Schneider Electric

ATV660C50Q4X1

ATV660C50Q4X1 Schneider Electric

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for ATV660C50Q4X1 Schneider Electric

ATV660C50Q4X1 Schneider Electric - Variable speed drive, Altivar Process ATV600, Compact System ATV660, 500/400 kW, 400 V, IP23

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Available on back order
4 - 6 W.Weeks
£24,727.25 Exc. VAT
£29,672.70 Inc. VAT

Main

range of product Altivar Process ATV600
product or component type Variable speed drive
Product specific application Process and utilities
Device short name ATV660
Product destination Synchronous motors,Asynchronous motors
Assembly style In floor-standing enclosure compact version
Provided equipment Enclosure Spacial SF,Graphical operating panel in the enclosure door,Frequency inverter,Main switch,Line choke,Terminal block main supply,Terminal block motor
Cable entry Bottom
Colour of enclosure Light grey (RAL 7035)
IP degree of protection IP23 conforming to IEC 61800-5-1
Type of cooling Forced convection
[Us] rated supply voltage 380...415 V - 10...6 %
Supply frequency 50/60 Hz +/-5 %
Network number of phases 3 phases
Overvoltage category III
Asynchronous motor control profile Variable torque standard,Constant torque standard,Optimized torque mode
Synchronous motor control profile Permanent magnet motor
Output voltage <= power supply voltage
Permissible temporary current boost 1.1 x In during 60 s (normal duty),1.5 x In during 60 s (heavy duty)
Nominal switching frequency 2.5 kHz
Switching frequency 2...8 kHz adjustable with derating factor
Speed drive output frequency 0.1…500 Hz
Motor power kW 500 kW for normal duty,400 kW for heavy duty
Continuous output current 900 A at 2.5 kHz for normal duty,730 A at 2.5 kHz for heavy duty
Maximum transient current 990 A during 60 s per 10 min (normal duty),1095 A during 60 s per 10 min (heavy duty)
Line current 846 A at 400 V (normal duty),681 A at 400 V (heavy duty)
Apparent power 586 kVA at 400 V (normal duty),472 kVA at 400 V (heavy duty)
Maximum THDI <39 % full load conforming to IEC 61000-3-12
Short-circuit protection Internal: 400.0 A 3 aR fuse,Upstream: 1000.0 A gG fuse (normal duty),Upstream: 800.0 A gG fuse (heavy duty)
Energy efficiency ratio 0.98
Power dissipation in W 13330 W, total (normal duty),9800 W, total (heavy duty),1530 W, control part (normal duty),1020 W, control part (heavy duty)
Volume of cooling air 1740 m3/h for power,280 m3/h for control
Noise level 71 dB conforming to 86/188/EEC - physical agents (noise) directive
Prospective line Isc 50 kA for 100 ms
Electrical connection Removable screw terminals, clamping capacity: 0.5...1.5 mm² for control,M12 bar for main supply,M12 bar for motor
Motor recommanded cable cross section 5 x (3 x 120 mm²) (normal duty),4 x (3 x 185 mm²) (normal duty),3 x (3 x 185 mm²) (heavy duty),4 x (3 x 120 mm²) (heavy duty)
Width 800 mm
Height 2150 mm
Depth 664 mm
net weight 650 kg
number of preset speeds 16 preset speeds
communication port protocol Modbus TCP,EtherNet/IP,Modbus serial
Option card Slot A: communication module, Profibus DP V1,Slot A: communication module, PROFINET,Slot A: communication module, DeviceNet,Slot A: communication module, Modbus TCP/EtherNet/IP,Slot A: communication module, CANopen daisy chain RJ45,Slot A: communication module, CANopen SUB-D 9,Slot A: communication module, CANopen screw terminals,Slot A/slot B: digital and analog I/O extension module,Slot A/slot B: output relay extension module
Safety function STO (safe torque off), level SIL 3 for <= 100 ms
EMC filter Integrated conforming to EN/IEC 61800-3, category C3, shielded cable with 150 m,Integrated conforming to EN/IEC 61800-3, category C4, unshielded cable with 250 m

Complementary

Motor slip compensation Can be suppressed,Not available in permanent magnet motor law,Adjustable,Automatic whatever the load
Acceleration and deceleration ramps S, U or customized,Linear adjustable separately from 0.01 to 9000 s
Braking to standstill By DC injection
Protection type Motor: thermal protection,Motor: safe torque off,Motor: motor phase break,Drive: thermal protection,Drive: safe torque off,Drive: overheating,Drive: overcurrent (between output phases and earth),Drive: overload (output),Drive: short-circuit protection,Drive: motor phase break,Drive: overvoltage (DC bus),Drive: line supply overvoltage,Drive: line supply undervoltage,Drive: line supply phase loss,Drive: overspeed,Drive: break on the control circuit,Drive: short-circuit protection with semi-conductor fuse (main supply),Drive: fan monitoring
Frequency resolution Display unit: 0.1 Hz,Analog input: 0.012/50 Hz
Connector type RJ45 (on the control block) for Modbus serial,RJ45 (on the control block) for Ethernet IP/Modbus TCP
Physical interface 2-wire RS 485 for Modbus serial
Transmission frame RTU for Modbus serial
Transmission rate 10/100 Mbit/s for Ethernet IP/Modbus TCP,4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
Exchange mode Half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
Data format 8 bits, configurable odd, even or no parity for Modbus serial
Type of polarization No impedance for Modbus serial
Number of addresses 1…247 for Modbus serial
Method of access Slave Modbus TCP
Supply External supply for digital inputs: 24 V DC (10…30 V), <1.25 mA, protection type: overload and short-circuit protection,Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection,Internal supply for digital inputs and STO: 24 V DC (21…27 V), <200 mA, protection type: overload and short-circuit protection
Local signalling LCD display unit front door operation function, status and configuration
Analogue input number 3
Analogue input type AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution 12 bits,AI1, AI2, AI3 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bits
Discrete input number 8
Discrete input type DI1...DI6 programmable, 24 V DC (<= 30 V), impedance: 3.5 kOhm,DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V),STOA, STOB safe torque off, 24 V DC (<= 30 V), impedance: > 2.2 kOhm
Input compatibility DI1...DI6: discrete input level 1 PLC conforming to EN/IEC 61131-2,DI5, DI6: discrete input level 1 PLC conforming to IEC 65A-68,STOA, STOB: discrete input level 1 PLC conforming to EN/IEC 61131-2
Discrete input logic Positive logic (source) (DI1...DI6), < 5 V (state 0), > 11 V (state 1),Negative logic (sink) (DI1...DI6), > 16 V (state 0), < 10 V (state 1),Positive logic (source) (DI5, DI6), < 0.6 V (state 0), > 2.5 V (state 1),Positive logic (source) (STOA, STOB), < 5 V (state 0), > 11 V (state 1)
Analogue output number 2
Analogue output type Software-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits,Software-configurable current AQ1, AQ2: 0...20 mA, resolution 10 bits
Sampling duration 2 ms +/- 0.5 ms (DI1...DI4) - discrete input,5 ms +/- 1 ms (DI5, DI6) - discrete input,5 ms +/- 1 ms (AI1, AI2, AI3) - analog input,10 ms +/- 1 ms (AQ1, AQ2) - analog output
Accuracy +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input,+/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
Linearity error AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input,AQ1, AQ2: +/- 0.2 % for analog output
Relay output number 3
Relay output type Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles,Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles,Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
Refresh time Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
Minimum switching current Relay output R1, R2, R3: 5 mA at 24 V DC
Maximum switching current Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC,Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC,Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC,Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
Isolation Between power and control terminals

Environment

Insulation resistance > 1 MOhm 500 V DC for 1 minute to earth
Operating position Vertical +/- 10 degree
Electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2,Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3,Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4,1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5,Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Pollution degree 2 conforming to EN/IEC 61800-5-1
Vibration resistance 1.5 mm peak to peak (f= 3…10 Hz) conforming to IEC 60068-2-6,0.6 gn (f= 10…200 Hz) conforming to IEC 60068-2-6,3M3 conforming to IEC 60721-3-3
Shock resistance 4 gn for 11 ms conforming to IEC 60068-2-27,3M2 conforming to IEC 60721-3-3
Relative humidity 5…95 % without condensation conforming to IEC 60068-2-3
Ambient air temperature for operation -10…0 °C without derating (with option enclosure heating),0…40 °C without derating,40…50 °C with derating factor
Ambient air temperature for storage -25…70 °C
Operating altitude < 1000 m without derating,1000...2000 m with current derating 1 % per 100 m,2000...3800 m with current derating 1 % per 100 m for TT earthing system,2000...3800 m with current derating 1 % per 100 m for TN earthing system,2000...3800 m with current derating 1 % per 100 m for IT earthing system,3800...4800 m with current derating 1 % per 100 m for TT earthing system,3800...4800 m with current derating 1 % per 100 m for TN earthing system
Environmental characteristic Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3,Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3,Humidity resistant class 3K3 conforming to EN/IEC 60721-3-3
Standards EN/IEC 60204-1,EN/IEC 61800-2,EN/IEC 61800-3,EN/IEC 61800-5-1
Product certifications ATEX,EAC,C-Tick
marking CE

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 215 cm
Package 1 Width 66.9 cm
Package 1 Length 80 cm
Package 1 Weight 700 kg
Unit Type of Package 2 CAR
Number of Units in Package 2 1
Package 2 Height 230 cm
Package 2 Width 80 cm
Package 2 Length 95 cm
Package 2 Weight 670 kg

Contractual warranty

Warranty 18 months

Documentation

Product Datasheet

User guide

Catalogue

CAD

Environmental disclosure

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible