fixed INS40 - control: direct front rotary handle - vertical installation,ComPact: fixed INS63 - control: direct front rotary handle - vertical installation,ComPact: fixed INS100 - control: direct front rotary handle - vertical installation,ComPact: fixed INS125 - control: direct front rotary handle - vertical installation,ComPact: fixed INS160 - control: direct front rotary handle - vertical installation,FuPact: fixed ISFT160 - control: fuse carriers handle - vertical installation,FuPact: fixed ISFT100N - control: fuse carriers handle - vertical installation,Multi9: fixed NG125 with earth leakage protection - control: toggle,Multi9: fixed NG125 without earth leakage protection - control: toggle,Multi9: fixed NG125 NA - control: toggle,ComPact: fixed NG160 with earth leakage protection - control: toggle,ComPact: fixed NG160 without earth leakage protection - control: toggle,ComPact: fixed NG160 NA without earth leakage protection - control: toggle,FuPact: fixed INF100...160 - control: extended rotary handle - vertical installation,ComPact: fixed NSXm without earth leakage protection - control: toggle - vertical installation,ComPact: fixed NSXm without earth leakage protection - control: toggle - horizontal installation,ComPact: fixed NSXm without earth leakage protection - control: direct rotary handle - horizontal installation,ComPact: fixed NSXm with earth leakage protection - control: toggle - vertical installation,ComPact: fixed NSXm with earth leakage protection - control: toggle - horizontal installation
Poles description 1P
[Ue] rated operational voltage 690 V AC
[Ui] rated insulation voltage 750 V AC
[Uimp] rated impulse withstand voltage 8 kV
[Ie] rated operational current 160 A
[In] rated current 160 A at 40 °C
[Icw] rated short-time withstand current 5.5 kA for 1 s
[Ipk] rated peak withstand current 24 kA
I²t on activation 30250000 A².s
Connections - terminals Supply: tunnel type terminal70 mm² (flexible) ,Supply: tunnel type terminal70 mm² (rigid) ,Distribution: spring terminal, 6 x 6…16 mm² (flexible) ,Distribution: spring terminal, 6 x 6…16 mm² (rigid)
9 mm pitches 4
Total number of 18 mm modules 2
Height 95 mm
Width 36 mm
Depth 70 mm
net weight 0.1 kg
Colour Anthracite grey (RAL 7016)

Environment

Pollution degree 3
Resistance to incandescent wire 960 °C conforming to IEC 60695-2-11
Standards IEC 61439-1, inside Prisma,IEC 61439-2, inside Prisma,IEC 60947-7-1
Product certifications ASEFA

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1

Contractual warranty

Warranty 18 months

Documentation

Product Datasheet

User guide

Instruction sheet

Catalogue

CAD

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible