This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Schneider Electric

LC1G330EHEN

LC1G330EHEN Schneider Electric

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for LC1G330EHEN Schneider Electric

LC1G330EHEN Schneider Electric - High power contactor, TeSys Giga, 3 pole (3NO), AC-3 <=440V 330A, standard version, 48â¦130V wide band AC/DC coil

Extended Description for LC1G330EHEN Schneider Electric

LC1G330EHEN Schneider Electric - TeSys Giga high power contactor, 3 poles (3 NO) for category AC-3 applications up to 330A 200kW@440V.,It provides a 48-130V AC/DC wide band low consumption electronic coil and embedded highly reliability 1NO+1NC auxiliary contact block (17V 1mA).,Designed for demanding applications with maximum operating rates up to 600 cycles per hour and environments until 60°C.,It procures high reliability and durability with 5 Mcycles mechanical durability.,Local Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators.,It is possibility to replace switching module (main contacts), enhancement contactor life.,Contactor can be fixed in all quadrants, maintenance without removing cables/busbars, and OLR could be directly mounted below contactor.,To be used with power connection by bolted connection and control connections by spring terminals, accessible from front for easy and quick replacement.,It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106.,It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, No derating up to 3000m altitude.,The dimension is 290mm x 140mm x 209mm (H x W x D), compact size enables panel space savings.,Multi standards certified(CE,CB,CCC,cULus,EAC,KC,RCM,Marine) and Green Premium compliant (RoHs/Reach).,Unique QR code provides quick access to complete product data.

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Available on back order
4 - 6 W.Weeks
£635.06 Exc. VAT
£762.08 Inc. VAT

Main

Range TeSys
range of product TeSys Giga
product or component type Contactor
Device short name LC1G
Contactor application Power switching,Motor control
Utilisation category AC-1,AC-3,AC-3e,AC-4,AC-5a,AC-5b,AC-6a,AC-6b,AC-8b,AC-8a,DC-1,DC-3,DC-5
Poles description 3P
[Ue] rated operational voltage <= 1000 V AC 50/60 Hz,<= 460 V DC
[Ie] rated operational current 440 A (at <40 °C) at <= 1000 V AC-1,330 A (at <60 °C) at <= 440 V AC-3
[Uc] control circuit voltage 48...130 V AC 50/60 Hz,48...130 V DC
Control circuit voltage limits Operational: 0.8 Uc Min...1.1 Uc Max (at <60 °C),Drop-out: 0.1 Uc Max...0.45 Uc Min (at <60 °C)

Complementary

[Uimp] rated impulse withstand voltage 8 kV
Overvoltage category III
[Ith] conventional free air thermal current 440 A (at 40 °C)
Rated breaking capacity 2940 A at 440 V
[Icw] rated short-time withstand current 2.65 kA - 10 s,1.8 kA - 30 s,1.3 kA - 1 min,0.9 kA - 3 min,0.75 kA - 10 min
Associated fuse rating 400 A aM at <= 440 V for motor,250 A aM at <= 690 V for motor,500 A gG at <= 690 V
Average impedance 0.000144 Ohm
[Ui] rated insulation voltage 1000 V
Power dissipation per pole 30 W AC-1 - Ith 440 A,16 W AC-3 - Ith 330 A
compatibility code LC1G
Pole contact composition 3 NO
Auxiliary contact composition 1 NO + 1 NC
Motor power kW 90 kW at 230 V AC 50/60 Hz (AC-3e),160 kW at 400 V AC 50/60 Hz (AC-3e),160 kW at 415 V AC 50/60 Hz (AC-3e),185 kW at 440 V AC 50/60 Hz (AC-3e),200 kW at 500 V AC 50/60 Hz (AC-3e),220 kW at 690 V AC 50/60 Hz (AC-3e),185 kW at 1000 V AC 50/60 Hz (AC-3e),90 kW at 230 V AC 50/60 Hz (AC-3),160 kW at 400 V AC 50/60 Hz (AC-3),160 kW at 415 V AC 50/60 Hz (AC-3),200 kW at 440 V AC 50/60 Hz (AC-3),200 kW at 500 V AC 50/60 Hz (AC-3),220 kW at 690 V AC 50/60 Hz (AC-3),185 kW at 1000 V AC 50/60 Hz (AC-3),90 kW at 230 V AC 50/60 Hz (AC-4),160 kW at 400 V AC 50/60 Hz (AC-4),160 kW at 415 V AC 50/60 Hz (AC-4),185 kW at 440 V AC 50/60 Hz (AC-4),200 kW at 500 V AC 50/60 Hz (AC-4),220 kW at 690 V AC 50/60 Hz (AC-4),185 kW at 1000 V AC 50/60 Hz (AC-4)
Motor power hp 100 hp at 200/208 V 60 Hz,125 hp at 230/240 V 60 Hz,250 hp at 460/480 V 60 Hz,300 hp at 575/600 V 60 Hz
Irms rated making capacity 3830 A at 440 V
Coil technology Built-in bidirectional peak limiting
Safety reliability level B10d = 400000 cycles contactor with nominal load conforming to EN/ISO 13849-1,B10d = 3000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability 8 Mcycles
inrush power in VA (50/60 Hz, AC) 780 VA
inrush power in W (DC) 695 W
hold-in power consumption in VA (50/60 Hz, AC) 17.6 VA
hold-in power consumption in W (DC) 7.8 W
Operating time 40...70 ms closing,15...50 ms opening
Maximum operating rate 600 cyc/h AC-3,600 cyc/h AC-3e,300 cyc/h AC-1,150 cyc/h AC-4
Connections - terminals Power circuit: bar 2 - busbar cross section: 32 x 10 mm,Power circuit: lugs-ring terminals 1 185 mm²,Power circuit: bolted connection,Control circuit: push-in 1 0.2…2.5 mm² - cable stiffness: solid stranded without cable end,Control circuit: push-in 1 0.25…2.5 mm² - cable stiffness: flexible with cable end,Control circuit: push-in 2 0.5…1.0 mm² with cable end,Control circuit: push-in 0.75…2.5 mm² - cable stiffness: solid stranded without cable end,Control circuit: push-in 0.75…2.5 mm² - cable stiffness: flexible with cable end
Connection pitch 45 mm
mounting support Plate
Standards EN/IEC 60947-4-1,EN/IEC 60947-5-1,UL 60947-4-1,CSA C22.2 No 60947-4-1,JIS C8201-4-1,JIS C8201-5-1,IEC 60335-1:Clause 30.2,IEC 60335-2-40:Annex JJ,UL 60335-1,UL 60335-2-40:Annex JJ
Product certifications CB Scheme,CCC,cULus,EAC,CE,UKCA,EU-RO-MR by DNV-GL
Tightening torque 35 N.m
Height 225 mm
Width 140 mm
Depth 226 mm
net weight 7.5 kg

Environment

IP degree of protection IP2X front face with shrouds conforming to IEC 60529,IP2X front face with shrouds conforming to VDE 0106
Ambient air temperature for operation -25…60 °C
Ambient air temperature for storage -60…80 °C
Mechanical robustness Vibrations 5…300 Hz 2 gn contactor open,Vibrations 5…300 Hz 4 gn contactor closed,Shocks 10 gn 11 ms contactor open,Shocks 15 gn 11 ms contactor closed
Colour Dark grey
Protective treatment TH
Permissible ambient air temperature around the device -40…70 °C at Uc

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 31.000 cm
Package 1 Width 22.500 cm
Package 1 Length 31.500 cm
Package 1 Weight 7.481 kg
Unit Type of Package 2 S06
Number of Units in Package 2 4
Package 2 Height 105.000 cm
Package 2 Width 60.000 cm
Package 2 Length 80.000 cm
Package 2 Weight 39.924 kg

Contractual warranty

Warranty 18 months

Documentation

Product Datasheet

User guide

Instruction sheet

Catalogue

CAD

Environmental disclosure

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible