Description for K115F003UP Schneider Electric

K115F003UP Schneider Electric - cam changeover switch - 3-pole - 60° - 115 A - screw mounting

Extended Description for K115F003UP Schneider Electric

K115F003UP Schneider Electric - This metal head cam switch is designed to meet most industrial and process control application thanks to a compact size and has several selection functions,It has a 60 or 300 degree between its switching positions,It works at a rated conventional free air thermal current of 115 A

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Available on back order
4 - 6 W.Weeks
£179.20 Exc. VAT
£215.05 Inc. VAT

Main

range of product Harmony K
product or component type Complete cam switch
Component name K115
[Ith] conventional free air thermal current 115 A
Mounting location Front
Fixing mode 4 holes
Cam switch head type With front plate 88 x 88 mm
Type of operator Black handle
Rotary handle padlocking Without
Presentation of legend With metallic legend, 1 - 0 - 2 black marking
Cam switch function Changeover switch
Return Without
Off position With Off position
Poles description 3P
Switching positions Right: 0° - 60°,Left: 0° - 300°
IP degree of protection IP40 conforming to IEC 60529

Complementary

Switching angle 60 °
[Ui] rated insulation voltage 690 V (pollution degree 3) conforming to IEC 60947-1
Rated operational power in W 13000 W AC-3, 380/440 V 1 phase conforming to IEC 60947-3,15000 W AC-23A, 220/240 V 1 phase conforming to IEC 60947-3,15000 W AC-3, 220/240 V 3 phases conforming to IEC 60947-3,22000 W AC-23A, 380/440 V 1 phase conforming to IEC 60947-3,30000 W AC-23A, 220/240 V 3 phases conforming to IEC 60947-3,30000 W AC-3, 380/440 V 3 phases conforming to IEC 60947-3,30000 W AC-3, 660/690 V 3 phases conforming to IEC 60947-3,3700 W AC-3, 110 V 1 phase conforming to IEC 60947-3,45000 W AC-23A, 380/440 V 3 phases conforming to IEC 60947-3,5500 W AC-23A, 110 V 1 phase conforming to IEC 60947-3,65000 W AC-23A, 660/690 V 3 phases conforming to IEC 60947-3,7500 W AC-3, 220/240 V 1 phase conforming to IEC 60947-3
[Ie] rated operational current AC 100 A AC-21A conforming to IEC 60947-3
Short-circuit current 15000 A
Short-circuit protection 125 A cartridge fuse, type gG
[Uimp] rated impulse withstand voltage 6 kV conforming to EN 947-1,6 kV conforming to IEC 947-1
Contact operation Slow-break
Positive opening With
Electrical connection Captive screw clamp terminals flexible, clamping capacity: 1 x 25 mm²,Captive screw clamp terminals solid, clamping capacity: 1 x 35 mm²
Tightening torque 2.5 N.m
Switching capacity in mA 100000 mA DC at 140 V 3 contact(s) for resistive load (T = 1 ms),100000 mA DC at 24 V 1 contact(s) for inductive load (T = 50 ms),100000 mA DC at 48 V 1 contact(s) for resistive load (T = 1 ms),100000 mA DC at 48 V 2 contact(s) for inductive load (T = 50 ms),100000 mA DC at 70 V 3 contact(s) for inductive load (T = 50 ms),100000 mA DC at 95 V 2 contact(s) for resistive load (T = 1 ms),115000 mA DC at 24 V 1 contact(s) for resistive load (T = 1 ms),115000 mA DC at 48 V 2 contact(s) for resistive load (T = 1 ms),115000 mA DC at 70 V 3 contact(s) for resistive load (T = 1 ms),33000 mA DC at 30 V 1 contact(s) for inductive load (T = 50 ms),33000 mA DC at 60 V 2 contact(s) for inductive load (T = 50 ms),33000 mA DC at 90 V 3 contact(s) for inductive load (T = 50 ms)
Mechanical durability 300000 cycles
CAD overall width 88 mm
CAD overall height 88 mm
CAD overall depth 154 mm
net weight 0.645 kg

Environment

Standards IEC 60947-3
Product certifications CULus 120 V 5 hp 1 phase,CULus 240 V 10 hp 1 phase,CULus 240 V 20 hp 3 phases,CULus 480 V 30 hp 3 phases
Protective treatment TC
Ambient air temperature for operation -25…55 °C
Ambient air temperature for storage -40…70 °C
Overvoltage category Class II conforming to IEC 60536,Class II conforming to NF C 20-030

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 23.5 cm
Package 1 Width 9.8 cm
Package 1 Length 9.8 cm
Package 1 Weight 975.0 g
Unit Type of Package 2 S03
Number of Units in Package 2 5
Package 2 Height 30.0 cm
Package 2 Width 30.0 cm
Package 2 Length 40.0 cm
Package 2 Weight 5.418 kg

Contractual warranty

Warranty 18 months

Documentation

Product Datasheet

Instruction sheet