Description for LC1D115004P5 Schneider Electric

LC1D115004P5 Schneider Electric - TeSys D contactor - 4P(4 NO) - AC-1 - <= 440 V 200 A - 230 V AC 50 Hz coil

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Available on back order
4 - 6 W.Weeks
£239.77 Exc. VAT
£287.73 Inc. VAT

Main

Range TeSys
range of product TeSys Deca
product or component type Contactor
Device short name LC1D
Contactor application Resistive load
Utilisation category AC-1,AC-3,AC-3e,AC-4
Poles description 4P
[Ue] rated operational voltage Power circuit: <= 1000 V AC 25...400 Hz,Power circuit: <= 460 V DC
[Ie] rated operational current 200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
[Uc] control circuit voltage 230 V AC 50 Hz

Complementary

compatibility code LC1D
Pole contact composition 4 NO
Protective cover With
[Ith] conventional free air thermal current 200 A (at 60 °C) for power circuit
Irms rated making capacity 1260 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity 1100 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 250 A 40 °C - 10 min for power circuit,550 A 40 °C - 1 min for power circuit,950 A 40 °C - 10 s for power circuit,1100 A 40 °C - 1 s for power circuit
Associated fuse rating 250 A gG at <= 690 V coordination type 1 for power circuit,200 A gG at <= 690 V coordination type 2 for power circuit
Average impedance 0.6 mOhm - Ith 200 A 50 Hz for power circuit
Power dissipation per pole 24 W AC-1
[Ui] rated insulation voltage Power circuit: 600 V CSA certified,Power circuit: 600 V UL certified,Power circuit: 1000 V conforming to IEC 60947-4-1
Overvoltage category III
Pollution degree 3
[Uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947
Safety reliability level B10d = 684932 cycles contactor with nominal load conforming to EN/ISO 13849-1,B10d = 10000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability 8 Mcycles
Electrical durability 0.8 Mcycles 200 A AC-1 at Ue <= 440 V
Control circuit type AC at 50 Hz
Coil technology Without built-in suppressor module
Control circuit voltage limits 0.3...0.6 Uc (-40…70 °C):drop-out AC 50 Hz,0.85...1.1 Uc (-40…55 °C):operational AC 50 Hz,1...1.1 Uc (55…70 °C):operational AC 50 Hz
Inrush power in VA 300 VA 50 Hz cos phi 0.8 (at 20 °C)
Hold-in power consumption in VA 22 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation 3…8 W at 50 Hz
Operating time 6...20 ms opening,20...50 ms closing
Maximum operating rate 2400 cyc/h 60 °C
Connections - terminals Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end,Control circuit: screw clamp terminals 1 1…2.5 mm² - cable stiffness: flexible with cable end,Control circuit: screw clamp terminals 1 1…2.5 mm² - cable stiffness: flexible without cable end,Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible without cable end,Control circuit: screw clamp terminals 1 1…2.5 mm² - cable stiffness: solid without cable end,Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: solid without cable end,Power circuit: connector 1 10…120 mm² - cable stiffness: flexible without cable end,Power circuit: connector 2 10…50 mm² - cable stiffness: flexible without cable end,Power circuit: connector 1 10…120 mm² - cable stiffness: flexible with cable end,Power circuit: connector 2 10…50 mm² - cable stiffness: flexible with cable end,Power circuit: connector 1 10…120 mm² - cable stiffness: solid without cable end,Power circuit: connector 2 10…50 mm² - cable stiffness: solid without cable end
Tightening torque Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm,Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2,Power circuit: 12 N.m - on connector hexagonal screw head 4 mm,Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
mounting support Plate,Rail

Environment

Standards CSA C22.2 No 14,EN 60947-4-1,EN 60947-5-1,IEC 60947-4-1,IEC 60947-5-1,UL 508
Product certifications CCC,GOST,GL,RINA,LROS (Lloyds register of shipping),UL,BV,DNV,CSA,UKCA
IP degree of protection IP20 front face conforming to IEC 60529
Protective treatment TH conforming to IEC 60068-2-30
Climatic withstand conforming to IACS E10 exposure to damp heat, conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Permissible ambient air temperature around the device -40…60 °C,60…70 °C with derating
Operating altitude 0...3000 m
Fire resistance 850 °C conforming to IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Vibrations contactor open (2 Gn, 5...300 Hz) ,Vibrations contactor closed (4 Gn, 5...300 Hz) ,Shocks contactor closed (15 Gn for 11 ms) ,Shocks contactor open (6 Gn for 11 ms)
Height 158 mm
Width 150 mm
Depth 132 mm
net weight 2.86 kg

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 19.0 cm
Package 1 Width 20.5 cm
Package 1 Length 21.0 cm
Package 1 Weight 2.969 kg

Contractual warranty

Warranty 18 months

Documentation

Product Datasheet

Instruction sheet

Catalogue