This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Schneider Electric

ABLP1A24100

ABLP1A24100 Schneider Electric

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for ABLP1A24100 Schneider Electric

ABLP1A24100 Schneider Electric - Regulated Power Supply, 100...240V AC, 24V 10A, single phase, Panel Mount

Extended Description for ABLP1A24100 Schneider Electric

ABLP1A24100 Schneider Electric - This Modicon ABLP regulated switch mode power supply (SMPS) supplies direct current voltage.,It has a rated input of 100V to 240V AC, a rated output current of 10A at 24V DC and a rated power of 240W.,It is ideal for supplying DC voltage necessary for automation equipment designed for applications in industrial, commercial and residential applications such as conveying, packaging, control, food & beverage, mining, oil & gas and water.,It provides a protection against overloads and short-circuits with automatic restart after the source of overload/short-circuit has been corrected,It has LED diagnostics indicator available in the front for troubleshooting instantly.,Its width is 190mm, its height is 50mm, its depth is 93mm. It weighs 0.850kg.,It is certified with CB-Scheme, cULus Listed, cURus recognized, RCM and EAC.,It is a power supply for commercial use, panel mount;,It is compatible with ABLPA02 mounting plate.,It installs on panel on side or on base with mounting plate fixing by screw.,ABLP power supplies bring energy to your automated systems. ABLP power supplies are designed for simple and repetitive machines, dedicated power supplies are particularly quality/price competitive due to their simplicity and compactness.,The main applications to use Modicon ABLP power supply are lifts, display panels, escalators, carwash, foodstuff ovens, etc.

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Available on back order
4 - 6 W.Weeks
£66.44 Exc. VAT
£79.73 Inc. VAT

Main

range of product Modicon Power Supply
product or component type Power supply
power supply type Regulated switch mode
Variant option Panel mount
Enclosure material Aluminium
Nominal input voltage 100...240 V AC single phase
Rated power in W 240 W
Output voltage 24 V DC
Power supply output current 10 A

Complementary

Input voltage limits 85...264 V AC
Nominal network frequency 50…60 Hz
Network system compatibility TN,TT,IT
Maximum leakage current 1 mA 240 V AC
Input protection type Integrated fuse (not interchangeable) 6.3 A
Inrush current 35 A at 115 V,60 A at 230 V
Power factor 0.95 at 115 V AC,0.91 at 230 V AC
Efficiency 87 % at 230 V AC
Output voltage adjustment 21.6...26.4 V
Power dissipation in W 36 W
Current consumption < 3.6 A 115 V AC,< 1.8 A 230 V AC
Turn-on time < 1.2 s
Holding time > 20 ms 115 V AC,> 40 ms 230 V AC
Startup with capacitive loads 8000 µF
Residual ripple < 150 mV
Meantime between failure [MTBF] 700000 h at 25 °C, full load conforming to SR 332
Output protection type Against overload and short-circuits, protection technology: automatic reset,Against over temperature, protection technology: manual reset,Against overvoltage, protection technology: manual reset
Connections - terminals Screw connection: 0.75...2.5 mm², (AWG 18...AWG 14) without wire end ferrule,Screw connection: 0.75...1.5 mm², (AWG 18...AWG 16) with wire end ferrule
Line and load regulation < 0.5 % at 0 to 100 % load at 25 °C,< 1 % at full voltage range in line at 25 °C
Status LED 1 LED (green) output voltage
Depth 190 mm
Height 50 mm
Width 93 mm
net weight 0.85 kg
Output coupling Parallel,Serial
Mounting support Top hat type TH35-15 rail conforming to IEC 60715,Top hat type TH35-7.5 rail conforming to IEC 60715,Double-profile DIN rail, panel mounting
Supply SELV conforming to IEC 60950-1,SELV conforming to IEC 60204-1,SELV conforming to IEC 60364-4-41
Dielectric strength 3000 V AC with input to output
Service life 10 year(s)
Overvoltage category II

Environment

Standards IEC 62368-1,EN/IEC 61010-1,EN 61010-2-201,EN/IEC 61204-3,IEC 61000-6-1,IEC 61000-6-2,IEC 61000-6-3,IEC 61000-6-4,IEC 61000-3-2,EN 61000-3-3,UL 62368-1,UL 61010-1,UL 61010-2-201,CSA C22.2 No 62368-1,CSA C22.2 No 61010-1,CSA C22.2 No 61010-2-201,IEC 60335-1,EN/IEC 62368-1
Product certifications CE,CULus,EAC,RCM,CB Scheme,KC
Operating altitude 5000 m
Shock resistance 150 m/s² for 11 ms
IP degree of protection IP10
Ambient air temperature for operation -10…50 °C without derating mounting position A, B, C, D, F, G < 2000 m,50…70 °C with current derating of 2.5 % per °C mounting position A, B, C, D, F, G < 2000 m,50…70 °C with current derating of 2.5 % per °C < 2000 m
Electrical shock protection class Class I
Pollution degree 2
Vibration resistance 3 mm (f= 2…9 Hz) conforming to IEC 60068-2-6,10 m/s² (f= 9…200 Hz) conforming to IEC 60068-2-6
Electromagnetic immunity Immunity to electrostatic discharge - test level: 8 kV (contact discharge) conforming to IEC 61000-4-2,Immunity to electrostatic discharge - test level: 15 kV (air discharge) conforming to IEC 61000-4-2,Immunity to conducted RF disturbances - test level: 15 V/m (80 MHz...2 GHz) conforming to IEC 61000-4-3,Immunity to conducted RF disturbances - test level: 5 V/m (2...2.7 GHz) conforming to IEC 61000-4-3,Immunity to conducted RF disturbances - test level: 5 V/m (2.7...6 GHz) conforming to IEC 61000-4-3,Immunity to fast transients - test level: 4 kV (on input-output) conforming to IEC 61000-4-4,Surge immunity test - test level: 4 kV (between power supply and earth) conforming to IEC 61000-4-5,Surge immunity test - test level: 3 kV (between phases) conforming to IEC 61000-4-5,Immunity to conducted RF disturbances - test level: 15 V (0.15...80 MHz) conforming to IEC 61000-4-6,Immunity to magnetic fields - test level: 30 A/m (50...60 Hz) conforming to IEC 61000-4-8,Immunity to voltage dips conforming to IEC 61000-4-11,Disturbing field emission conforming to EN 55016-2-3,Limits for harmonic current emissions conforming to IEC 61000-3-2, conforming to EN 55016-1-2, conforming to EN 55016-2-1
Electromagnetic emission Conducted emissions conforming to IEC 61000-6-3,Radiated emissions conforming to IEC 61000-6-4

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 6.000 cm
Package 1 Width 14.000 cm
Package 1 Length 24.500 cm
Package 1 Weight 984.000 g
Unit Type of Package 2 S03
Number of Units in Package 2 9
Package 2 Height 30.000 cm
Package 2 Width 30.000 cm
Package 2 Length 40.000 cm
Package 2 Weight 9.269 kg
Unit Type of Package 3 P06
Number of Units in Package 3 72
Package 3 Height 75.000 cm
Package 3 Width 80.000 cm
Package 3 Length 60.000 cm
Package 3 Weight 82.152 kg

Contractual warranty

Warranty 18 months

Documentation

Product Datasheet

Instruction sheet

Catalogue

CAD

Environmental disclosure

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image