Schneider Electric

ATS130N2D38LT

ATS130N2D38LT Schneider Electric

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for ATS130N2D38LT Schneider Electric

ATS130N2D38LT Schneider Electric - Altivar Soft Starter ATS130, 38A, 200 to 480V AC, control supply 24V DC

Extended Description for ATS130N2D38LT Schneider Electric

ATS130N2D38LT Schneider Electric - This soft starter belongs to the Altivar Soft Starter ATS130 range that is intended to start and stop asynchronous motors supplied from 200 to 480V.,With an operational rated current of 38A in normal duty, it supplies motor from 11 to 22kW according to mains voltage.,Compact, it provides mechanical and electrical flexibility in control panel design.,ATS130 is preventive maintenance free and allows optimized motor management especially in combination with TeSys Deca motor circuit breaker.,It is designed with Everlink power terminals and spring control terminals that avoid annual wire retightening.,This soft starter has the same width (55mm) as the TeSys Deca frame 3 motor circuit breaker; it allows the building of the ATS130 Soft Motor Starter.,Its dimensions are 55mm (width) x 165mm (depth) x 179mm (height), and it weighs 1.26kg.,Altivar Soft Starter ATS130 is designed to address pumps, fans, compressors, conveyors, and other simple machines.,It conforms to the IEC/EN60947-4-1 standard and has received the CE, EAC, UKCA, CCC, and RCM certifications.,It is possible to add a fixing kit to mount the TeSys Deca frame 3 motor circuit breaker on top of ATS130 or a cooling fan to extend the number of starts per hour.,The ATS130 soft starters can be mounted on a backplate or on a DIN rail, side by side, and they are compatible with a 200mm depth cabinet.,The Altivar Soft Starter ATS130 range is preventive maintenance-free and increases operational efficiency during design, manufacturing, and commissioning.,Ecolabel Green Premium compliant, this range is designed to take environmental considerations beyond current directives and regulations, compliant with RoHS and REACH.

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Available on back order
4 - 6 W.Weeks
£305.72 Exc. VAT
£366.86 Inc. VAT

Main

range of product Altivar Soft Starter ATS130
product or component type Soft starter
Product destination Asynchronous motors
Product specific application Simple machine
Device short name ATS130
Network number of phases 3 phases
Utilisation category AC-53A
Ue power supply voltage 200...480 V - 15...10 %
power supply frequency 50...60 Hz +/- 5 Hz
[Ie] rated operational current 38 A in line (at <40 °C)
Service factor at Ie 100
Torque control False
IP degree of protection IP20
Motor power kW 11 kW at 230 V normal duty,18.5 kW at 400 V normal duty,22 kW at 440 V normal duty
Motor power hp 10 hp at 200 V normal duty,10 hp at 208 V normal duty,10 hp at 230 V normal duty,25 hp at 460 V normal duty

Complementary

Overload current profile 300 % Ie for 5 s
On-load factor 70 %
Operating cycles/hour 50 cyc/h
Minimum motor current 20 % Ie
Device connection In line
[Us] control circuit voltage 24 V DC +/- 10 %
Control power 21.6 W starting and stopping,3 W steady state
Integrated motor overload protection False
Protection type Phase failure: mains,Thermal protection: starter,Bypass error: starter,Control voltage Us: starter
Rated current pwr loss specification 38.0 A
Power loss static current independent 3 W
Power loss per device current dependent 7 W
Power loss during starting 220 W 300 % Ie
Standards EN/IEC 60947-4-2,UL 60947-4-2,IEC 60664-1
Product certifications CE,UKCA,CCC,RCM,EAC
marking CE,CCC,UKCA,RCM,EAC
[Uc] control circuit voltage 24 V DC
Discrete input number 3
Discrete input type (DI) digital input, 10 kOhm, (DI2) digital input, 10 kOhm, (BOOST) digital input, 10 kOhm
Input compatibility Discrete input level 1 PLC conforming to EN/IEC 61131-2
Discrete input logic Digital input at State 0: 0...< 5 V and <= 0.2 mA at State 1: > 13 V, >= 0.5 mA
Relay output number 1
Relay output type Relay outputs R1A, R1C NO
Minimum switching current 2.5 mA at 24 V DC for relay outputs
Maximum switching current On resistive load for relay outputs : 1 A 250 V AC 400000 cycles,On resistive load for relay outputs : 1 A 30 V DC 400000 cycles,On inductive load for relay outputs : 1 A 250 V AC cos phi = 0.4 100000 cycles,On inductive load for relay outputs : 1 A 30 V DC cos phi = 0.4 100000 cycles
Discrete output number 1
Discrete output type Non programmable digital output DQ1 <= 30 V 200 mA
Display type 1 LED (green) for control power energized,1 LED (yellow and red) for motor operation phases, errors
Display screen available False
Operating position Vertical +/- 30 degree
Height 166 mm
Width 55 mm
Depth 165 mm
net weight 1.3 kg
Suitable for mounting onto standard rails True
Function available Deceleration voltage ramp,Boost
internal bypass True
material declaration True

Environment

Pollution degree Level 2
environmental class (during operation) Without salt mist: 3C3 conforming to IEC 60721-3-3,3S3 conforming to IEC 60721-3-3
[Uimp] rated impulse withstand voltage 4 kV
[Ui] rated insulation voltage 480 V
Electromagnetic compatibility Conducted and radiated emissions level B conforming to IEC 60947-4-2,Short voltage interruptions level 3 conforming to IEC 61000-4-11,Electrostatic discharge level 2 conforming to IEC 61000-4-2,Radiated radio-frequency electromagnetic field immunity test level 1 conforming to IEC 61000-4-3,Electrical fast transient/burst immunity test level 2 conforming to IEC 61000-4-4,Oscillatory waves immunity level 3 conforming to IEC 61000-4-12,Voltage/current impulse level 2 conforming to IEC 61000-4-5,Conducted disturbances, induced by radiofrequency fields level 1 conforming to IEC 61000-4-6
Ambient air temperature for operation -10…40 °C (without derating),40…60 °C (with current derating 1.5 % per °C)
Ambient air temperature for storage -25…70 °C
Ambient air transport temperature -40…70 °C
Operating altitude 0...1000 m without derating,1000...4000 m 1 % per 100 m
Relative humidity 5…95 % non condensing without dripping water conforming to IEC 60068-2-3
Maximum acceleration under vibrational stress (during operation) 10 m/s² at 9...200 Hz
Maximum acceleration under vibratory load (during storage) 10 m/s² at 9...200 Hz
Maximum acceleration under vibratory load (during transport) 10 m/s² at 9...200 Hz
Maximum deflection under vibratory load (during operation) 3 mm at 2-9 Hz
Maximum deflection under vibratory load (during storage) 3 mm at 2-9 Hz
Maximum deflection under vibratory load (during transport) 3 mm at 2-9 Hz
Maximum acceleration under shock impact (during operation) 100 m/s² at 11 ms
Maximum acceleration under shock load (during storage) 100 m/s² at 11 ms
Maximum acceleration under shock load (during transport) 100 m/s² at 11 ms

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 6.300 cm
Package 1 Width 27.000 cm
Package 1 Length 27.500 cm
Package 1 Weight 1.510 kg
Unit Type of Package 2 S06
Number of Units in Package 2 40
Package 2 Height 75.000 cm
Package 2 Width 60.000 cm
Package 2 Length 80.000 cm
Package 2 Weight 69.500 kg

Contractual warranty

Warranty 18 months

Documentation

Product Datasheet

User guide

Instruction sheet

Catalogue

CAD

Environmental disclosure