Description for LC1F4002 Schneider Electric

LC1F4002 Schneider Electric - TeSys F contactor-2P(2 NO)-AC-1 <= 440V 500A with coil LX1/LX9 -48â¦1000V AC 40/400Hz, LX4 -48...440V DC, LXE -100...250V AC 50/60Hz or 100â¦380V DC

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Available on back order
4 - 6 W.Weeks
£915.88 Exc. VAT
£1,099.06 Inc. VAT

Main

Range TeSys
Product name TeSys F
product or component type Contactor
Device short name LC1F
Contactor application Resistive load
Utilisation category AC-1
Poles description 2P
power pole contact composition 2 NO
[Ue] rated operational voltage <= 1000 V AC 50/60 Hz,<= 460 V DC
[Ie] rated operational current 500 A (at <40 °C) at <= 440 V AC AC-1

Complementary

[Uc] control circuit voltage 48...1000 V AC 40...400 Hz with LX1/LX9 coil,48...440 V DC with LX4 coil,100...250 V AC 50/60 Hz with LXE coil,100...380 V DC with LXE coil
[Uimp] rated impulse withstand voltage 8 kV
Overvoltage category III
[Ith] conventional free air thermal current 500 A (at 40 °C)
Irms rated making capacity 4000 A AC conforming to IEC 60947-4-1
Rated breaking capacity 3200 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current 3600 A 40 °C - 10 s,2400 A 40 °C - 30 s,1700 A 40 °C - 1 min,1200 A 40 °C - 3 min,1000 A 40 °C - 10 min
Associated fuse rating 400 A aM at <= 440 V,500 A gG at <= 440 V
Average impedance 0.26 mOhm - Ith 500 A 50 Hz
[Ui] rated insulation voltage 1000 V conforming to IEC 60947-4-1,1500 V conforming to VDE 0110 group C
Power dissipation per pole 65 W AC-1
Control circuit voltage limits Operational: 0.85...1.1 Uc AC 40...400 Hz with LX1/LX9 coil,Drop-out: 0.3...0.5 Uc AC 40...400 Hz with LX1/LX9 coil,Operational: 0.85...1.1 Uc DC with LX4 coil,Drop-out: 0.2...0.35 Uc DC with LX4 coil,Operational: 85...275 V AC 50/60 Hz with LXE coil,Drop-out: 0...60 V AC 50/60 Hz with LXE coil,Operational: 85...418 V DC with LXE coil,Drop-out: 0...45 V DC with LXE coil
Heat dissipation 14 W,2.2…5.5 W
Operating time 40...75 ms closing for with LX1/LX9 coil,100...170 ms opening for with LX1/LX9 coil,50...60 ms closing for with LX4 coil,45...60 ms opening for with LX4 coil,40...80 ms closing for with LXE coil,6...54 ms opening for with LXE coil
mounting support Plate
Standards JIS C8201-4-1,IEC 60947-4-1,IEC 60947-1,EN 60947-4-1,EN 60947-1
Product certifications CB,ABS,DNV,RMRoS,LROS (Lloyds register of shipping),BV,RINA,UL,CSA,UKCA
Connections - terminals Power circuit: bar 2 cable(s) - busbar cross section: 30 x 5 mm,Power circuit: lugs-ring terminals 2 cable(s) 150 mm²,Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end,Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible with cable end,Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end,Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²solid without cable end,Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²,Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²,Control circuit: screw clamp terminals 1.0 cable(s) 0.2…2.5 mm²flexible without cable end,Control circuit: screw clamp terminals 1.0 cable(s) 0.25…2.5 mm²flexible with cable end,Control circuit: screw clamp terminals 1.0 cable(s) 0.2…2.5 mm²solid without cable end
Tightening torque Power circuit: 35 N.m,Control circuit: 1.2 N.m,Control circuit: 0.6 N.m
Mechanical durability 10 Mcycles
Inrush power in VA 1000…1150 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil,920…1140 VA (at 20 °C)with LX4 coil,360…470 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil,410…450 VA (at 20 °C)with LXE coil
Hold-in power consumption in VA 12…18 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil,4…7.5 VA (at 20 °C)with LX4 coil,4.5…7.0 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil,2.5…4.0 VA (at 20 °C)with LXE coil
Maximum operating rate 2400 cyc/h 55 °C
compatibility code LC1F

Environment

IP degree of protection IP20 front face with shrouds conforming to IEC 60529,IP20 front face with shrouds conforming to VDE 0106
Protective treatment TH
Ambient air temperature for operation -5…55 °C
Ambient air temperature for storage -60…80 °C
Permissible ambient air temperature around the device -40…70 °C
Operating altitude 3000 m without derating
Mechanical robustness Vibrations contactor open: 1.5 Gn, 5...300 Hz,Vibrations contactor closed: 5 Gn, 5...300 Hz,Shocks contactor open: 6 Gn for 1/2 sine wave (11 ms),Shocks contactor closed: 15 Gn for 1/2 sine wave (11 ms)
Height 206 mm
Width 213 mm
Depth 219 mm
net weight 8 kg

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 24.0 cm
Package 1 Width 25.0 cm
Package 1 Length 31.0 cm
Package 1 Weight 7.2 kg
Unit Type of Package 2 P06
Number of Units in Package 2 10
Package 2 Height 77.0 cm
Package 2 Width 80.0 cm
Package 2 Length 60.0 cm
Package 2 Weight 81.5 kg

Contractual warranty

Warranty 18 months

Documentation

Product Datasheet

Instruction sheet

Catalogue

CAD

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible