Description for ATV71HD30Y Schneider Electric

ATV71HD30Y Schneider Electric - variable speed drive ATV71 - 30kW - 690V - EMC filter-graphic terminal

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Available on back order
4 - 6 W.Weeks
£19,996.47 Exc. VAT
£23,995.77 Inc. VAT

Main

range of product Altivar 71
product or component type Variable speed drive
Product specific application Complex, high-power machines
Component name ATV71
Motor power kW 22 kW, 3 phases at 500 V,30 kW, 3 phases at 690 V
Motor power hp 30 hp, 3 phases at 575 V
Maximum motor cable length 10 m shielded cable,10 m unshielded cable
power supply voltage 500...690 V - 15...10 %
Network number of phases 3 phases
Line current 28 A for 600 V 3 phases / 30 hp,33 A for 500 V 3 phases 22 kW,34 A for 690 V 3 phases 30 kW
EMC filter Integrated
Assembly style With heat sink
Variant Reinforced version
Prospective line Isc 22 kA for 3 phases
Nominal output current 32 A at 4 kHz 575 V 3 phases / 30 hp,35 A at 4 kHz 500 V 3 phases 22 kW,35 A at 4 kHz 690 V 3 phases 30 kW
Maximum transient current 52.5 A for 60 s 3 phases 22 kW,57.75 A for 2 s 3 phases / 30 hp,57.75 A for 2 s 3 phases 30 kW
Output frequency 0.1…500 Hz
Nominal switching frequency 4 kHz
Switching frequency 2.5...6 kHz adjustable,4...6 kHz with derating factor
Asynchronous motor control profile Flux vector control (FVC) with sensor (current vector),ENA (Energy adaptation) system for unbalanced loads,Sensorless flux vector control (SFVC) (voltage or current vector),Voltage/frequency ratio (2 or 5 points)
Type of polarization No impedance for Modbus

Complementary

Product destination Synchronous motors,Asynchronous motors
power supply voltage limits 425…759 V
power supply frequency 50...60 Hz - 5...5 %
power supply frequency limits 47.5...63 Hz
Speed range 1…100 for asynchronous motor in open-loop mode, without speed feedback,1…1000 for asynchronous motor in closed-loop mode with encoder feedback,1…50 for synchronous motor in open-loop mode, without speed feedback
Speed accuracy +/- 0.01 % of nominal speed in closed-loop mode with encoder feedback 0.2 Tn to Tn,+/- 10 % of nominal slip without speed feedback 0.2 Tn to Tn
Torque accuracy +/- 15 % in open-loop mode, without speed feedback,+/- 5 % in closed-loop mode with encoder feedback
Transient overtorque 170 % of nominal motor torque +/- 10 % for 60 s every 10 minutes,220 % of nominal motor torque +/- 10 % for 2 s
Braking torque <= 150 % with braking or hoist resistor,30 % without braking resistor
Synchronous motor control profile Vector control without speed feedback
Regulation loop Adjustable PI regulator
Motor slip compensation Suppressable,Automatic whatever the load,Not available in voltage/frequency ratio (2 or 5 points),Adjustable
diagnostic 1 LED (red) for drive voltage
Output voltage <= power supply voltage
Insulation Electrical between power and control
type of cable for mounting in an enclosure With a NEMA Type1 kit: 3 wire(s)UL 508 cable at 40 °C, copper 75 °C / PVC,With an IP21 or an IP31 kit: 3 wire(s)IEC cable at 40 °C, copper 70 °C / PVC,Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 70 °C / PVC,Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 90 °C / XLPE/EPR
Electrical connection Terminal, clamping capacity: 2.5 mm², AWG 14 (AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR),Terminal, clamping capacity: 50 mm², AWG 1/0 (L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB)
Tightening torque 0.6 N.m (AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR),12 N.m, 102.2 lb.in (L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB)
Supply Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection,Internal supply: 24 V DC (21…27 V), <200 mA, protection type: overload and short-circuit protection
Analogue input number 2
Analogue input type AI1-/Al1+ bipolar differential voltage: +/- 10 V DC 24 V max, resolution 11 bits + sign,AI2 software-configurable current: 0...20 mA, impedance: 242 Ohm, resolution 11 bits,AI2 software-configurable voltage: 0...10 V DC 24 V max, impedance: 30000 Ohm, resolution 11 bits
input sampling time 2 ms +/- 0.5 ms (AI1-/Al1+) - analog input(s),2 ms +/- 0.5 ms (Al2) - analog input(s),2 ms +/- 0.5 ms (LI1...LI5) - discrete input(s),2 ms +/- 0.5 ms (LI6)if configured as logic input - discrete input(s)
Response time <= 100 ms in STO (Safe Torque Off),AO1 2 ms, tolerance +/- 0.5 ms for analog output(s),R1A, R1B, R1C 7 ms, tolerance +/- 0.5 ms for discrete output(s),R2A, R2B 7 ms, tolerance +/- 0.5 ms for discrete output(s)
absolute accuracy precision +/- 0.6 % (AI1-/Al1+) for a temperature variation 60 °C,+/- 0.6 % (AI2) for a temperature variation 60 °C,+/- 1 % (AO1) for a temperature variation 60 °C
Linearity error +/- 0.15 % of maximum value (AI1-/Al1+, AI2),+/- 0.2 % (AO1)
Analogue output number 1
Analogue output type AO1 software-configurable logic output 10 V 20 mA,AO1 software-configurable current 0...20 mA, impedance: 500 Ohm, resolution 10 bits,AO1 software-configurable voltage 0...10 V DC, impedance: 470 Ohm, resolution 10 bits
Discrete output number 2
Discrete output type Configurable relay logic: (R1A, R1B, R1C) NO/NC - 100000 cycles,Configurable relay logic: (R2A, R2B) NO - 100000 cycles
Minimum switching current 3 mA at 24 V DC for configurable relay logic
Maximum switching current R1, R2: 2 A at 250 V AC inductive load, cos phi = 0.4,R1, R2: 2 A at 30 V DC inductive load, cos phi = 0.4,R1, R2: 5 A at 250 V AC resistive load, cos phi = 1,R1, R2: 5 A at 30 V DC resistive load, cos phi = 1
Discrete input number 7
Discrete input type LI1...LI5: programmable 24 V DC with level 1 PLC, impedance: 3500 Ohm,LI6: switch-configurable 24 V DC with level 1 PLC, impedance: 3500 Ohm,LI6: switch-configurable PTC probe 0…6, impedance: 1500 Ohm,PWR: safety input 24 V DC, impedance: 1500 Ohm conforming to ISO 13849-1 level d
Discrete input logic Negative logic (sink) (LI1...LI5), > 16 V (state 0), < 10 V (state 1),Positive logic (source) (LI1...LI5), < 5 V (state 0), > 11 V (state 1),Negative logic (sink) (LI6)if configured as logic input, > 16 V (state 0), < 10 V (state 1),Positive logic (source) (LI6)if configured as logic input, < 5 V (state 0), > 11 V (state 1)
Acceleration and deceleration ramps Linear adjustable separately from 0.01 to 9000 s,S, U or customized,Automatic adaptation of ramp if braking capacity exceeded, by using resistor
Braking to standstill By DC injection
Protection type Against exceeding limit speed: drive,Against input phase loss: drive,Break on the control circuit: drive,Input phase breaks: drive,Line supply overvoltage: drive,Line supply undervoltage: drive,Overcurrent between output phases and earth: drive,Overheating protection: drive,Overvoltages on the DC bus: drive,Short-circuit between motor phases: drive,Thermal protection: drive,Motor phase break: motor,Power removal: motor,Thermal protection: motor
Insulation resistance > 1 mOhm 500 V DC for 1 minute to earth
Frequency resolution Analog input: 0.024/50 Hz,Display unit: 0.1 Hz
communication port protocol Modbus,CANopen
Connector type 1 RJ45 (on front face) for Modbus,1 RJ45 (on terminal) for Modbus,Male SUB-D 9 on RJ45 for CANopen
Physical interface 2-wire RS 485 for Modbus
Transmission frame RTU for Modbus
Transmission rate 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps for Modbus on terminal,9600 bps, 19200 bps for Modbus on front face,20 kbps, 50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps for CANopen
Data format 8 bits, 1 stop, even parity for Modbus on front face,8 bits, odd even or no configurable parity for Modbus on terminal
Number of addresses 1…127 for CANopen,1…247 for Modbus
Method of access Slave CANopen
marking CE
Operating position Vertical +/- 10 degree
Height 420 mm
Depth 236 mm
Width 240 mm
net weight 30 kg
Option card Communication card for CC-Link,Controller inside programmable card,Communication card for DeviceNet,Communication card for EtherNet/IP,Communication card for Fipio,I/O extension card,Communication card for Interbus-S,Interface card for encoder,Communication card for Modbus Plus,Communication card for Modbus TCP,Communication card for Modbus/Uni-Telway,Overhead crane card,Communication card for Profibus DP,Communication card for Profibus DP V1

Environment

Noise level 59.9 dB conforming to 86/188/EEC
Dielectric strength 3110 V DC between earth and power terminals,5345 V DC between control and power terminals
Electromagnetic compatibility 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5,Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6,Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4,Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2,Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3,Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Standards EN/IEC 61800-3,EN/IEC 61800-5-1,EN 61800-3 environments 2 category C3,EN 61800-3 environments 1 category C3,UL Type 1,EN 55011 class A group 2,IEC 60721-3-3 class 3C2
Product certifications GOST,UL,CSA,C-Tick,NOM 117
Pollution degree 2 conforming to EN/IEC 61800-5-1,3 conforming to UL 840
IP degree of protection IP20 on upper part without blanking plate on cover conforming to EN/IEC 60529,IP20 on upper part without blanking plate on cover conforming to EN/IEC 61800-5-1,IP21 conforming to EN/IEC 60529,IP21 conforming to EN/IEC 61800-5-1,IP41 on upper part conforming to EN/IEC 60529,IP41 on upper part conforming to EN/IEC 61800-5-1,IP54 on lower part conforming to EN/IEC 60529,IP54 on lower part conforming to EN/IEC 61800-5-1
Vibration resistance 1 gn (f= 13…200 Hz) conforming to EN/IEC 60068-2-6,1.5 mm peak to peak (f= 3…13 Hz) conforming to EN/IEC 60068-2-6
Shock resistance 15 gn for 11 ms conforming to EN/IEC 60068-2-27
Relative humidity 5…95 % without condensation conforming to IEC 60068-2-3,5…95 % without dripping water conforming to IEC 60068-2-3
Ambient air temperature for operation -10…50 °C (without derating)
Ambient air temperature for storage -25…70 °C
Operating altitude <= 1000 m without derating,1000...2260 m with current derating 1 % per 100 m

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 37.5 cm
Package 1 Width 40.0 cm
Package 1 Length 60.0 cm
Package 1 Weight 31.75 kg
Unit Type of Package 2 P06
Number of Units in Package 2 2
Package 2 Height 77.0 cm
Package 2 Width 60.0 cm
Package 2 Length 80.0 cm
Package 2 Weight 72.0 kg

Contractual warranty

Warranty 18 months