Description for A9D67416 Schneider Electric

A9D67416 Schneider Electric - Residual current breaker with overcurrent protection (RCBO), Acti9 iC60, 4P, 16A, C curve, 6000A/6kA, A type, 30mA

Extended Description for A9D67416 Schneider Electric

A9D67416 Schneider Electric - This Acti9 iC60 is a modular residual current breaker with overcurrent protection (RCBO).,It is a 4P RCBO with 4 protected poles, rated current is 16A, and operating voltage is 380VAC to 415VAC.,The earth leakage protection class is A type with a sensitivity of 30mA. The earth-leakage protection time delay is instantaneous.,Breaking capacity at 280VAC to 415VAC is 6000A according to EN/IEC 61009-2-1 and 6kA according to EN/IEC 60947-2.,Its unique Visitrip indicator reduces intervention time by showing the faulty circuit.,Its Visisafe green strip guarantees the physical opening of the contacts to allow downstream maintenance.,Its fast closing mechanism independent of manual operation improves its service life.,This product is compliant with EN/IEC 60947-2 and EN/IEC 61009-2-1 standards.,Electrical endurance goes up to 10000 cycles, and mechanical endurance goes up to 20000 cycles.,The Ue operational voltage is 380VAC to 415VAC.,The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 4kV. The frequency is 50Hz.,It is DIN rail mountable. The width in 9mm pitches is 8.,The product color is white (RAL9003). The dimensions are (W) 72mm x (H) 86mm x (D) 78mm. The weight is 423g.,It has an IP20 degree of protection. It becomes IP40 once in modular enclosure according to IEC/EN 60529 standard.,The operating temperature is from -25°C to 40°C. The storage temperature is from -40°C to 70°C.

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Available on back order
4 - 6 W.Weeks
£108.20 Exc. VAT
£129.84 Inc. VAT

Main

Range Acti9
Product name Acti9 iC60 RCBO
product or component type Residual current breaker with overcurrent protection (RCBO)
Device short name iC60 RCBO
device application Distribution
Poles description 4P
Number of protected poles 4
[In] rated current 16 A
Network type AC
Trip unit technology Thermal-magnetic
Curve code C
Earth-leakage sensitivity 30 mA
Earth-leakage protection time delay Instantaneous
Earth-leakage protection class Type A
Breaking capacity 6000 A Icn at 380...415 V AC 50 Hz conforming to EN/IEC 61009-2-1,6 kA Icu at 380...415 V AC 50 Hz conforming to EN/IEC 60947-2
Suitability for isolation No conforming to IEC 60947-1
Quality labels VDE,NF,IMQ,KEMA-KEUR

Complementary

Complementary Outgoer
Network frequency 50 Hz
[Ue] rated operational voltage 380...415 V AC 50 Hz
Magnetic tripping limit 5...10 x In
Residual current tripping technology Voltage independent
[Ics] rated service breaking capacity 6000 A 100 % x Icn at 380...415 V AC 50 Hz conforming to EN/IEC 61009-2-1,6 kA 100 % x Icu at 380...415 V AC 50 Hz conforming to EN/IEC 60947-2
Rated breaking and making capacity Idm 6000 A at 380...415 V AC 50 Hz conforming to EN/IEC 61009-2-1
Limitation class 1 conforming to EN/IEC 61009-2-1
[Ui] rated insulation voltage 500 V AC 50 Hz
[Uimp] rated impulse withstand voltage 4 kV
Surge current 250 A
Contact position indicator No
Control type Toggle
Local signalling ON, OFF, fault trip
mounting mode Clip-on
mounting support DIN rail
Comb busbar and distribution block compatibility Top or bottom: YES,Bottom: biconnect
Connection pitch 9 mm between poles
9 mm pitches 8
Height 86 mm
Width 72 mm
Depth 78 mm
net weight 423 g
Colour White
Mechanical durability 20000 cycles
Electrical durability 10000 cycles
Connections - terminals Tunnel type terminal top or bottom 1…35 mm² rigid,Tunnel type terminal top or bottom 1…25 mm² flexible,Tunnel type terminal top or bottom 1…25 mm² flexible with ferrule
Wire stripping length 12 mm for top or bottom connection
Tightening torque 2 N.m
Earth-leakage protection Integrated

Environment

Standards EN/IEC 60947-2,EN/IEC 61009-2-1
IP degree of protection IP40 (distribution enclosure) conforming to IEC 60529,IP20 conforming to IEC 60529
Overvoltage category III conforming to IEC 60364
Electromagnetic compatibility 8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1
Tropicalisation 2
Relative humidity 95 % at 55 °C
Ambient air temperature for operation -25…60 °C
Ambient air temperature for storage -40…70 °C

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 8.700 cm
Package 1 Width 8.000 cm
Package 1 Length 10.000 cm
Package 1 Weight 434.000 g
Unit Type of Package 2 BB1
Number of Units in Package 2 3
Package 2 Height 9.800 cm
Package 2 Width 11.300 cm
Package 2 Length 24.800 cm
Package 2 Weight 1.383 kg
Unit Type of Package 3 S03
Number of Units in Package 3 18
Package 3 Height 30 cm
Package 3 Width 30 cm
Package 3 Length 40 cm
Package 3 Weight 8.800 kg

Contractual warranty

Warranty 18 months

Documentation

Product Datasheet

User guide

CAD

Environmental disclosure

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible