Description for LC1D65004F7 Schneider Electric

LC1D65004F7 Schneider Electric - CONTACTOR 575VAC 65AMP IEC +OPTIONS

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Available on back order
4 - 6 W.Weeks
£231.81 Exc. VAT
£278.17 Inc. VAT

Main

range of product TeSys Deca
product or component type Contactor
Device short name LC1D
Contactor application Resistive load
Utilisation category AC-1,AC-3,AC-3e,AC-4
Poles description 4P
[Ue] rated operational voltage Power circuit: <= 690 V AC 25...400 Hz
[Ie] rated operational current 80 A (at <60 °C) AC AC-1 for power circuit
[Uc] control circuit voltage 110 V AC 50/60 Hz

Complementary

Motor power hp 10 hp at 230/240 V AC 60 Hz for 1 phase motors conforming to CSA,10 hp at 230/240 V AC 60 Hz for 1 phase motors conforming to UL,20 hp at 200/208 V AC 60 Hz for 3 phases motors conforming to CSA,20 hp at 200/208 V AC 60 Hz for 3 phases motors conforming to UL,20 hp at 230/240 V AC 60 Hz for 3 phases motors conforming to CSA,20 hp at 230/240 V AC 60 Hz for 3 phases motors conforming to UL,5 hp at 115 V AC 60 Hz for 1 phase motors conforming to CSA,5 hp at 115 V AC 60 Hz for 1 phase motors conforming to UL,50 hp at 460/480 V AC 60 Hz for 3 phases motors conforming to CSA,50 hp at 460/480 V AC 60 Hz for 3 phases motors conforming to UL,50 hp at 575/600 V AC 60 Hz for 3 phases motors conforming to CSA,50 hp at 575/600 V AC 60 Hz for 3 phases motors conforming to UL
compatibility code LC1D
Pole contact composition 4 NO
Protective cover With
[Ith] conventional free air thermal current 10 A (at 60 °C) for control circuit,80 A (at 60 °C) for power circuit
Irms rated making capacity 1000 A at 440 V for power circuit conforming to IEC 60947,140 A AC for control circuit conforming to IEC 60947-5-1
Rated breaking capacity 1000 A at 440 V for power circuit conforming to IEC 60947
Associated fuse rating 10 A gG for control circuit conforming to IEC 60947-5-1,125 A gG at <= 690 V coordination type 2 for power circuit,160 A gG at <= 690 V coordination type 1 for power circuit
Average impedance 1 mOhm - Ith 80 A 50 Hz for power circuit
Power dissipation per pole 6.4 W AC-1
[Ui] rated insulation voltage Control circuit: 600 V CSA certified,Control circuit: 600 V UL certified,Power circuit: 600 V CSA certified,Power circuit: 600 V UL certified,Control circuit: 690 V conforming to IEC 60947-1,Power circuit: 690 V conforming to IEC 60947-1
Overvoltage category III
[Uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1,B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability 6000000 cycles
Control circuit type AC at 50/60 Hz standard
Coil technology Without built-in bidirectional peak limiting diode suppressor
Control circuit voltage limits 0.3...0.6 Uc (60 °C):drop-out AC 50/60 Hz,0.8...1.1 Uc (60 °C):operational AC 50 Hz,0.85...1.1 Uc (60 °C):operational AC 60 Hz
Inrush power in VA 140 VA cos phi 0.75 (at 20 °C),160 VA cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA 13 VA 60 Hz cos phi 0.3 (at 20 °C),15 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation 4…5 W at 50/60 Hz for control circuit
Operating time 12...26 ms closing,4...19 ms opening
Maximum operating rate 3600 cyc/h 60 °C
Connections - terminals Control circuit: screw clamp terminal 1 1…4 mm² - cable stiffness: solid without cable end,Control circuit: screw clamp terminal 2 1…4 mm² - cable stiffness: flexible without cable end,Control circuit: screw clamp terminal 2 1…4 mm² - cable stiffness: solid without cable end,Power circuit: screw clamp terminal 1 1…35 mm² - cable stiffness: solid without cable end,Power circuit: screw clamp terminal 2 1…25 mm² - cable stiffness: solid without cable end,Power circuit: screw clamp terminal 2 1…35 mm² - cable stiffness: solid without cable end
Tightening torque Control circuit: 1.2 N.m - on screw clamp terminal - with screwdriver flat Ø 6 mm,Control circuit: 1.2 N.m - on screw clamp terminal - with screwdriver Philips No 2,Power circuit: 5 N.m - on screw clamp terminal - with screwdriver flat Ø 6 mm,Power circuit: 5 N.m - on screw clamp terminal - with screwdriver flat Ø 8 mm,Control circuit: 1.2 N.m - on screw clamp terminal - with screwdriver pozidriv No 2
Auxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1, type mirror contact 1 NC conforming to IEC 60947-4-1
Minimum switching voltage 17 V for control circuit
Minimum switching current 5 mA for control circuit
Insulation resistance > 10 MOhm for control circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contacts,1.5 ms on energisation between NC and NO contacts
mounting support Rail,Plate

Environment

Standards IEC 60947-5-1,EN 60947-4-1,EN 60947-5-1,UL 508,IEC 60947-4-1,CSA C22.2 No 14
Product certifications CCC,BV,DNV,UL,GL,CSA,LROS (Lloyds register of shipping),RINA,GOST,UKCA
IP degree of protection IP2X conforming to IEC 60529,IP2X conforming to VDE 0106
Protective treatment TH (pollution degree 3) conforming to IEC 60068
Permissible ambient air temperature around the device -5…60 °C,-40…70 °C at Uc
Operating altitude 3000 m without derating
Fire resistance 850 °C conforming to IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Shocks contactor open (8 Gn for 11 ms) ,Shocks contactor closed (10 Gn for 11 ms) ,Vibrations contactor opened (2 Gn, 5...300 Hz) ,Vibrations contactor closed (3 Gn, 5...300 Hz)
Height 127 mm
Width 85 mm
Depth 130 mm
net weight 1.44 kg

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 15.2 cm
Package 1 Width 13.2 cm
Package 1 Length 10.8 cm
Package 1 Weight 1.472 kg
Unit Type of Package 2 S02
Number of Units in Package 2 5
Package 2 Height 15 cm
Package 2 Width 30 cm
Package 2 Length 40 cm
Package 2 Weight 7.815 kg

Contractual warranty

Warranty 18 months

Documentation

Product Datasheet

Instruction sheet

Catalogue

CAD

Environmental disclosure

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible