LC1DT60AMD Schneider Electric - TeSys D contactor - 4P(4 NO) - AC-1 - <= 440 V 60 A - 220 V DC standard coil

Extended Description for LC1DT60AMD Schneider Electric

LC1DT60AMD Schneider Electric - TeSys D contactor, 4 poles (4NO), for non-inductive load applications up to 60A/690V AC-1.,It provides a 220V DC coil with transient suppressor module, 1NO+1NC built-in auxiliary contacts (NC mirror certified), power connection by EverLink BTR screw connectors, control connection by screw clamp terminals.,For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability.,Compact (70mm width), DIN-rail mounting or screw fixing.,Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Available on back order
4 - 6 W.Weeks
£145.27 Exc. VAT
£174.32 Inc. VAT

Main

Range TeSys,TeSys Deca
range of product TeSys Deca
product or component type Contactor
Device short name LC1D
Contactor application Resistive load
Utilisation category AC-1
Poles description 4P
[Ue] rated operational voltage Power circuit: <= 690 V AC 25...400 Hz,Power circuit: <= 300 V DC
[Ie] rated operational current 60 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
[Uc] control circuit voltage 220 V DC

Complementary

compatibility code LC1D
Pole contact composition 4 NO
Protective cover With
[Ith] conventional free air thermal current 10 A (at 60 °C) for signalling circuit,60 A (at 60 °C) for power circuit
Irms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1,250 A DC for signalling circuit conforming to IEC 60947-5-1,800 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity 800 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 320 A 40 °C - 10 s for power circuit,720 A 40 °C - 1 s for power circuit,72 A 40 °C - 10 min for power circuit,165 A 40 °C - 1 min for power circuit,100 A - 1 s for signalling circuit,120 A - 500 ms for signalling circuit,140 A - 100 ms for signalling circuit
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1,80 A gG at <= 690 V coordination type 1 for power circuit,80 A gG at <= 690 V coordination type 2 for power circuit
Average impedance 1.6 mOhm - Ith 60 A 50 Hz for power circuit
Power dissipation per pole 5.8 W AC-1
[Ui] rated insulation voltage Power circuit: 600 V CSA certified,Power circuit: 600 V UL certified,Signalling circuit: 690 V conforming to IEC 60947-1,Signalling circuit: 600 V CSA certified,Signalling circuit: 600 V UL certified,Power circuit: 690 V conforming to IEC 60947-4-1
Overvoltage category III
Pollution degree 3
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1,B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability 10 Mcycles
Electrical durability 0.7 Mcycles 60 A AC-1 at Ue <= 440 V
Control circuit type DC standard
Coil technology Built-in bidirectional peak limiting diode suppressor
Control circuit voltage limits 0.1...0.3 Uc (-40…70 °C):drop-out DC,0.75...1.25 Uc (-40…60 °C):operational DC,1...1.25 Uc (60…70 °C):operational DC
Inrush power in W 19 W (at 20 °C)
Hold-in power consumption in W 7.4 W at 20 °C
Operating time 50 ±15 % ms closing,16...24 ms opening
Time constant 34 ms
Maximum operating rate 3600 cyc/h 60 °C
Maximum operating rate 3600 cyc/h at 60 °C
Connections - terminals Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end,Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end,Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end,Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end,Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end,Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end,Power circuit: screw clamp terminal 1 1…35 mm² - cable stiffness: flexible without cable end,Power circuit: screw clamp terminal 2 1…25 mm² - cable stiffness: flexible without cable end,Power circuit: screw clamp terminal 1 1…35 mm² - cable stiffness: flexible with cable end,Power circuit: screw clamp terminal 2 1…25 mm² - cable stiffness: flexible with cable end,Power circuit: screw clamp terminal 1 1…35 mm² - cable stiffness: solid without cable end,Power circuit: screw clamp terminal 2 1…25 mm² - cable stiffness: solid without cable end
Tightening torque Control circuit: 1.7 N.m - on EverLink BTR screw connectors - with screwdriver flat Ø 6 mm,Control circuit: 1.7 N.m - on EverLink BTR screw connectors - with screwdriver Philips No 2,Power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25…35 mm² hexagonal screw head 4 mm,Power circuit: 5 N.m - on EverLink BTR screw connectors - cable 1…25 mm² hexagonal screw head 4 mm,Control circuit: 1.7 N.m - on EverLink BTR screw connectors - with screwdriver pozidriv No 2,Power circuit: 2.5 N.m - on EverLink BTR screw connectors - with screwdriver pozidriv No 2
Auxiliary contact composition 1 NO + 1 NC
Auxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1, type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency 25...400 Hz
Minimum switching voltage 17 V for signalling circuit
Minimum switching current 5 mA for signalling circuit
Insulation resistance > 10 MOhm for signalling circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contact,1.5 ms on energisation between NC and NO contact
mounting support Rail,Plate

Environment

Standards CSA C22.2 No 14,EN 60947-4-1,EN 60947-5-1,IEC 60947-4-1,IEC 60947-5-1,UL 508,IEC 60335-1
Product certifications GL,DNV,BV,UL,RINA,CSA,CCC,GOST,LROS (Lloyds register of shipping)
IP degree of protection IP20 front face conforming to IEC 60529
Protective treatment TH conforming to IEC 60068-2-30
Climatic withstand conforming to IACS E10 exposure to damp heat, conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Permissible ambient air temperature around the device -40…60 °C,60…70 °C with derating
Operating altitude 0...3000 m
Fire resistance 850 °C conforming to IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Vibrations contactor open (2 Gn, 5...300 Hz) ,Vibrations contactor closed (4 Gn, 5...300 Hz) ,Shocks contactor closed (15 Gn for 11 ms) ,Shocks contactor open (10 Gn for 11 ms)
Height 122 mm
Width 70 mm
Depth 120 mm
net weight 1.165 kg

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 7.5 cm
Package 1 Width 14.0 cm
Package 1 Length 15.0 cm
Package 1 Weight 1.1 kg

Contractual warranty

Warranty 18 months

Documentation

Product Datasheet

Instruction sheet

Catalogue

CAD

Environmental disclosure

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible