Description for KNB16CN5 Schneider Electric

KNB16CN5 Schneider Electric - TAPOFF UNIT 16A FOR DIN FUSES

Extended Description for KNB16CN5 Schneider Electric

KNB16CN5 Schneider Electric - This is a 4 poles tap off unit with fuse holders for Canalis KN busbar trunking with plug-in outlets.,It is used for rapid connection of loads or secondary lines in compliance with installation standards IEC 60364 and regulations concerning TT, TNS and TNC earthing systems.,The rated operational current is 16A.,The rated operational voltage is from 230VAC to 500VAC 50/60Hz depending on protective device.,It is be equipped with fuse holders for DIN fuse Neozed E14 type (fuses not supplied).,The tap-off unit polarity is 3L+N+PE or 3L + PE, disconnection by drawing out.,Tap-off unit cover can be lead sealed to prevent circuit breaker switching by unauthorised persons.,It is suitable for TT, TN-S and TN-C earthing system.,The colour is white RAL 9001.,Cable clamp is supplied.,It provides IP55 protection degree conforming to EN/IEC 60529.,It provides IK08 mechanical impact degree conforming to EN/IEC 62262.,It is compliant with IEC 61439-1 and IEC 61439-6.,It is compliant with Schneider Green Premium ecolabel (RoHS, REACh, Product Environmental Profile, End of Life Instructions.).

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Available on back order
4 - 6 W.Weeks
£29.49 Exc. VAT
£35.39 Inc. VAT

Main

range of product Canalis
Range compatibility Canalis KN busbar trunking
product or component type Tap-off unit
busbar trunking compatibility Canalis KN busbar trunkingplug-in
[Ie] rated operational current 16 A at 35 °C
protection type fuse isolator: Neozed fuse, size E14 conforming to DIN
Provided equipment fuse to be ordered separately, cable clamp
Mounting mode Plug-in with fixed polarity
tap-off unit polarity 3L+N+PE,3L+PE
Colour White (RAL 9001)

Complementary

device application Low power distribution
[Ue] rated operational voltage 230...500 V depending on protective device
[Uimp] rated impulse withstand voltage 4.6 kV
[Ui] rated insulation voltage 500 V depending on protective device
Network frequency 50/60 Hz
Electrical connection Cable clamp terminal - ISO32 4 mm² flexible,Cable clamp terminal - ISO32 6 mm² rigid
door/cover opening side Front
Tap-off unit disconnection mode By drawing out
Standards IEC 61439-1,IEC 61439-6
Width 135 mm
Depth 90 mm
Height 165 mm
net weight 0.6 kg

Environment

IP degree of protection IP55 conforming to IEC 60529
IK degree of protection IK08 conforming to IEC 62262

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 12.600 cm
Package 1 Width 16.600 cm
Package 1 Length 13.600 cm
Package 1 Weight 920.000 g
Unit Type of Package 2 P12
Number of Units in Package 2 144
Package 2 Height 80.000 cm
Package 2 Width 80.000 cm
Package 2 Length 120.000 cm
Package 2 Weight 133.000 kg

Contractual warranty

Warranty 18 months

Documentation

Product Datasheet

Instruction sheet

Catalogue

CAD

Environmental disclosure

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible