This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Schneider Electric

ABLU3A48100

ABLU3A48100 Schneider Electric

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for ABLU3A48100 Schneider Electric

ABLU3A48100 Schneider Electric - Regulated Power Supply, 380...500V AC, 48V, 10A, 3 phases, Universal

Extended Description for ABLU3A48100 Schneider Electric

ABLU3A48100 Schneider Electric - This product is part of the Modicon ABL range, an offer of power supplies for industrial use.,It is a regulated switch mode power supply.,It has a rated input of 380V to 500V AC, a rated output current of 10A at 48V DC and a rated power output of 480W.,It supplies direct current voltage and ensures a protection against overloads and short-circuits with automatic or manual restart.,It operates from minus 25 to plus 55degrees celcius and plus 55 to 70degrees celcius with a current derating of 3.3%, at an altitude of less than 2000meters.,It measures 124mm high, 65mm wide, and 127.2mm deep. It weighs 1.15kg.,It is a power supply for industrial use.,It meets CE, CB Scheme, cULus Listed, UL HazLoc Class1Div2, cURus Recognized, RCM, EAC, UKCA, KC. To IEC/EN-UL/CSA 62368-1, IEC/EN-UL/CSA 61010-1/2 standards.,GV2ME07 or GV2RT06 circuit breakers are recommanded for its protection.,It installs on 35mm DIN rail.,It brings energy to your automated systems. Designed with extreme compactness for simple machines and applications.

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Available on back order
4 - 6 W.Weeks
£198.87 Exc. VAT
£238.64 Inc. VAT

Main

range of product Modicon Power Supply
product or component type Power supply
power supply type Regulated switch mode
Variant option Universal
Enclosure material Metal
Nominal input voltage 380...500 V AC three phase
Rated power in W 480 W
Output voltage 48 V DC
Power supply output current 10 A
Permissible temporary current boost 1.5 x In (for 5 seconds)

Complementary

Input voltage limits 320...575 V AC 3 phases
Nominal network frequency 50…60 Hz
Network system compatibility TN,TT,IT
Maximum leakage current 2 mA 500 V AC
Input protection type Integrated fuse (not interchangeable) 3.15 A,External protection (recommended)
Inrush current 35 A at 380 V,35 A at 500 V
Power factor 0.90 at 380 V AC,0.88 at 500 V AC
Efficiency 92 % at 380 V AC,92 % at 500 V AC
Output voltage adjustment 48…56 V
Power dissipation in W 33 W
Current consumption < 0.85 A 380 V AC,< 0.73 A 500 V AC
Turn-on time < 1 s
Holding time > 20 ms 380 V AC,> 20 ms 500 V AC
Startup with capacitive loads 200000 µF
Residual ripple < 150 mV
Meantime between failure [MTBF] 890200 h at 25 °C, full load conforming to SR 332,346200 h at 55 °C, 80 % load conforming to SR 332
Output protection type Against overload and short-circuits, protection technology: manual or automatic reset by switch,Against over temperature, protection technology: automatic reset,Against overvoltage, protection technology: manual reset
Connections - terminals Screw connection: 4...6 mm², (AWG 12...AWG 10) without wire end ferrule for output,Screw connection: 4 mm², (AWG 12) with wire end ferrule for output,Screw connection: 0.75…6 mm², (AWG 18...AWG 10) without wire end ferrule for input,Screw connection: 0.75...4 mm², (AWG 18...AWG 12) with wire end ferrule for input,Cage clamp: 0.2...1.5 mm², (AWG 22...AWG 16) without wire end ferrule for diagnostic relay,Cage clamp: 0.2...0.75 mm², (AWG 22...AWG 18) with wire end ferrule for diagnostic relay,Cage clamp: 0.2...0.75 mm², (AWG 22...AWG 18) with wire end ferrule for shut down input
Line and load regulation < 0.17 % at 100 % load in line at 25 °C,< 0.6 % +/- 0.5 % at 150 % load at 25 °C
Status LED 1 LED (green and red) product status
Depth 127.2 mm
Height 124 mm
Width 65 mm
net weight 1.15 kg
Output coupling Parallel
marking CE,UKCA
Mounting support Top hat type TH35-15 rail conforming to IEC 60715,Top hat type TH35-7.5 rail conforming to IEC 60715,Double-profile DIN rail
Supply SELV conforming to IEC 60950-1,SELV conforming to IEC 60204-1,SELV conforming to IEC 60364-4-41
Dielectric strength 4000 V AC with input to output,2000 V AC with input to ground,1500 V AC with output to ground,4000 V AC with input to diagnostic relay,500 V AC with output to diagnostic relay,1500 V AC with diagnostic relay to ground, with shutdown input not isolated from output
Diagnostic relay Electromechanical relay 1000.0 mA 30 V
Service life 10 year(s) 40 °C 80 % load
Overvoltage category III,II

Environment

Standards IEC 62368-1,EN/IEC 61204-3,IEC 61000-6-1,IEC 61000-6-2,IEC 61000-6-3,IEC 61000-6-4,IEC 61000-3-2,EN 61000-3-3,UL 62368-1,CSA C22.2 No 62368-1,CSA C22.2 No 107.1,EN/IEC 62368-1
Product certifications CE,CUL listed,CUL recognized,RCM,CB Scheme,EAC,KC,UKCA,CURus
Operating altitude < 5000 m overvoltage category III, overvoltage category II
Shock resistance 150 m/s² for 11 ms
IP degree of protection IP20
Ambient air temperature for operation -25…55 °C without current derating mounting position A < 2000 m,55…70 °C with current derating of 3.3 % per °C mounting position A < 2000 m
Electrical shock protection class Class I
Pollution degree 2
Vibration resistance 3.5 mm (f= 3…11.9 Hz) conforming to IEC 60068-2-6,20 m/s² (f= 11.9…150 Hz) conforming to IEC 60068-2-6
Electromagnetic immunity Immunity to electrostatic discharge - test level: 8 kV (contact discharge) conforming to IEC 61000-4-2,Immunity to electrostatic discharge - test level: 15 kV (air discharge) conforming to IEC 61000-4-2,Immunity to conducted RF disturbances - test level: 15 V/m (80 MHz...2 GHz) conforming to IEC 61000-4-3,Immunity to conducted RF disturbances - test level: 5 V/m (2...2.7 GHz) conforming to IEC 61000-4-3,Immunity to conducted RF disturbances - test level: 5 V/m (2.7...6 GHz) conforming to IEC 61000-4-3,Immunity to fast transients - test level: 4 kV (on input-output) conforming to IEC 61000-4-4,Surge immunity test - test level: 4 kV (between power supply and earth) conforming to IEC 61000-4-5,Surge immunity test - test level: 3 kV (between phases) conforming to IEC 61000-4-5,Immunity to conducted RF disturbances - test level: 15 V (0.15...80 MHz) conforming to IEC 61000-4-6,Immunity to magnetic fields - test level: 30 A/m (50...60 Hz) conforming to IEC 61000-4-8,Immunity to voltage dips conforming to IEC 61000-4-11,Disturbing field emission conforming to EN 55016-2-3,Limits for harmonic current emissions conforming to IEC 61000-3-2, conforming to EN 55016-1-2, conforming to EN 55016-2-1
Electromagnetic emission Conducted emissions conforming to IEC 61000-6-3,Radiated emissions conforming to IEC 61000-6-4

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 9.45 cm
Package 1 Width 17.7 cm
Package 1 Length 18.7 cm
Package 1 Weight 1.512 kg
Unit Type of Package 2 S03
Number of Units in Package 2 7
Package 2 Height 30.0 cm
Package 2 Width 30.0 cm
Package 2 Length 40.0 cm
Package 2 Weight 11.2 kg

Contractual warranty

Warranty 18 months

Documentation

Product Datasheet

Instruction sheet

Catalogue

CAD

Environmental disclosure

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible