This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Schneider Electric

ATV650C11N4F

ATV650C11N4F Schneider Electric

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for ATV650C11N4F Schneider Electric

ATV650C11N4F Schneider Electric - variable speed drive ATV650 - 110kW - 380...440V - IP54 - disconnect switch

Extended Description for ATV650C11N4F Schneider Electric

ATV650C11N4F Schneider Electric - This Altivar Process ATV600 variable speed drive can feed 3-phase synchronous and asynchronous power motors.,It features 3 built-in RJ45 communication ports as standard, 1 Ethernet port, 2 serial ports.,It works at a rated supply voltage from 380V to 440V AC.,This drive provides up to 30% energy saving when on standby due to the innovative ââStop and Goââoperation without additional costs.,It is suitable for motors with power rating up to 110kW for applications requiring slight overload (up to 120%).,It is suitable for motors with power rating up to 90kW for applications requiring significant overload (up to 150%).,It weighs 310kg and its dimensions are, 400mm wide, 2350mm high, 669mm deep.,This drive is focused on fluids management processing and energy saving, it offers extensive flexibility in water and wastewater, mining, minerals and metals, oil and gas and food and beverage applications.,Accessories (fan kit, graphic display terminal) and options (I/O expansion modules, communication modules, EMC input filters) are available with Altivar Process ATV600 drives, depending on the drive rating.,It is designed to be mounted in vertical position (+/- 10 °) on the floor.,This new concept of drives meets the major needs of process and utilities in terms of equipment efficiency and total cost of ownership by supporting the energy management, asset management and also the overall performance of the process.

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Available on back order
4 - 6 W.Weeks
£9,966.14 Exc. VAT
£11,959.37 Inc. VAT

Main

range of product Altivar Process ATV600
product or component type Variable speed drive
Product specific application Process and utilities
Device short name ATV650
Variant With disconnect switch
Product destination Asynchronous motors,Synchronous motors
EMC filter Integrated with 150 m conforming to IEC 61800-3 category C3
IP degree of protection IP00 conforming to IEC 60529,IP20 (with kit VW3A9705) conforming to IEC 61800-5-1,IP20 (with kit VW3A9705) conforming to IEC 60529,IP54 conforming to IEC 61800-5-1
[Us] rated supply voltage 380...440 V
Type of cooling Forced convection
Supply frequency 50...60 Hz - 5...5 %
[Us] rated supply voltage 380...440 V - 15...10 %
Motor power kW 110 kW (normal duty),90 kW (heavy duty)
Line current 179 A at 690 V (normal duty),151 A at 500 V (heavy duty),207 A at 690 V (heavy duty),174 A at 400 V (normal duty)
Prospective line Isc 50 kA
Apparent power 136 kVA at 440 V (normal duty),115 kVA at 440 V (heavy duty)
Continuous output current 211 A at 2.5 kHz for normal duty,173 A at 2.5 kHz for heavy duty
Asynchronous motor control profile Optimized torque mode,Variable torque standard,Optimized torque mode
Synchronous motor control profile Synchronous reluctance motor,Permanent magnet motor
Speed drive output frequency 0.1…500 Hz
Nominal switching frequency 2.5 kHz
Switching frequency 4...8 kHz with derating factor,2.5...8 kHz with derating factor
Safety function STO (safe torque off) SIL 3
Discrete input logic 16 preset speeds
communication port protocol Modbus serial,Ethernet,Modbus TCP
Option card Slot A: communication module, PROFINET,Slot A: communication module, DeviceNet,Slot A: communication module, Modbus TCP/EtherNet/IP,Slot A: communication module, CANopen daisy chain RJ45,Slot A: communication module, CANopen SUB-D 9,Slot A: communication module, CANopen screw terminals,Slot A/slot B: digital and analog I/O extension module,Slot A/slot B: output relay extension module,Slot A: communication module, Ethernet IP/Modbus TCP/MD-Link,Communication module, BACnet MS/TP,Communication module, Ethernet Powerlink,Slot A: communication module, Profibus DP V1

Complementary

mounting mode Floor-standing
Maximum transient current 232 A during 60 s (normal duty),260 A during 60 s (heavy duty)
Network number of phases 3 phases
Discrete output number 0
Discrete output type Relay outputs R1A, R1B, R1C 250 V AC 3000 mA,Relay outputs R1A, R1B, R1C 30 V DC 3000 mA,Relay outputs R2A, R2C 250 V AC 5000 mA,Relay outputs R2A, R2C 30 V DC 5000 mA,Relay outputs R3A, R3C 250 V AC 5000 mA,Relay outputs R3A, R3C 30 V DC 5000 mA
Output voltage <= power supply voltage
Permissible temporary current boost 1.5 x In during 60 s (heavy duty),1.1 x In during 60 s (normal duty)
Motor slip compensation Not available in permanent magnet motor law,Can be suppressed,Adjustable,Adjustable
Acceleration and deceleration ramps S, U or customized,Linear adjustable separately from 0.01...9999 s
Physical interface Ethernet,2-wire RS 485
Braking to standstill By DC injection
Protection type Safe torque off: motor,Motor phase break: motor,Thermal protection: drive,Safe torque off: drive,Overheating: drive,Overcurrent between output phases and earth: drive,Overload of output voltage: drive,Short-circuit protection: drive,Motor phase break: drive,Overvoltages on the DC bus: drive,Line supply overvoltage: drive,Line supply undervoltage: drive,Line supply phase loss: drive,Overspeed: drive,Break on the control circuit: drive,Thermal protection: motor
Transmission rate 10, 100 Mbits,4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
Frequency resolution Analog input: 0.012/50 Hz,Display unit: 0.1 Hz
Transmission frame RTU
Electrical connection Motor: screw terminal 4...10 mm²/AWG 12...AWG 8,Line side: screw terminal 4...10 mm²/AWG 12...AWG 8,Control: removable screw terminals 0.5...1.5 mm²
Connector type RJ45 (on the remote graphic terminal) for Modbus serial,RJ45 (on the remote graphic terminal) for Ethernet/Modbus TCP
Data format 8 bits, configurable odd, even or no parity
Type of polarization No impedance
Exchange mode Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP
Number of addresses 1…247 for Modbus serial
Method of access Slave Modbus TCP
Supply Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection,Internal supply for digital inputs and STO: 24 V DC (21…27 V), <200 mA, protection type: overload and short-circuit protection,External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection
Local signalling 3 LEDs (dual colour) for embedded communication status,4 LEDs (dual colour) for communication module status,1 LED (red) for presence of voltage,3 LEDs for local diagnostic
Width 400 mm
Height 2350 mm
Depth 669 mm
net weight 330 kg
Analogue input number 3
Analogue input type AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 31.5 kOhm, resolution 12 bits,AI1, AI2, AI3 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bits,AI2 voltage analog input: - 10...10 V DC, impedance: 31.5 kOhm, resolution 12 bits
Discrete input number 8
Discrete input type DI7, DI8 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
Input compatibility DI5, DI6: discrete input level 1 PLC conforming to IEC 65A-68,STOA, STOB: discrete input level 1 PLC conforming to IEC 61131-2,DI1...DI6: discrete input level 1 PLC conforming to IEC 61131-2
Discrete input logic Positive logic (source) (DI1...DI8), < 5 V (state 0), > 11 V (state 1),Negative logic (sink) (DI1...DI8), > 16 V (state 0), < 10 V (state 1)
Analogue output number 2
Analogue output type Software-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits,Software-configurable current AQ1, AQ2: 0...20 mA, resolution 10 bits,Software-configurable current DQ-, DQ+: 30 V DC,Software-configurable current DQ-, DQ+: 100 mA
Sampling duration 5 ms +/- 1 ms (DI5, DI6) - discrete input,5 ms +/- 0.1 ms (AI1, AI2, AI3) - analog input,10 ms +/- 1 ms (AO1) - analog output,2 ms +/- 0.5 ms (DI1...DI4) - discrete input
Accuracy +/- 1 % AO1, AO2 for a temperature variation 60 °C analog output,+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
Linearity error AO1, AO2: +/- 0.2 % for analog output,AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input
Relay output number 3
Relay output type Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles,Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles,Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles
Refresh time Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
Minimum switching current Relay output R1, R2, R3: 5 mA at 24 V DC
Maximum switching current Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC,Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC,Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC,Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC
Isolation Between power and control terminals
Maximum output frequency 500 kHz
Maximum input current 207.0 A
Variable speed drive application selection Building - HVAC compressor centrifugal
Motor power range AC-3 110…220 kW at 380…440 V 3 phases
Quantity per set 1
enclosure mounting Floor-standing

Environment

Insulation resistance > 1 MOhm 500 V DC for 1 minute to earth
Noise level 69 dB conforming to 86/188/EEC
Power dissipation in W Forced convection: 136 W at 500 V, switching frequency 4 kHz,2530 W, switching frequency 2.5 kHz (normal duty)
Volume of cooling air 720 m3/h
Operating position Vertical +/- 10 degree
Maximum THDI <48 % full load conforming to IEC 61000-3-12
Electromagnetic compatibility Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3,Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4,1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5,Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6,Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Pollution degree 2 conforming to IEC 61800-5-1
Vibration resistance 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6,1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6
Shock resistance 15 gn for 11 ms conforming to IEC 60068-2-27
Relative humidity 5…95 % without condensation conforming to IEC 60068-2-3
Ambient air temperature for operation 50…60 °C (with derating factor),-15…40 °C (without derating)
Ambient air temperature for storage -40…70 °C
Operating altitude 1000...4800 m with current derating 1 % per 100 m,<= 1000 m without derating
Product certifications ATEX,EAC,C-Tick
marking CE
Standards IEC 60204-1,IEC 61800-2,IEC 61800-3,IEC 61800-5-1
Overvoltage category III
Regulation loop Adjustable PID regulator
Noise level 69 dB
Pollution degree 3

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 214.5 cm
Package 1 Width 120.0 cm
Package 1 Length 110.5 cm
Package 1 Weight 370.0 kg

Contractual warranty

Warranty 18 months

Documentation

Product Datasheet

User guide

Instruction sheet

Catalogue

CAD

Environmental disclosure

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible