This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Schneider Electric

LC1D50AJ5

LC1D50AJ5 Schneider Electric

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for LC1D50AJ5 Schneider Electric

LC1D50AJ5 Schneider Electric - TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A - 12 V AC 50 Hz coil

Extended Description for LC1D50AJ5 Schneider Electric

LC1D50AJ5 Schneider Electric - TeSys D contactor, 3 poles (3NO), for motor control applications up to 50A/440V AC-3/3e (22kW@400V).,It provides a 12V 50Hz AC coil, 1NO+1NC built-in auxiliary contacts (NC mirror certified), power connection by EverLink BTR screw connectors, control connection by screw clamp terminals.,For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability.,Compact (55mm width), DIN-rail mounting or screw fixing.,Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Available on back order
4 - 6 W.Weeks
£100.62 Exc. VAT
£120.75 Inc. VAT

Main

Range TeSys,TeSys Deca
range of product TeSys Deca
product or component type Contactor
Device short name LC1D
Contactor application Motor control,Resistive load
Utilisation category AC-4,AC-1,AC-3,AC-3e
Poles description 3P
[Ue] rated operational voltage Power circuit: <= 690 V AC 25...400 Hz,Power circuit: <= 300 V DC
[Ie] rated operational current 50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit,80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit,50 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
[Uc] control circuit voltage 12 V AC 50 Hz

Complementary

Motor power kW 15 kW at 220...230 V AC 50/60 Hz (AC-3),22 kW at 380...400 V AC 50/60 Hz (AC-3),30 kW at 500 V AC 50/60 Hz (AC-3),33 kW at 660...690 V AC 50/60 Hz (AC-3),25 kW at 415 V AC 50/60 Hz (AC-3),30 kW at 440 V AC 50/60 Hz (AC-3),11 kW at 400 V AC 50/60 Hz (AC-4),15 kW at 220...230 V AC 50/60 Hz (AC-3e),22 kW at 380...400 V AC 50/60 Hz (AC-3e),30 kW at 500 V AC 50/60 Hz (AC-3e),33 kW at 660...690 V AC 50/60 Hz (AC-3e),25 kW at 415 V AC 50/60 Hz (AC-3e),30 kW at 440 V AC 50/60 Hz (AC-3e)
Motor power hp 3 hp at 115 V AC 50/60 Hz for 1 phase motors,7.5 hp at 230/240 V AC 50/60 Hz for 1 phase motors,15 hp at 200/208 V AC 50/60 Hz for 3 phases motors,15 hp at 230/240 V AC 50/60 Hz for 3 phases motors,40 hp at 460/480 V AC 50/60 Hz for 3 phases motors,40 hp at 575/600 V AC 50/60 Hz for 3 phases motors
compatibility code LC1D
Pole contact composition 3 NO
Protective cover With
[Ith] conventional free air thermal current 10 A (at 60 °C) for signalling circuit,80 A (at 60 °C) for power circuit
Irms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1,250 A DC for signalling circuit conforming to IEC 60947-5-1,900 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity 900 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 400 A 40 °C - 10 s for power circuit,810 A 40 °C - 1 s for power circuit,84 A 40 °C - 10 min for power circuit,208 A 40 °C - 1 min for power circuit,100 A - 1 s for signalling circuit,120 A - 500 ms for signalling circuit,140 A - 100 ms for signalling circuit
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1,100 A gG at <= 690 V coordination type 1 for power circuit,100 A gG at <= 690 V coordination type 2 for power circuit
Average impedance 1.5 mOhm - Ith 80 A 50 Hz for power circuit
Power dissipation per pole 3.7 W AC-3,9.6 W AC-1,3.7 W AC-3e
[Ui] rated insulation voltage Power circuit: 600 V CSA certified,Power circuit: 600 V UL certified,Signalling circuit: 690 V conforming to IEC 60947-1,Signalling circuit: 600 V CSA certified,Signalling circuit: 600 V UL certified,Power circuit: 690 V conforming to IEC 60947-4-1
Overvoltage category III
Pollution degree 3
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1,B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability 6 Mcycles
Electrical durability 1.45 Mcycles 50 A AC-3 at Ue <= 440 V,1.1 Mcycles 80 A AC-1 at Ue <= 440 V,1.45 Mcycles 50 A AC-3e at Ue <= 440 V
Control circuit type AC at 50 Hz
Coil technology Without built-in suppressor module
Control circuit voltage limits 0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz,0.3...0.6 Uc (-40…70 °C):drop-out AC 50 Hz,1...1.1 Uc (60…70 °C):operational AC 50 Hz
Inrush power in VA 160 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA 15 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation 4…5 W at 50 Hz
Operating time 4...19 ms opening,12...26 ms closing
Maximum operating rate 3600 cyc/h 60 °C
Maximum operating rate 3600 cyc/h at 60 °C
Connections - terminals Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end,Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end,Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end,Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end,Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end,Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end,Power circuit: EverLink BTR screw connectors 1 1…35 mm² - cable stiffness: flexible without cable end,Power circuit: EverLink BTR screw connectors 2 1…25 mm² - cable stiffness: flexible without cable end,Power circuit: EverLink BTR screw connectors 1 1…35 mm² - cable stiffness: flexible with cable end,Power circuit: EverLink BTR screw connectors 2 1…25 mm² - cable stiffness: flexible with cable end,Power circuit: EverLink BTR screw connectors 1 1…35 mm² - cable stiffness: solid without cable end,Power circuit: EverLink BTR screw connectors 2 1…25 mm² - cable stiffness: solid without cable end
Tightening torque Control circuit: 1.7 N.m - on EverLink BTR screw connectors - with screwdriver flat Ø 6 mm,Control circuit: 1.7 N.m - on EverLink BTR screw connectors - with screwdriver Philips No 2,Power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25…35 mm² hexagonal screw head 4 mm,Power circuit: 5 N.m - on EverLink BTR screw connectors - cable 1…25 mm² hexagonal screw head 4 mm,Control circuit: 1.7 N.m - on EverLink BTR screw connectors - with screwdriver pozidriv No 2,Power circuit: 2.5 N.m - on EverLink BTR screw connectors - with screwdriver pozidriv No 2
Auxiliary contact composition 1 NO + 1 NC
Auxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1, type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency 25...400 Hz
Minimum switching voltage 17 V for signalling circuit
Minimum switching current 5 mA for signalling circuit
Insulation resistance > 10 MOhm for signalling circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contact,1.5 ms on energisation between NC and NO contact
mounting support Plate,Rail

Environment

Standards EN 60947-4-1,EN 60947-5-1,IEC 60947-4-1,IEC 60947-5-1,CSA C22.2 No 14,UL 60947-4-1,IEC 60335-2-40:Annex JJ,UL 60335-2-40:Annex JJ,IEC 60335-1:Clause 30.2
Product certifications CCC,UL,CB Scheme,CSA,CE,UKCA,Marine,EAC
IP degree of protection IP20 front face conforming to IEC 60529
Protective treatment TH conforming to IEC 60068-2-30
Climatic withstand conforming to IACS E10 exposure to damp heat, conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Permissible ambient air temperature around the device -40…60 °C,60…70 °C with derating
Operating altitude 0...3000 m
Fire resistance 850 °C conforming to IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Vibrations contactor open (2 Gn, 5...300 Hz) ,Vibrations contactor closed (4 Gn, 5...300 Hz) ,Shocks contactor closed (15 Gn for 11 ms) ,Shocks contactor open (10 Gn for 11 ms)
Height 122 mm
Width 55 mm
Depth 120 mm
net weight 0.855 kg

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 6.0 cm
Package 1 Width 14.0 cm
Package 1 Length 15.0 cm
Package 1 Weight 850.0 g

Contractual warranty

Warranty 18 months

Documentation

Product Datasheet

Instruction sheet

Catalogue

CAD

Environmental disclosure

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible