ATV650D55N4 Schneider Electric - variable speed drive ATV650 - 55kW/75HP - 380...480V - IP55

Extended Description for ATV650D55N4 Schneider Electric

ATV650D55N4 Schneider Electric - This Altivar Process ATV600 variable speed drive can feed 3-phase synchronous and asynchronous power motors.,It features 3 built-in RJ45 communication ports as standard, 1 Ethernet port, 2 serial ports.,It works at a rated supply voltage from 380V to 480V AC.,This drive provides up to 30% energy saving when on standby due to the innovative ââStop and Goââoperation without additional costs.,It is suitable for motors with power rating up to 55kW / 75hp for applications requiring slight overload (up to 120%).,It is suitable for motors with power rating up to 45kW / 60hp for applications requiring significant overload (up to 150%).,It weighs 87kg and its dimensions are, 345mm wide, 1250mm high, 375mm deep.,This drive is focused on fluids management processing and energy saving, it offers extensive flexibility in water and wastewater, mining, minerals and metals, oil and gas and food and beverage applications.,Accessories (fan kit, graphic display terminal) and options (I/O expansion modules, communication modules, EMC input filters) are available with Altivar Process ATV600 drives, depending on the drive rating.,It is designed to be mounted in vertical position (+/- 10 °) on a wall.,This new concept of drives meets the major needs of process and utilities in terms of equipment efficiency and total cost of ownership by supporting the energy management, asset management and also the overall performance of the process.

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Available on back order
4 - 6 W.Weeks
£4,352.58 Exc. VAT
£5,223.10 Inc. VAT

Main

range of product Altivar Process ATV600
product or component type Variable speed drive
Product specific application Process and utilities
Device short name ATV650
Variant Standard version
Product destination Asynchronous motors,Synchronous motors
EMC filter Integrated with 150 m conforming to IEC 61800-3 category C3
IP degree of protection IP55 conforming to IEC 60529,IP55 conforming to IEC 61800-5-1
[Us] rated supply voltage 380...480 V
Type of cooling Forced convection
Supply frequency 50...60 Hz - 5...5 %
[Us] rated supply voltage 380...480 V - 15...10 %
Motor power kW 45.0 kW (heavy duty),55.0 kW (normal duty)
Motor power hp 50 hp heavy duty,75 hp normal duty
Line current 69.1 A at 480 V (normal duty),67.1 A at 380 V (heavy duty),59 A at 480 V (heavy duty),97.2 A at 380 V (normal duty)
Prospective line Isc 50 kA
Apparent power 49.1 kVA at 480 V (heavy duty),70 kVA at 480 V (normal duty)
Continuous output current 72 A at 4 kHz for heavy duty,106 A at 2.5 kHz for normal duty
Asynchronous motor control profile Constant torque standard,Optimized torque mode,Optimized torque mode
Synchronous motor control profile Synchronous reluctance motor,Permanent magnet motor
Speed drive output frequency 0.1…500 Hz
Nominal switching frequency 2.5 kHz
Switching frequency 4...12 kHz with derating factor,2.5...8 kHz with derating factor
Safety function STO (safe torque off) SIL 3
Discrete input logic 16 preset speeds
communication port protocol Modbus TCP,Modbus serial,Modbus serial
Option card Slot A: communication module, PROFINET,Slot A: communication module, DeviceNet,Slot A: communication module, Modbus TCP/EtherNet/IP,Slot A: communication module, CANopen daisy chain RJ45,Slot A: communication module, CANopen SUB-D 9,Slot A: communication module, CANopen screw terminals,Slot A/slot B: digital and analog I/O extension module,Slot A/slot B: output relay extension module,Slot A: communication module, Ethernet IP/Modbus TCP/MD-Link,Communication module, BACnet MS/TP,Communication module, Ethernet Powerlink,Slot A: communication module, Profibus DP V1

Complementary

mounting mode Wall mount
Maximum transient current 111.8 A during 60 s (heavy duty),116.6 A during 60 s (normal duty)
Network number of phases 3 phases
Discrete output number 0
Discrete output type Relay outputs R1A, R1B, R1C 250 V AC 3000 mA,Relay outputs R1A, R1B, R1C 30 V DC 3000 mA,Relay outputs R2A, R2C 250 V AC 5000 mA,Relay outputs R2A, R2C 30 V DC 5000 mA,Relay outputs R3A, R3C 250 V AC 5000 mA,Relay outputs R3A, R3C 30 V DC 5000 mA
Output voltage <= power supply voltage
Permissible temporary current boost 1.5 x In during 60 s (heavy duty),1.1 x In during 60 s (normal duty)
Motor slip compensation Adjustable,Not available in permanent magnet motor law,Automatic whatever the load,Adjustable
Acceleration and deceleration ramps Linear adjustable separately from 0.01...9999 s
Physical interface Ethernet,2-wire RS 485
Braking to standstill By DC injection
Protection type Safe torque off: motor,Motor phase break: motor,Thermal protection: drive,Safe torque off: drive,Overheating: drive,Overcurrent between output phases and earth: drive,Overload of output voltage: drive,Short-circuit protection: drive,Motor phase break: drive,Overvoltages on the DC bus: drive,Line supply overvoltage: drive,Line supply undervoltage: drive,Line supply phase loss: drive,Overspeed: drive,Break on the control circuit: drive,Thermal protection: motor
Transmission rate 10, 100 Mbits,4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
Frequency resolution Analog input: 0.012/50 Hz,Display unit: 0.1 Hz
Transmission frame RTU
Electrical connection Line side: screw terminal 35...50 mm²/AWG 3...AWG 1,Motor: screw terminal 35...50 mm²/AWG 2...AWG 1,Control: removable screw terminals 0.5...1.5 mm²/AWG 20...AWG 16
Connector type RJ45 (on the remote graphic terminal) for Modbus serial,RJ45 (on the remote graphic terminal) for Ethernet/Modbus TCP
Data format 8 bits, configurable odd, even or no parity
Type of polarization No impedance
Exchange mode Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP
Number of addresses 1…247 for Modbus serial
Method of access Slave Modbus TCP
Supply Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection,Internal supply for digital inputs and STO: 24 V DC (21…27 V), <200 mA, protection type: overload and short-circuit protection,External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection
Local signalling 3 LEDs (dual colour) for embedded communication status,4 LEDs (dual colour) for communication module status,1 LED (red) for presence of voltage,3 LEDs for local diagnostic
Width 345 mm
Height 1250 mm
Depth 375 mm
net weight 87 kg
Analogue input number 3
Analogue input type AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 31.5 kOhm, resolution 12 bits,AI1, AI2, AI3 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bits,AI2 voltage analog input: - 10...10 V DC, impedance: 31.5 kOhm, resolution 12 bits
Discrete input number 8
Discrete input type DI7, DI8 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
Input compatibility DI5, DI6: discrete input level 1 PLC conforming to IEC 65A-68,STOA, STOB: discrete input level 1 PLC conforming to IEC 61131-2,DI1...DI6: discrete input level 1 PLC conforming to IEC 61131-2
Discrete input logic Positive logic (source) (DI1...DI8), < 5 V (state 0), > 11 V (state 1),Negative logic (sink) (DI1...DI8), > 16 V (state 0), < 10 V (state 1)
Analogue output number 2
Analogue output type Software-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits,Software-configurable current AQ1, AQ2: 0...20 mA, resolution 10 bits,Software-configurable current DQ-, DQ+: 30 V DC,Software-configurable current DQ-, DQ+: 100 mA
Sampling duration 5 ms +/- 1 ms (DI5, DI6) - discrete input,5 ms +/- 0.1 ms (AI1, AI2, AI3) - analog input,10 ms +/- 1 ms (AO1) - analog output,2 ms +/- 0.5 ms (DI1...DI4) - discrete input
Accuracy +/- 1 % AO1, AO2 for a temperature variation 60 °C analog output,+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
Linearity error AO1, AO2: +/- 0.2 % for analog output,AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input
Relay output number 3
Relay output type Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles,Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles,Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles
Refresh time Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
Minimum switching current Relay output R1, R2, R3: 5 mA at 24 V DC
Maximum switching current Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC,Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC,Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC,Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC
Isolation Between power and control terminals
Maximum output frequency 500 kHz
Maximum input current 97.2 A
Variable speed drive application selection Building - HVAC compressor centrifugal
Motor power range AC-3 55…100 kW at 380…440 V 3 phases
Quantity per set 1
enclosure mounting Wall mounted

Environment

Insulation resistance > 1 MOhm 500 V DC for 1 minute to earth
Noise level 69.9 dB conforming to 86/188/EEC
Operating position Vertical +/- 10 degree
Maximum THDI <48 % from 80...100 % of load conforming to IEC 61000-3-12
Electromagnetic compatibility Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3,Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4,1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5,Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6,Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Pollution degree 2 conforming to IEC 61800-5-1
Vibration resistance 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6,1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6
Shock resistance 15 gn for 11 ms conforming to IEC 60068-2-27
Relative humidity 5…95 % without condensation conforming to IEC 60068-2-3
Ambient air temperature for operation 40…50 °C (with derating factor),-15…40 °C (without derating)
Ambient air temperature for storage -40…70 °C
Operating altitude 1000...4800 m with current derating 1 % per 100 m,<= 1000 m without derating
Product certifications UL,CSA,DNV-GL,ABS,Bureau Veritas,TÜV,ATEX INERIS
marking CE
Standards IEC 61800-3,IEC 61800-3 environment 1 category C2,EN/IEC 61800-3 environment 2 category C3,IEC 61800-5-1,IEC 61000-3-12,IEC 60721-3,IEC 61508,IEC 13849-1,UL 508C
Overvoltage category III
Regulation loop Adjustable PID regulator
Noise level 69.9 dB
Pollution degree 3

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 68.000 cm
Package 1 Width 143.000 cm
Package 1 Length 48.000 cm
Package 1 Weight 79.000 kg

Contractual warranty

Warranty 18 months

Documentation

Product Datasheet

User guide

Instruction sheet

Catalogue

CAD

Environmental disclosure

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible