This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Schneider Electric

A9A15220

A9A15220 Schneider Electric

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for A9A15220 Schneider Electric

A9A15220 Schneider Electric - modular safety transfomer iTR - 230 V 50..60 Hz - output 12..24 V - 40 VA

Extended Description for A9A15220 Schneider Electric

A9A15220 Schneider Electric - This Acti 9 iTR 40VA safety transformer allows to obtain a very low voltage 12VAC or 24VAC from a network 230VAC.,The transformer is safe meaning that primary and secondary circuits are perfectly insulated by each other.,The power supply is 40VA. The operating frequency is 50Hz or 60Hz.,The primary voltage is 230VAC +/-10%. The secondary voltage output is 12VAC or 24VAC +/-5%.,It is resistant to short-circuit currents thanks to the built-in-device.,The off load voltage is 14VAC for a 12VAC rated secondary voltage.,The off load voltage is 28VAC for a 24VAC rated secondary voltage.,It is a Class II device with terminal shield (optional).,The safety transformer should be mounted on DIN rail in vertical position only.,The width in 9mm pitches is 10. The weight is 1190g.,The degree of protection under IEC 60529 standard is IP20 with terminal shield.,The dimensions are (W) 90mm x (H) 89mm x (D) 60mm. The width in modules of 18mm is 5.,The operating temperature is -20°C to 55°C. The storage temperature is -25°C to 80°C.,This product complies with IEC/EN 61558-2-6 standard.

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Available on back order
4 - 6 W.Weeks
£48.86 Exc. VAT
£58.63 Inc. VAT

Main

Transformer type Safety transformer
Range Acti9
range of product Acti9
Product name Acti9 iTR
product or component type Transformer
Device short name iTR

Complementary

[Ue] rated operational voltage 230 V AC 50/60 Hz
Output voltage 12/24 V: +/-5 % on load,14/28 V: off load
Output short-circuit protection Built-in
Rated power in VA 40 VA
Temperature derating table 40 VA 35 °C,38 VA 40 °C,32 VA 50 °C,24 VA 55 °C,18 VA 60 °C
mounting mode Fixed
mounting support 35 mm symmetrical DIN rail
9 mm pitches 10
Height 89 mm
Width 90 mm
Depth 60 mm
colour White
Auxiliary connection terminal Tunnel type terminals 4 mm²

Environment

Standards EN 60742,EN 61558-2-6,IEC 61558-2-6
Product certifications NF
Overvoltage category Class II with terminal shields in option
Ambient air temperature for operation -20…55 °C
Ambient air temperature for storage -25…80 °C

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 7.000 cm
Package 1 Width 9.500 cm
Package 1 Length 9.500 cm
Package 1 Weight 1.202 kg
Unit Type of Package 2 S02
Number of Units in Package 2 8
Package 2 Height 15.000 cm
Package 2 Width 30.000 cm
Package 2 Length 40.000 cm
Package 2 Weight 9.885 kg
Unit Type of Package 3 P12
Number of Units in Package 3 64
Package 3 Height 45.000 cm
Package 3 Width 80.000 cm
Package 3 Length 120.000 cm
Package 3 Weight 90.080 kg

Contractual warranty

Warranty 18 months

Documentation

Product Datasheet

Instruction sheet

CAD

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible