This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Schneider Electric

ATV212WD15N4C

ATV212WD15N4C Schneider Electric

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for ATV212WD15N4C Schneider Electric

ATV212WD15N4C Schneider Electric - variable speed drive ATV212 - 15kW - 20hp - 480V - 3ph - EMC class C1 - IP55

Extended Description for ATV212WD15N4C Schneider Electric

ATV212WD15N4C Schneider Electric - This Altivar 212 variable speed drive can feed 3-phase asynchronous motors.,Its protection index is IP55 and it has a built-in EMC filter.,It works at a rated power up to 15kW / 20hp and a rated voltage from 380V to 480V AC.,Its design is based on eco-energy with a reduction in energy consumption of up to 70% compared to a conventional control system.,Thanks to its cable temperature rise reduction technology, the Altivar 212 drive offers immediate, disturbance-free operation avoiding additional options such as a line choke or DC choke to deal with current harmonics.,It weighs 36.5kg and its dimensions are, 290mm wide, 560mm high, 315mm deep.,It is specifically designed for the most common fluid management applications in tertiary sector buildings (HVAC) like heating, ventilation, air conditioning and pumping.,It conforms to international standards IEC/EN 61800-5-1 and IEC/EN 61800-3 (immunity and conducted and radiated EMC emissions). It is also CE, UL, CSA, C-Tick and NOM certified.,The Altivar 212 offers optional motor chokes which can increase the maximum cable lengths between the drive and the motor and limit disturbance at the motor terminals.,It is designed to be mounted in vertical position (+/- 10 °) on a panel, thanks to 4 fixing holes.,The Altivar 212 drive can easily be adapted to all building management systems thanks to its numerous functions and communication protocols integrated as standard, Modbus, METASYS N2, APOGEE FLN P1 and BACnet.

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Available on back order
4 - 6 W.Weeks
£1,771.80 Exc. VAT
£2,126.15 Inc. VAT

Main

Device short name ATV212
Product destination Asynchronous motors
Network number of phases 3 phases
Motor power kW 15 kW
Motor power hp 20 hp
Supply voltage limits 323…528 V
Supply frequency 50...60 Hz - 5...5 %
Line current 22.8 A at 480 V,28.4 A at 380 V
range of product Altivar 212
product or component type Variable speed drive
Product specific application Pumps and fans in HVAC
communication port protocol BACnet,METASYS N2,LonWorks,APOGEE FLN,Modbus
[Us] rated supply voltage 380...480 V - 15...10 %
EMC filter Class C1 EMC filter integrated
IP degree of protection IP55

Complementary

Apparent power 23.2 kVA at 380 V
Continuous output current 30.5 A at 380 V,30.5 A at 460 V
Maximum transient current 33.6 A for 60 s
Speed drive output frequency 0.5…200 Hz
Speed range 1…10
Speed accuracy +/- 10 % of nominal slip 0.2 Tn to Tn
Local signalling 1 LED (red) for DC bus energized
Output voltage <= power supply voltage
Isolation Electrical between power and control
Type of cable Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 90 °C / XLPE/EPR,Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 70 °C / PVC,With UL Type 1 kit: 3 wire(s)UL 508 cable at 40 °C, copper 75 °C / PVC
Electrical connection VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES: terminal 2.5 mm² / AWG 14,L1/R, L2/S, L3/T: terminal 10 mm² / AWG 6,U/T1, V/T2, W/T3: terminal 16 mm² / AWG 4
Tightening torque 0.6 N.m (VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES),1.7 N.m, 15 lb.in (L1/R, L2/S, L3/T),3 N.m, 26.5 lb.in (U/T1, V/T2, W/T3)
Supply Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 A, protection type: overload and short-circuit protection,Internal supply: 24 V DC (21…27 V), <200 A, protection type: overload and short-circuit protection
Sampling duration 2 ms +/- 0.5 ms F discrete,2 ms +/- 0.5 ms R discrete,2 ms +/- 0.5 ms RES discrete,3.5 ms +/- 0.5 ms VIA analog,22 ms +/- 0.5 ms VIB analog
Response time FM 2 ms, tolerance +/- 0.5 ms for analog output(s),FLA, FLC 7 ms, tolerance +/- 0.5 ms for discrete output(s),FLB, FLC 7 ms, tolerance +/- 0.5 ms for discrete output(s),RY, RC 7 ms, tolerance +/- 0.5 ms for discrete output(s)
Accuracy +/- 0.6 % (VIA) for a temperature variation 60 °C,+/- 0.6 % (VIB) for a temperature variation 60 °C,+/- 1 % (FM) for a temperature variation 60 °C
Linearity error VIA: +/- 0.15 % of maximum value for input,VIB: +/- 0.15 % of maximum value for input,FM: +/- 0.2 % for output
Analogue output type FM switch-configurable voltage 0...10 V DC, impedance: 7620 Ohm, resolution 10 bits,FM switch-configurable current 0...20 mA, impedance: 970 Ohm, resolution 10 bits
Discrete output type Configurable relay logic: (FLA, FLC) NO - 100000 cycles,Configurable relay logic: (FLB, FLC) NC - 100000 cycles,Configurable relay logic: (RY, RC) NO - 100000 cycles
Minimum switching current 3 mA at 24 V DC for configurable relay logic
Maximum switching current 5 A at 250 V AC on resistive load - cos phi = 1 - L/R = 0 ms (FL, R),5 A at 30 V DC on resistive load - cos phi = 1 - L/R = 0 ms (FL, R),2 A at 250 V AC on inductive load - cos phi = 0.4 - L/R = 7 ms (FL, R),2 A at 30 V DC on inductive load - cos phi = 0.4 - L/R = 7 ms (FL, R)
Discrete input type F programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm,R programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm,RES programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm
Discrete input logic Positive logic (source) (F, R, RES), <= 5 V (state 0), >= 11 V (state 1),Negative logic (sink) (F, R, RES), >= 16 V (state 0), <= 10 V (state 1)
Dielectric strength 3535 V DC between earth and power terminals,5092 V DC between control and power terminals
Insulation resistance >= 1 mOhm 500 V DC for 1 minute
Frequency resolution Display unit: 0.1 Hz,Analog input: 0.024/50 Hz
Communication service Read holding registers (03) 2 words maximum,Monitoring inhibitable,Write single register (06),Time out setting from 0.1 to 100 s,Read device identification (43),Write multiple registers (16) 2 words maximum
Option card Communication card for LonWorks
Specific application HVAC
Discrete output number 2
Analogue input number 2
Analogue input type VIA switch-configurable voltage: 0...10 V DC 24 V max, impedance: 30000 Ohm, resolution 10 bits,VIB configurable voltage: 0...10 V DC 24 V max, impedance: 30000 Ohm, resolution 10 bits,VIB configurable PTC probe: 0...6 probes, impedance: 1500 Ohm,VIA switch-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 10 bits
Analogue output number 1
Physical interface 2-wire RS 485
Connector type 1 RJ45,1 open style
Transmission rate 9600 bps or 19200 bps
Transmission frame RTU
Number of addresses 1…247
Data format 8 bits, 1 stop, odd even or no configurable parity
Type of polarization No impedance
Asynchronous motor control profile Voltage/frequency ratio, 5 points,Voltage/frequency ratio - Energy Saving, quadratic U/f,Voltage/frequency ratio, 2 points,Flux vector control without sensor, standard,Voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo)
Torque accuracy +/- 15 %
Transient overtorque 120 % of nominal motor torque +/- 10 % for 60 s
Acceleration and deceleration ramps Linear adjustable separately from 0.01 to 3200 s,Automatic based on the load
Motor slip compensation Not available in voltage/frequency ratio motor control,Automatic whatever the load,Adjustable
Switching frequency 6...16 kHz adjustable,12...16 kHz with derating factor
Nominal switching frequency 12 kHz
Braking to standstill By DC injection
Network frequency 47.5...63 Hz
Prospective line Isc 22 kA
Protection type Overheating protection: drive,Thermal power stage: drive,Short-circuit between motor phases: drive,Input phase breaks: drive,Overcurrent between output phases and earth: drive,Overvoltages on the DC bus: drive,Break on the control circuit: drive,Against exceeding limit speed: drive,Line supply overvoltage and undervoltage: drive,Line supply undervoltage: drive,Against input phase loss: drive,Thermal protection: motor,Motor phase break: motor,With PTC probes: motor
Width 290 mm
Height 560 mm
Depth 315 mm
net weight 36.5 kg

Environment

Pollution degree 2 conforming to IEC 61800-5-1
IP degree of protection IP55 conforming to IEC 61800-5-1,IP55 conforming to IEC 60529
Vibration resistance 1.5 mm (f= 3…13 Hz) conforming to IEC 60068-2-6,1 gn (f= 13…200 Hz) conforming to EN/IEC 60068-2-8
Shock resistance 15 gn for 11 ms conforming to IEC 60068-2-27
Environmental characteristic Classes 3C1 conforming to IEC 60721-3-3,Classes 3S2 conforming to IEC 60721-3-3
Noise level 57.4 dB conforming to 86/188/EEC
Operating altitude 1000...3000 m limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m,<= 1000 m without derating
Relative humidity 5…95 % without condensation conforming to IEC 60068-2-3,5…95 % without dripping water conforming to IEC 60068-2-3
Ambient air temperature for operation -10…40 °C (without derating),40…50 °C (with derating factor)
Operating position Vertical +/- 10 degree
Product certifications NOM 117,C-Tick,CSA,UL
marking CE
Standards IEC 61800-3 category C1,IEC 61800-5-1,IEC 61800-3 environments 1 category C2,IEC 61800-3 environments 2 category C1,IEC 61800-3 environments 1 category C1,IEC 61800-3 environments 1 category C2,IEC 61800-3,IEC 61800-3 environments 2 category C2,IEC 61800-5-1,IEC 61800-3 environments 2 category C3,IEC 61800-3 environments 1 category C3,IEC 61800-3 environments 2 category C3,EN 55011 group 1 class B,IEC 61800-3 environments 2 category C1,EN 61800-3 category C1,IEC 61800-3,IEC 61800-3 environments 1 category C1,IEC 61800-3 environments 2 category C2,IEC 61800-3 environments 1 category C3
Assembly style With heat sink
Electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2,Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3,Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4,1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5,Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6,Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Regulation loop Adjustable PI regulator
Ambient air temperature for storage -25…70 °C

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 39.0 cm
Package 1 Width 40.0 cm
Package 1 Length 80.0 cm
Package 1 Weight 31.5 kg

Logistical informations

Country of origin US

Contractual warranty

Warranty 18 months

Documentation

Product Datasheet

User guide

Instruction sheet

Catalogue

CAD

Environmental disclosure

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible