This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Schneider Electric

LC1D115LE7

LC1D115LE7 Schneider Electric

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for LC1D115LE7 Schneider Electric

LC1D115LE7 Schneider Electric - TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 115 A - 208 V AC 50/60 Hz coil

Extended Description for LC1D115LE7 Schneider Electric

LC1D115LE7 Schneider Electric - TeSys Deca contactors have been designed for perfect integration into control systems.,They can be used to create motor starters for almost any type of application.,TeSys Deca contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps.,This 115A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel.,Contactors have both Horsepower and Kw motor rating for international acceptance.,Contactor is rated for 30HP at 200 to 208VAC, 40HP at 240VAC, 75HP at 480VAC and 100HP at 600VAC three phase.,When used with a 480VAC up to 250A circuit breaker, this contactor can have a SCCR up to 100kA.,When used with a 600VAC up to 250A circuit breaker, this contactor can have a SCCR up to 50kA.,When used with 600VAC Class J or CC fuses up to 250A, this contactor can have a SCCR up to 100kA.,Contactor is supplied with a 208 VAC 50/60 Hz coil.,Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified.,Screw clamp terminals are used for load and auxiliary connections.,An extensive line of accessories makes it easy to meet the requirements of most applications.,The contactor is 6.22 inches tall, 4.72 inches wide and 5.35 inches deep. It weighs 5.51 lbs.,Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Available on back order
4 - 6 W.Weeks
£375.43 Exc. VAT
£450.52 Inc. VAT

Main

Range TeSys
range of product TeSys Deca
product or component type Contactor
Device short name LC1D
Contactor application Resistive load,Motor control
Utilisation category AC-1,AC-3,AC-3e,AC-4
Poles description 3P
[Ue] rated operational voltage Power circuit: <= 1000 V AC 25...400 Hz,Power circuit: <= 300 V DC
[Ie] rated operational current 200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit,115 A (at <60 °C) at <= 440 V AC AC-3 for power circuit,115 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
[Uc] control circuit voltage 208 V AC 50/60 Hz

Complementary

Motor power kW 30 kW at 220...230 V AC 50/60 Hz (AC-3),55 kW at 380...400 V AC 50/60 Hz (AC-3),59 kW at 415...440 V AC 50/60 Hz (AC-3),75 kW at 500 V AC 50/60 Hz (AC-3),80 kW at 660...690 V AC 50/60 Hz (AC-3),65 kW at 1000 V AC 50/60 Hz (AC-3),18.5 kW at 400 V AC 50/60 Hz (AC-4),30 kW at 220...230 V AC 50/60 Hz (AC-3e),55 kW at 380...400 V AC 50/60 Hz (AC-3e),59 kW at 415...440 V AC 50/60 Hz (AC-3e),75 kW at 500 V AC 50/60 Hz (AC-3e),80 kW at 660...690 V AC 50/60 Hz (AC-3e),65 kW at 1000 V AC 50/60 Hz (AC-3e)
Motor power hp 30 hp at 200/208 V AC 50/60 Hz for 3 phases motors,40 hp at 230/240 V AC 50/60 Hz for 3 phases motors,75 hp at 460/480 V AC 50/60 Hz for 3 phases motors,100 hp at 575/600 V AC 50/60 Hz for 3 phases motors
compatibility code LC1D
Pole contact composition 3 NO
Protective cover With
[Ith] conventional free air thermal current 200 A (at 60 °C) for power circuit
Irms rated making capacity 1260 A at 440 V for power circuit conforming to IEC 60947,140 A AC for signalling circuit conforming to IEC 60947-5-1,250 A DC for signalling circuit conforming to IEC 60947-5-1
Rated breaking capacity 1100 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 250 A 40 °C - 10 min for power circuit,550 A 40 °C - 1 min for power circuit,950 A 40 °C - 10 s for power circuit,1100 A 40 °C - 1 s for power circuit,100 A - 1 s for signalling circuit,120 A - 500 ms for signalling circuit,140 A - 100 ms for signalling circuit
Associated fuse rating 250 A gG at <= 690 V coordination type 1 for power circuit,200 A gG at <= 690 V coordination type 2 for power circuit,10 A gG for signalling circuit
Average impedance 0.6 mOhm - Ith 200 A 50 Hz for power circuit
Power dissipation per pole 24 W AC-1,7.9 W AC-3,7.9 W AC-3e
[Ui] rated insulation voltage Power circuit: 600 V CSA certified,Power circuit: 600 V UL certified,Power circuit: 1000 V conforming to IEC 60947-4-1,Signalling circuit: 690 V conforming to IEC 60947-1,Signalling circuit: 600 V CSA certified,Signalling circuit: 600 V UL certified
Overvoltage category III
Pollution degree 3
[Uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947
Safety reliability level B10d = 684932 cycles contactor with nominal load conforming to EN/ISO 13849-1,B10d = 10000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability 8 Mcycles
Electrical durability 0.8 Mcycles 200 A AC-1 at Ue <= 440 V,0.95 Mcycles 115 A AC-3 at Ue <= 440 V,0.95 Mcycles 115 A AC-3e at Ue <= 440 V
Control circuit type AC at 50/60 Hz
Coil technology Built-in bidirectional peak limiting diode suppressor
Control circuit voltage limits 0.3...0.5 Uc (-40…70 °C):drop-out AC 50/60 Hz,0.8...1.15 Uc (-40…55 °C):operational AC 50/60 Hz,1...1.15 Uc (55…70 °C):operational AC 50/60 Hz
Inrush power in VA 280…350 VA 60 Hz cos phi 0.8 (at 20 °C),280…350 VA 50 Hz cos phi 0.8 (at 20 °C)
Hold-in power consumption in VA 2…18 VA 60 Hz cos phi 0.3 (at 20 °C),2…18 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation 3…8 W at 50/60 Hz
Operating time 6...20 ms opening,20...50 ms closing
Maximum operating rate 2400 cyc/h 60 °C
Maximum operating rate 2400 cyc/h at 60 °C
Connections - terminals Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end,Control circuit: screw clamp terminals 1 1…2.5 mm² - cable stiffness: flexible with cable end,Control circuit: screw clamp terminals 1 1…2.5 mm² - cable stiffness: flexible without cable end,Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible without cable end,Control circuit: screw clamp terminals 1 1…2.5 mm² - cable stiffness: solid without cable end,Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: solid without cable end,Power circuit: connector 1 10…120 mm² - cable stiffness: flexible without cable end,Power circuit: connector 2 10…50 mm² - cable stiffness: flexible without cable end,Power circuit: connector 1 10…120 mm² - cable stiffness: flexible with cable end,Power circuit: connector 2 10…50 mm² - cable stiffness: flexible with cable end,Power circuit: connector 1 10…120 mm² - cable stiffness: solid without cable end,Power circuit: connector 2 10…50 mm² - cable stiffness: solid without cable end
Tightening torque Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm,Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2,Power circuit: 12 N.m - on connector hexagonal screw head 4 mm,Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
Auxiliary contact composition 1 NO + 1 NC
Auxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1, type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency 25...400 Hz
Minimum switching voltage 17 V for signalling circuit
Minimum switching current 5 mA for signalling circuit
Insulation resistance > 10 MOhm for signalling circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contact,1.5 ms on energisation between NC and NO contact
mounting support Rail,Plate

Environment

Standards CSA C22.2 No 14,EN 60947-4-1,IEC 60947-4-1,IEC 60335-1:Clause 30.2,IEC 60335-2-40:Annex JJ,UL 60335-2-40:Annex JJ,UL 60947-4-1,CSA C22.2 No 60947-4-1,JIS C8201-4-1
Product certifications UL,CSA,CCC,UKCA,CE,EAC,Marine
IP degree of protection IP20 front face conforming to IEC 60529
Protective treatment TH conforming to IEC 60068-2-30
Climatic withstand conforming to IACS E10 exposure to damp heat, conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Permissible ambient air temperature around the device -40…60 °C,60…70 °C with derating
Operating altitude 0...3000 m
Fire resistance 850 °C conforming to IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Vibrations contactor open (2 Gn, 5...300 Hz) ,Vibrations contactor closed (4 Gn, 5...300 Hz) ,Shocks contactor closed (15 Gn for 11 ms) ,Shocks contactor open (6 Gn for 11 ms)
Height 158 mm
Width 120 mm
Depth 136 mm
net weight 2.5 kg

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 19.0 cm
Package 1 Width 17.5 cm
Package 1 Length 21.0 cm
Package 1 Weight 2.543 kg

Contractual warranty

Warranty 18 months

Documentation

Product Datasheet

Instruction sheet

CAD

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible