This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Schneider Electric

31334

31334 Schneider Electric

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 31334 Schneider Electric

31334 Schneider Electric - switch disconnector, Compact INS1250 , 1250 A, standard version with black rotary handle, 3 poles

Extended Description for 31334 Schneider Electric

31334 Schneider Electric - This Compact INS1250 is a 3 poles non-automatic switch-disconnector with black rotary handle.,It is suitable for isolation with positive contact indication, as defined by IEC 60947-1 and IEC60947-3 standards.,The operational current is 1250A at 415VAC in categories AC21A, AC22A and AC23A.,The rated voltage is 690VAC 50/60Hz or 250VDC.,The black rotary handle is designed to offer easy operation and high performance in interruption of currents.,Compact INS1250 is a class II insulation level front-face device as per IEC 60664 standard.

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Available on back order
4 - 6 W.Weeks
£902.08 Exc. VAT
£1,082.50 Inc. VAT

Main

Range ComPact
Product name ComPacT INS
product or component type Switch disconnector
Poles description 3P
Network type AC,DC
Network frequency 50/60 Hz
[Ie] rated operational current AC-21A: 1250 A AC 50/60 Hz 220/240 V,AC-21A: 1250 A AC 50/60 Hz 380/415 V,AC-21A: 1250 A AC 50/60 Hz 440/480 V,AC-21A: 1250 A AC 50/60 Hz 480 V NEMA,AC-21A: 1250 A AC 50/60 Hz 500/525 V,AC-21A: 1250 A AC 50/60 Hz 660/690 V,AC-22A: 1250 A AC 50/60 Hz 220/240 V,AC-22A: 1250 A AC 50/60 Hz 380/415 V,AC-22A: 1250 A AC 50/60 Hz 440/480 V,AC-22A: 1250 A AC 50/60 Hz 480 V NEMA,AC-22A: 1250 A AC 50/60 Hz 500/525 V,AC-22A: 1250 A AC 50/60 Hz 660/690 V,AC-23A: 1250 A AC 50/60 Hz 220/240 V,AC-23A: 1250 A AC 50/60 Hz 380/415 V,AC-23A: 1250 A AC 50/60 Hz 440/480 V,AC-23A: 1250 A AC 50/60 Hz 480 V NEMA,AC-23A: 1250 A AC 50/60 Hz 500/525 V,AC-23A: 1250 A AC 50/60 Hz 660/690 V,DC-21A: 1250 A DC 125 V 2 poles in series,DC-22A: 1250 A DC 125 V 2 poles in series,DC-23A: 1250 A DC 125 V 2 poles in series
[Ui] rated insulation voltage 1000 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 12 kV
[Ith] conventional free air thermal current 1250 A at 60 °C
[Icm] rated short-circuit making capacity 75 kA switch-disconnector alone 690 V AC at 50/60 Hz,330 kA with upstream protection circuit breaker 690 V AC at 50/60 Hz
[Ue] rated operational voltage 125 V DC,690 V AC 50/60 Hz
Suitability for isolation Yes
Contact position indicator Yes
Visible break No
Pollution degree 3

Complementary

Control type Direct front rotary handle
Handle colour Black
mounting mode Fixed
mounting support Rail,Plate
Upside connection Front
Downside connection Front
Maximum power AC-23: 400 kW at 220/240 V AC 50/60 Hz,AC-23: 710 kW at 380/400 V AC 50/60 Hz,AC-23: 800 kW at 415 V AC 50/60 Hz,AC-23: 900 kW at 500/525 V AC 50/60 Hz
Rated duty Uninterrupted
Intermittent duty class Class 120 - 60 %
[Icw] rated short-time withstand current 10 kA during 20 s conforming to IEC 60947-3,20 kA during 3 s conforming to IEC 60947-3,35 kA during 1 s conforming to IEC 60947-3,42 kA during 0.8 s conforming to IEC 60947-3,50 kA during 0.5 s conforming to IEC 60947-3,8 kA during 30 s conforming to IEC 60947-3
Mechanical durability 3000 cycles
Electrical durability AC-21A: 500 cycles 220/240 V AC 50/60 Hz,AC-21A: 500 cycles 380/415 V AC 50/60 Hz,AC-21A: 500 cycles 440/480 V AC 50/60 Hz,AC-21A: 500 cycles 480 V AC 50/60 Hz conforming to NEMA,AC-21A: 500 cycles 500/525 V AC 50/60 Hz,AC-21A: 500 cycles 660/690 V AC 50/60 Hz,AC-22A: 500 cycles 220/240 V AC 50/60 Hz,AC-22A: 500 cycles 380/415 V AC 50/60 Hz,AC-22A: 500 cycles 440/480 V AC 50/60 Hz,AC-22A: 500 cycles 480 V AC 50/60 Hz conforming to NEMA,AC-22A: 500 cycles 500/525 V AC 50/60 Hz,AC-22A: 500 cycles 660/690 V AC 50/60 Hz,AC-23A: 500 cycles 220/240 V AC 50/60 Hz,AC-23A: 500 cycles 380/415 V AC 50/60 Hz,AC-23A: 500 cycles 440/480 V AC 50/60 Hz,AC-23A: 500 cycles 480 V AC 50/60 Hz conforming to NEMA,AC-23A: 500 cycles 500/525 V AC 50/60 Hz,AC-23A: 500 cycles 660/690 V AC 50/60 Hz,DC-21A: 500 cycles 125 V DC 2 poles in series,DC-22A: 500 cycles 125 V DC 2 poles in series,DC-23A: 500 cycles 125 V DC 2 poles in series
Connection pitch 70 mm
Height 300 mm
Width 340 mm
Depth 146.5 mm
net weight 14 kg

Environment

Standards IEC 60947-3,IEC 60947-1
Product certifications KEMA-KEUR
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to EN 50102
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -50…85 °C

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 21.000 cm
Package 1 Width 33.500 cm
Package 1 Length 36.000 cm
Package 1 Weight 15.500 kg

Contractual warranty

Warranty 18 months

Documentation

Product Datasheet

Instruction sheet

Catalogue

CAD

Environmental disclosure

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible