Description for 50606 Schneider Electric

50606 Schneider Electric - insulation monitoring XL308 Vigilohm - 115..127 V AC 50/60 Hz - failsafe

Extended Description for 50606 Schneider Electric

50606 Schneider Electric - This device belongs to the Vigilohm range designed to monitor ungrounded/IT electrical networks at feeder level, in accordance to installation and products standards.,This insulation fault location is only possible when it is associated to XM300C series or XML308/316.,This device is dedicated to monitoring 8 feeders, AC, DC and ACDC, up to the toroid limit, 1000V.,It mesures the insulation resistance and leakage capacitance per feeder.,Configuration is set from the front of the device, through the function keys.,Settings are related to alarm thresholds.,It displays which feeder has an insulation fault.,The device can schedule auto-test, and a button can launch a on demand test.,In case the insulation resistance drops below the set threshold, an alarm is triggered thru the XL output relay and channel indicator light.,Once no fault is monitored, the alarm is cleared, the alarm relay is back to normal.,The device can be supplied by a 115V AC to 127V AC source with a tolérence of plus 10% or minus 15%.

Free Delivery to UK Mainland on orders over £25

Main

range of product Vigilohm
Device short name XL308
Type of measurement Local measurement
Signal contacts composition 2 C/O
Earthing system IT
Display type LED
Scale 0.1...999 kOhm
Number of channels 8
Fail safe feature With
[Us] rated supply voltage 115...127 V AC 50/60 Hz tolerance: - 15...10 %
Mounting position Horizontal mounting

Complementary

Signalling function Alarm,Insulation value display
Polling time 15 s
Test function Manual, self test
Breaking capacity 10 A at 24 V DC, L/R = 1 ms,0.45 A at 220 V DC, L/R = 1 ms,0.65 A at 120 V DC, L/R = 1 ms,2.5 A at 48 V DC, L/R = 1 ms,5 A at 230 V AC, cos phi = 0.7,3 A at 400 V AC, cos phi = 0.7
maximum power consumption in VA 30 VA
mounting mode Flush-mounted
mounting support Plate,Cubicle,Enclosure
Height 129 mm
Width 153 mm
Depth 213.5 mm
net weight 3.5 kg
Auxiliary connection terminal Tunnel type terminals 1.5 mm²

Environment

Dielectric strength 2500 V
Standards UTE C 63-080 class DLD/M,IEC 364 ch 4 and 5,IEC 61557-8,NF C 15-100 §413.4
Ambient air temperature for operation -5…55 °C
Ambient air temperature for storage -20…70 °C

Contractual warranty

Warranty 18 months

Documentation

Product Datasheet

User guide

Catalogue