This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Schneider Electric

IMD-IM20-H

IMD-IM20-H Schneider Electric

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for IMD-IM20-H Schneider Electric

IMD-IM20-H Schneider Electric - VIGILOHM IM20 - H 110-230 V CA

Extended Description for IMD-IM20-H Schneider Electric

IMD-IM20-H Schneider Electric - This device belongs to the Vigilohm range designed to monitor ungrounded/IT electrical networks, in accordance to installation and products standards.,According to IEC standards, it is mandatory to equip IT medical premises with Insulation Monitoring Devices (IMD).,This device is dedicated to monitoring AC, DC and ACDC medical IT systems.,It mesures the system insulation resistance by injecting a low frequency AC current between the network and ground.,Configuration will be set in accordance to medical standards, from the front of the device, through the HMI screen.,Setting are related to insulation alarm thresholds from 50 kilohms to 500 kilohms, and Transformer overheat and overload alarms.,It monitors networks up to 230VAC, 230VDC, in medical IT architecture, and well as the medical IT transformer.,The black and white screen can displays insulation resistance from 100 ohms to 10 megohms.,Auto-test starts automatically every 5 hours, and on demand.,In case the system insulation resistance drops below the set threshold, meaning a ground fault occurred, an alarm is triggered thru the IMD output relay within 4 seconds.,Once no fault is monitored, the alarm is cleared, the alarm relay is back to normal.,The device can be supplied by a 110VAC to 230VAC source or a 125VDC to 250VDC, all with a tolérence of plus or minus 15%.,This product can be installed on DIN rail, or flush mounted.,Front face ingress protection is IP52, rear IP20 and overvolage category III.,The monitoring device is equipped with a RS485 communication port, Modbus protocol.

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Available on back order
4 - 6 W.Weeks
£446.02 Exc. VAT
£535.22 Inc. VAT

Main

Range Vigilohm
Device short name IM20-H
product or component type Insulation monitoring device
device application Hospital
Earthing system IT
User language Russian,Spanish,French,Chinese,German,Portuguese,English,Italian

Complementary

Network rated voltage 0…230 V - AC at 50/60 Hz (phase to neutral) ,0…100 V - DC
Data recording Alarm logs
Type of measurement Network insulation resistance - measurement range: 1 kOhm...10 MOhm,History of alarms
Local signalling Green indicator light: satisfactory insulation resistance,Orange indicator light: below fault threshold
Threshold setting Fault: 50...500 kOhm
Response time <= 1 s
auxiliary supply voltage 125...250 V DC +/- 15 %,110...230 V AC 50/60 Hz +/- 15 %
Power consumption in VA 12 VA
Measurement voltage 25 V
Measurement current 0…0.2 mA
internal impedance 110 kOhm - AC at 50/60 Hz
Test function Manual
output contact 1 C/O standard or fail-safe
breaking capacity 250 V - AC at 6 A,12...24 V - DC at 6 A
Input function Injection inhibition: 24 V DC 5 mA
communication port protocol Modbus
Communication port support RS485
Display type Digital display
mounting mode Clip-on,Flush-mounted
mounting support DIN rail,Panel
Connections - terminals Removable screw terminal block0.2…2.5 mm²
Material Thermoplastic
net weight 0.25 kg
Height 110 mm
Width 96 mm
Depth 59 mm

Environment

Dielectric strength 4000 V - AC,5500 V - DC
IP degree of protection Front face: IP52
Environmental characteristic Exposure to damp heat not in service conforming to IEC 60068-2-30,Exposure to damp heat in service conforming to IEC 60068-2-56,Salt mist conforming to IEC 60068-2-52
Pollution degree 2
Type of installation Indoor
Standards IEC 61010-1,IEC 61557-8,IEC 60364-7-710,IEC 61326-2-4
Product certifications DNV,EAC,BV,CE
Ambient air temperature for operation -25…55 °C
Ambient air temperature for storage -40…70 °C

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 10.5 cm
Package 1 Width 13.5 cm
Package 1 Length 16.5 cm
Package 1 Weight 438 g
Unit Type of Package 2 S03
Number of Units in Package 2 8
Package 2 Height 30 cm
Package 2 Width 30 cm
Package 2 Length 40 cm
Package 2 Weight 4.177 kg

Contractual warranty

Warranty 18 months

Documentation

Product Datasheet

User guide

Instruction sheet

Catalogue

CAD

Environmental disclosure

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible