This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Schneider Electric

LC1D956FD

LC1D956FD Schneider Electric

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for LC1D956FD Schneider Electric

LC1D956FD Schneider Electric - contactor TeSys LC1-D - 3 poles - AC-3 440V 95 A - coil 48 V DC

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Available on back order
4 - 6 W.Weeks
£381.34 Exc. VAT
£457.61 Inc. VAT

Main

Range TeSys
range of product TeSys Deca
product or component type Contactor
Device short name LC1D
Contactor application Resistive load,Motor control
Utilisation category AC-3,AC-3e,AC-4,AC-1
Poles description 3P
[Ue] rated operational voltage Power circuit: <= 690 V AC 25...400 Hz
[Ie] rated operational current 95 A (at <60 °C) at <= 440 V AC-3 for power circuit,125 A (at <60 °C) at <= 1000 V AC-1 for power circuit,95 A (at <60 °C) at <= 440 V AC-3e for power circuit
[Uc] control circuit voltage 110 V DC

Complementary

Motor power kW 25 kW at 220...230 V AC 50 Hz (AC-3),45 kW at 380...400 V AC 50 Hz (AC-3),45 kW at 415...440 V AC 50 Hz (AC-3),55 kW at 500 V AC 50 Hz (AC-3),45 kW at 660...690 V AC 50 Hz (AC-3),15 kW at 400 V AC 50 Hz (AC-4),25 kW at 220...230 V AC 50 Hz (AC-3e),45 kW at 380...400 V AC 50 Hz (AC-3e),45 kW at 415...440 V AC 50 Hz (AC-3e),55 kW at 500 V AC 50 Hz (AC-3e),45 kW at 660...690 V AC 50 Hz (AC-3e),45 kW at 1000 V AC 50 Hz (AC-3e)
Motor power hp 7.5 hp at 115 V AC 60 Hz for 1 phase motors,15 hp at 230/240 V AC 60 Hz for 1 phase motors,25 hp at 200/208 V AC 60 Hz for 3 phases motors,30 hp at 230/240 V AC 60 Hz for 3 phases motors,60 hp at 460/480 V AC 60 Hz for 3 phases motors,60 hp at 575/600 V AC 60 Hz for 3 phases motors
compatibility code LC1D
Pole contact composition 3 NO
Protective cover With
[Ith] conventional free air thermal current 10 A (at 60 °C) for signalling circuit,125 A (at 60 °C) for power circuit
Irms rated making capacity 1100 A at 440 V AC for power circuit conforming to IEC 60947,140 A AC for signalling circuit conforming to IEC 60947-5-1,250 A DC for signalling circuit conforming to IEC 60947-5-1
Rated breaking capacity 1100 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 1100 A 40 °C - 1 s for power circuit,800 A 40 °C - 10 s for power circuit,400 A 40 °C - 1 min for power circuit,135 A 40 °C - 10 min for power circuit,140 A - 100 ms for signalling circuit,120 A - 500 ms for signalling circuit,100 A - 1 s for signalling circuit
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1,160 A gG at <= 690 V coordination type 2 for power circuit,200 A gG at <= 690 V coordination type 1 for power circuit
Average impedance 0.8 mOhm - Ith 125 A 50 Hz for power circuit
Power dissipation per pole 12.5 W AC-1,7.2 W AC-3,7.2 W AC-3e
[Ui] rated insulation voltage Power circuit: 1000 V conforming to IEC 60947-1,Signalling circuit: 690 V conforming to IEC 60947-1
Overvoltage category III
[Uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947
Safety reliability level B10d = 1.3 Mcycles contactor with nominal load conforming to EN/ISO 13849-1,B10d = 20 Mcycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability 10 Mcycles
Electrical durability 1.2 Mcycles 95 A AC-3,1.3 Mcycles 125 A AC-1,1.2 Mcycles 95 A AC-3e
Control circuit type DC standard
Coil technology Without built-in suppressor module
Control circuit voltage limits 0.1...0.3 Uc (-40…70 °C):drop-out DC,0.85...1.1 Uc (-40…55 °C):operational DC,1...1.1 Uc (55…70 °C):operational DC
Inrush power in W 22 W (at 20 °C)
Hold-in power consumption in W 22 W at 20 °C
Operating time 20...35 ms opening,95...130 ms closing
Time constant 75 ms
Maximum operating rate 3600 cyc/h 60 °C
Maximum operating rate 3600 cyc/h at 60 °C
Connections - terminals Control circuit: lugs - external diameter: 8 mm,Power circuit: lugs - external diameter: 17 mm,Power circuit: bars - busbar cross section: 3 x 16 mm
Tightening torque Control circuit: 1.2 N.m - on lugs - with screwdriver Philips No 2,Control circuit: 1.2 N.m - on lugs - with screwdriver flat Ø 6 mm,Power circuit: 12 N.m - with screwdriver flat Ø 8 mm,Power circuit: 12 N.m hexagonal screw head 10 mm,Control circuit: 1.2 N.m - on lugs - with screwdriver pozidriv No 2
Auxiliary contact composition 1 NO + 1 NC
Auxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1, type mirror contact 1 NC conforming to IEC 60947-4-1
Minimum switching voltage 17 V for signalling circuit
Minimum switching current 5 mA for signalling circuit
Insulation resistance > 10 MOhm for signalling circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contacts,1.5 ms on energisation between NC and NO contacts
mounting support Rail,Plate

Environment

Standards EN/IEC 60947-4-1,EN/IEC 60947-5-1,GB/T 14048.4
Product certifications IECEE CB Scheme,CCC,EAC,LROS (Lloyds register of shipping),RINA,BV,DNV-GL
IP degree of protection IP20 conforming to IEC 60529
Protective treatment TH (pollution degree 3) conforming to IEC 60068-2-30
Climatic withstand conforming to IACS E10 exposure to damp heat
Operating altitude 0...3000 m
Fire resistance 850 °C conforming to IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Shocks contactor opened (8 Gn for 11 ms) ,Shocks contactor closed (10 Gn for 11 ms) ,Vibrations contactor opened (2 Gn, 5...300 Hz) ,Vibrations contactor closed (3 Gn, 5...300 Hz)
Height 127 mm
Width 85 mm
Depth 186 mm
net weight 2.61 kg

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 10.0 cm
Package 1 Width 14.0 cm
Package 1 Length 21.0 cm
Package 1 Weight 2.544 kg

Contractual warranty

Warranty 18 months

Documentation

Product Datasheet

Instruction sheet

Catalogue

CAD

Environmental disclosure

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible