This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Schneider Electric

28570

28570 Schneider Electric

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 28570 Schneider Electric

28570 Schneider Electric - Earth-leakage relay RHU - 0.03..30 A - 0..5 s - 48 V

Free Delivery to UK Mainland on orders over £25

Main

Range Vigirex
Device short name RHU
product or component type Residual current protection relay
Relay application Residual current protection relay
mounting support Panel
Earth-leakage protection class Class A,Class AC
Type of setting Internal bus,Keypad
Earth-leakage time delay Adjustable 0…4.5 s for 0.03…30 A,Instantaneous for 0.03 A
Current sensors compatibility Vigirex TOA earth leakage current sensor,Vigirex A earth leakage current sensor,Vigirex L earth leakage current sensor
[Ithe] conventional enclosed thermal current 8 A
Minimum load 10 mA at 12 V
[Us] rated supply voltage 48 V AC 50/60 Hz
Power consumption in VA 8 VA
Monitored distribution system 1000 V - AC at 50/60 Hz (maximum) ,1000 V - AC at 400 Hz (maximum)
Earthing system IT,TT,TN-S

Complementary

Test function Remote test,Remote test (via communication),Local
Monitoring Electronics (continuous) ,Power supply (continuous) ,Relay/sensor link (continuous)
Signal contacts composition 1 NO
Type of measurement Earth fault current internal measurement, range: 80...100 %, accuracy: +/- 10 %
Refresh time 2 s
Communication service Supervision via internal bus
Tamperproof of settings Protected by sealable cover
Connections - terminals Alarm circuit: terminal block cable(s) 0.2…2.5 mm² flexible AWG 22...AWG 12,Alarm circuit: terminal block cable(s) 0.2…2.5 mm² rigid AWG 22...AWG 12,Alarm circuit: terminal block cable(s) 0.25…2.5 mm² flexible AWG 22...AWG 12,Auxiliary power supply: terminal block cable(s) 0.2…2.5 mm² flexible AWG 22...AWG 12,Auxiliary power supply: terminal block cable(s) 0.2…2.5 mm² rigid AWG 22...AWG 12,Auxiliary power supply: terminal block cable(s) 0.25…2.5 mm² flexible AWG 22...AWG 12,Communication bus: terminal block cable(s) 0.2…2.5 mm² flexible AWG 22...AWG 12,Communication bus: terminal block cable(s) 0.2…2.5 mm² rigid AWG 22...AWG 12,Communication bus: terminal block cable(s) 0.25…2.5 mm² flexible AWG 22...AWG 12,Fault: terminal block cable(s) 0.2…2.5 mm² flexible AWG 22...AWG 12,Fault: terminal block cable(s) 0.2…2.5 mm² rigid AWG 22...AWG 12,Fault: terminal block cable(s) 0.25…2.5 mm² flexible AWG 22...AWG 12,Relay test and fault reset: terminal block cable(s) 0.2…2.5 mm² flexible AWG 22...AWG 12,Relay test and fault reset: terminal block cable(s) 0.2…2.5 mm² rigid AWG 22...AWG 12,Relay test and fault reset: terminal block cable(s) 0.25…2.5 mm² flexible AWG 22...AWG 12,Sensor: terminal block cable(s) 0.2…2.5 mm² flexible AWG 22...AWG 12,Sensor: terminal block cable(s) 0.2…2.5 mm² rigid AWG 22...AWG 12,Sensor: terminal block cable(s) 0.25…2.5 mm² flexible AWG 22...AWG 12,Voltage presence: terminal block cable(s) 0.2…2.5 mm² flexible AWG 22...AWG 12,Voltage presence: terminal block cable(s) 0.2…2.5 mm² rigid AWG 22...AWG 12,Voltage presence: terminal block cable(s) 0.25…2.5 mm² flexible AWG 22...AWG 12
Wire stripping length Alarm circuit: 6 mm,Auxiliary power supply: 6 mm,Communication bus: 6 mm,Fault: 6 mm,Relay test and fault reset: 6 mm,Sensor: 6 mm,Voltage presence: 6 mm
Tightening torque Alarm circuit: 0.5 N.m,Auxiliary power supply: 0.5 N.m,Fault: 0.5 N.m,Relay test and fault reset: 0.5 N.m,Sensor: 0.5 N.m,Voltage presence: 0.5 N.m
Width 72 mm
Height 72 mm
Depth 116 mm
net weight 0.3 kg
Mechanical robustness Fire resistance conforming to IEC 60695-2-1,IK protection 2 joules: IK07 conforming to EN 50102,IP protection: IP20 conforming to IEC 60529,IP protection: IP30 conforming to IEC 60529,IP protection: IP40 conforming to IEC 60529,Vibrations 13.2...100 Hz: 0.7 g,Vibrations 2...13.2 Hz: +/- 1 mm

Environment

Overvoltage category IV
Electrical shock protection class Class II on communication output,Class II on front face
Electromagnetic compatibility Conducted and radiated emissions: , B, conforming to CISPR 11,Conducted radio-frequency immunity test: , 3, conforming to IEC 61000-4-6,Electrostatic discharge immunity test: , 4, conforming to IEC 61000-4-2,High-energy conducted susceptibility: , 4, conforming to IEC 61000-4-5,Low-energy conducted susceptibility: , 4, conforming to IEC 61000-4-4,Radiated susceptibility: , 3, conforming to IEC 61000-4-3
Relative humidity 95 % at 55 °C
Pollution degree 3 conforming to IEC 60664-1
Ambient air temperature for operation -25…55 °C
Ambient air temperature for storage -40…85 °C

Contractual warranty

Warranty 18 months

Documentation

Product Datasheet

CAD

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible