This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Schneider Electric

LC1F5004

LC1F5004 Schneider Electric

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for LC1F5004 Schneider Electric

LC1F5004 Schneider Electric - TeSys F contactor - 4P(4 NO)-AC-1 <= 440V 700A with coil LX1/ LX9 - 48â¦1000V AC 40/400Hz, LX4 - 48...440V DC

Extended Description for LC1F5004 Schneider Electric

LC1F5004 Schneider Electric - TeSys F contactor, 4 poles (4NO), 700A/1000V AC-1, for non-inductive load applications.,Contactor with no coil to allow a later selection and installation (coil to be ordered separately), it provides bolt terminals for bars or cables with lugs.,For high operating rates until 2400 cycles/hour and environments until 55°C, it procures high reliability and durability.,It makes installation and maintenance easy thanks to a drawer for insertion of the selected coil and a large choice of add-on blocks and accessories (to be ordered separately).,Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Available on back order
4 - 6 W.Weeks
£1,613.55 Exc. VAT
£1,936.26 Inc. VAT

Main

Range TeSys
Product name TeSys F
product or component type Contactor
Device short name LC1F
Contactor application Resistive load
Utilisation category AC-1
Poles description 4P
power pole contact composition 4 NO
[Ue] rated operational voltage <= 1000 V AC 50/60 Hz,<= 460 V DC
[Ie] rated operational current 700 A (at <40 °C) at <= 440 V AC AC-1

Complementary

[Uc] control circuit voltage 48...1000 V AC 40...400 Hz with LX1/LX9 coil,48...440 V DC with LX4 coil
[Uimp] rated impulse withstand voltage 8 kV
Overvoltage category III
[Ith] conventional free air thermal current 700 A (at 40 °C)
Irms rated making capacity 5000 A AC conforming to IEC 60947-4-1
Rated breaking capacity 4000 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current 4200 A 40 °C - 10 s,3200 A 40 °C - 30 s,2400 A 40 °C - 1 min,1500 A 40 °C - 3 min,1200 A 40 °C - 10 min
Associated fuse rating 500 A aM at <= 440 V,800 A gG at <= 440 V
Average impedance 0.18 mOhm - Ith 700 A 50 Hz
[Ui] rated insulation voltage 1000 V conforming to IEC 60947-4-1,1500 V conforming to VDE 0110 group C
Power dissipation per pole 88 W AC-1
Control circuit voltage limits Operational: 0.85...1.1 Uc AC 40...400 Hz with LX1/LX9 coil,Drop-out: 0.3...0.5 Uc AC 40...400 Hz with LX1/LX9 coil,Operational: 0.85...1.1 Uc DC with LX4 coil,Drop-out: 0.2...0.35 Uc DC with LX4 coil
Heat dissipation 18 W
Operating time 40...75 ms closing for with LX1/LX9 coil,100...170 ms opening for with LX1/LX9 coil,50...60 ms closing for with LX4 coil,45...60 ms opening for with LX4 coil
mounting support Plate
Standards JIS C8201-4-1,EN 60947-1,IEC 60947-1,EN 60947-4-1,IEC 60947-4-1
Product certifications CSA,LROS (Lloyds register of shipping),DNV,BV,ABS,CB,RMRoS,RINA,UL,UKCA
Connections - terminals Power circuit: lugs-ring terminals 2 cable(s) 240 mm²,Power circuit: bar 2 cable(s) - busbar cross section: 40 x 5 mm,Power circuit: bolted connection,Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end,Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible with cable end,Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end,Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²solid without cable end,Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²,Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²
Tightening torque Power circuit: 35 N.m,Control circuit: 1.2 N.m
Mechanical durability 10 Mcycles
Inrush power in VA 1050…1150 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil,990…1220 VA (at 20 °C)with LX4 coil
Hold-in power consumption in VA 16…20 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil,4.54…8 VA (at 20 °C)with LX4 coil
Maximum operating rate 2400 cyc/h 55 °C
compatibility code LC1F

Environment

IP degree of protection IP20 front face with shrouds conforming to IEC 60529,IP20 front face with shrouds conforming to VDE 0106
Protective treatment TH
Ambient air temperature for operation -5…55 °C
Ambient air temperature for storage -60…80 °C
Permissible ambient air temperature around the device -40…70 °C
Operating altitude 3000 m without derating
Mechanical robustness Vibrations contactor open: 2 Gn, 5...300 Hz,Vibrations contactor closed: 4 Gn, 5...300 Hz,Shocks contactor open: 9 Gn for 1/2 sine wave (11 ms),Shocks contactor closed: 15 Gn for 1/2 sine wave (11 ms)
Height 238 mm
Width 288 mm
Depth 232 mm
net weight 9.75 kg

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 27.500 cm
Package 1 Width 29.500 cm
Package 1 Length 34.500 cm
Package 1 Weight 12.558 kg
Unit Type of Package 2 P06
Number of Units in Package 2 8
Package 2 Height 75.000 cm
Package 2 Width 60.000 cm
Package 2 Length 80.000 cm
Package 2 Weight 111.604 kg

Contractual warranty

Warranty 18 months

Documentation

Product Datasheet

Instruction sheet

Catalogue

CAD

Environmental disclosure

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible