This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Schneider Electric

LC1D1210P7

LC1D1210P7 Schneider Electric

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for LC1D1210P7 Schneider Electric

LC1D1210P7 Schneider Electric - contactor TeSys Deca - 3 poles - AC-3 690 V 12 A - coil 230 V AC

Free Delivery to UK Mainland on orders over £25

Main

Range TeSys
range of product TeSys D
product or component type Contactor
Device short name LC1D
Contactor application Resistive load,Motor control
Utilisation category AC-1,AC-3
Poles description 3P
[Ue] rated operational voltage Power circuit: 690 V AC 25...400 Hz
[Ie] rated operational current 25 A (at <60 °C) at 440 V AC AC-1 for power circuit,12 A (at <60 °C) at 440 V AC AC-3 for power circuit
[Uc] control circuit voltage 230 V AC 50/60 Hz

Complementary

Motor power kW 7.5 kW at 500 V AC 50/60 Hz,7.5 kW at 660...690 V AC 50/60 Hz,5.5 kW at 380...400 V AC 50/60 Hz,5.5 kW at 415...440 V AC 50/60 Hz,3 kW at 220...230 V AC 50/60 Hz
Motor power hp 1 hp at 115 V AC 60 Hz for 1 phase motors conforming to CSA,1 hp at 115 V AC 60 Hz for 1 phase motors conforming to UL,10 hp at 575/600 V AC 60 Hz for 3 phases motors conforming to CSA,10 hp at 575/600 V AC 60 Hz for 3 phases motors conforming to UL,2 hp at 230/240 V AC 60 Hz for 1 phase motors conforming to CSA,2 hp at 230/240 V AC 60 Hz for 1 phase motors conforming to UL,3 hp at 200/208 V AC 60 Hz for 3 phases motors conforming to CSA,3 hp at 200/208 V AC 60 Hz for 3 phases motors conforming to UL,3 hp at 230/240 V AC 60 Hz for 3 phases motors conforming to CSA,3 hp at 230/240 V AC 60 Hz for 3 phases motors conforming to UL,7.5 hp at 460/480 V AC 60 Hz for 3 phases motors conforming to CSA,7.5 hp at 460/480 V AC 60 Hz for 3 phases motors conforming to UL
compatibility code LC1D
Pole contact composition 3 NO
Protective cover With
[Ith] conventional free air thermal current 10 A (at 60 °C) for control circuit,25 A (at 60 °C) for power circuit
Irms rated making capacity 250 A at 440 V AC for power circuit conforming to IEC 60947,140 A AC for control circuit conforming to IEC 60947-5-1
Rated breaking capacity 250 kA at 440 V for power circuit conforming to IEC 60947
Associated fuse rating 10 A gG for control circuit conforming to IEC 60947-5-1,25 A at 690 V coordination type 2 for power circuit,40 A at 690 V coordination type 1 for power circuit
Average impedance 2.5 mOhm - Ith 25 A 50 Hz for power circuit
Power dissipation per pole 0.36 W AC-3,1.56 W AC-1
[Ui] rated insulation voltage Control circuit: 600 V CSA certified,Control circuit: 600 V UL certified,Power circuit: 600 V CSA certified,Power circuit: 600 V UL certified,Control circuit: 690 V conforming to IEC 60947-4-1,Power circuit: 690 V conforming to IEC 60947-4-1
Overvoltage category III
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1,B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability 15000000 cycles
Control circuit type AC at 50/60 Hz
Coil technology Without built-in bidirectional peak limiting diode suppressor
Control circuit voltage limits 0.3...0.6 Uc (60 °C):drop-out AC 50/60 Hz,0.8...1.1 Uc (60 °C):operational AC 50/60 Hz
Inrush power in VA 70 VA cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA 7 VA 50 Hz cos phi 0.3 (at 20 °C),7.5 VA 60 Hz cos phi 0.3 (at 20 °C)
Heat dissipation 2…3 W at 50/60 Hz for control circuit
Operating time 4...19 ms opening,12...22 ms closing
Maximum operating rate 3600 cyc/h 60 °C
Connections - terminals Control circuit: screw clamp terminal 1 1…4 mm² - cable stiffness: solid without cable end,Control circuit: screw clamp terminal 2 1…4 mm² - cable stiffness: solid without cable end,Control circuit: screw clamp terminal 1 1…4 mm² - cable stiffness: flexible without cable end,Control circuit: screw clamp terminal 2 1…4 mm² - cable stiffness: flexible without cable end,Control circuit: screw clamp terminal 1 1…4 mm² - cable stiffness: flexible with cable end,Control circuit: screw clamp terminal 2 1…2.5 mm² - cable stiffness: flexible with cable end,Power circuit: screw clamp terminal 1 1…4 mm² - cable stiffness: solid without cable end,Power circuit: screw clamp terminal 2 1…4 mm² - cable stiffness: solid without cable end,Power circuit: screw clamp terminal 1 1…4 mm² - cable stiffness: flexible without cable end,Power circuit: screw clamp terminal 2 1…4 mm² - cable stiffness: flexible without cable end,Power circuit: screw clamp terminal 1 1…4 mm² - cable stiffness: flexible with cable end,Power circuit: screw clamp terminal 2 1…2.5 mm² - cable stiffness: flexible with cable end
Tightening torque Power circuit: 1.7 N.m - on screw clamp terminal - with screwdriver flat Ø 6 mm hexagonal screw head ,Power circuit: 1.7 N.m - on screw clamp terminal - with screwdriver Philips No 2 hexagonal screw head ,Control circuit: 1.7 N.m - on screw clamp terminal - with screwdriver flat Ø 6 mm,Control circuit: 1.7 N.m - on screw clamp terminal - with screwdriver Philips No 2
Auxiliary contact composition 1 NO
Auxiliary contacts type type mirror contact 1 NC conforming to IEC 60947-4-1, type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
Minimum switching voltage 17 V for control circuit
Minimum switching current 5 mA for control circuit
Insulation resistance > 10 MOhm for control circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contacts,1.5 ms on energisation between NC and NO contacts
mounting support Rail,Plate

Environment

Standards CSA C22.2 No 14,EN/IEC 60947-5-1,UL 508,EN/IEC 60947-4-1
Product certifications CCC,CSA,GL,RINA,UL,BV,DNV,LROS (Lloyds register of shipping)
IP degree of protection IP2X conforming to VDE 0106
Protective treatment TH conforming to IEC 60068-2-30
Climatic withstand conforming to IACS E10 exposure to damp heat, conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Permissible ambient air temperature around the device -60…80 °C storage,-40…60 °C operation,60…70 °C with derating
Operating altitude 3000 m without derating
Fire resistance 850 °C conforming to IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Shocks contactor opened (10 Gn) ,Shocks contactor closed (15 gn) ,Vibrations contactor opened (2 Gn, 5...300 Hz) ,Vibrations contactor closed (4 Gn, 5...300 Hz)
Height 77 mm
Width 45 mm
Depth 84 mm

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1

Contractual warranty

Warranty 18 months