This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Schneider Electric

LC2D115004M7

LC2D115004M7 Schneider Electric

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for LC2D115004M7 Schneider Electric

LC2D115004M7 Schneider Electric - TeSys D changeover contactor - 4P(4 NO) - AC-1 - <= 440 V 200 A - 220 V AC coil

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Available on back order
4 - 6 W.Weeks
£1,472.59 Exc. VAT
£1,767.11 Inc. VAT

Main

Range TeSys
Product name TeSys Deca
product or component type Changeover contactor
Device short name LC2D
Contactor application Resistive load
Utilisation category AC-1,AC-3,AC-3e,AC-4
Device presentation Preassembled with reversing power busbar
Poles description 4P
power pole contact composition 4 NO
[Ue] rated operational voltage Power circuit: <= 1000 V AC 25...400 Hz,Power circuit: <= 460 V DC
[Ie] rated operational current 200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
Control circuit type AC at 50/60 Hz
[Uc] control circuit voltage 220 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947
Overvoltage category III
[Ith] conventional free air thermal current 200 A (at 60 °C) for power circuit
Irms rated making capacity 1260 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity 1260 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 250 A 40 °C - 10 min for power circuit,550 A 40 °C - 1 min for power circuit,950 A 40 °C - 10 s for power circuit,1100 A 40 °C - 1 s for power circuit
Associated fuse rating 250 A gG at <= 690 V coordination type 1 for power circuit,200 A gG at <= 690 V coordination type 2 for power circuit
Average impedance 0.6 mOhm - Ith 200 A 50 Hz for power circuit
[Ui] rated insulation voltage Power circuit: 600 V CSA certified,Power circuit: 600 V UL certified,Power circuit: 1000 V conforming to IEC 60947-4-1
Electrical durability 0.5 Mcycles 250 A AC-1 at Ue <= 690 V
Power dissipation per pole 24 W AC-1
Front cover With
Interlocking type Mechanical
mounting support Rail,Plate
Standards CSA C22.2 No 14,EN 60947-4-1,EN 60947-5-1,IEC 60947-4-1,IEC 60947-5-1,UL 508
Product certifications UL,CSA,CCC,EAC,UKCA,CB,DNV-GL,RINA,BV,LROS (Lloyds register of shipping)
Connections - terminals Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end,Control circuit: screw clamp terminals 1 cable(s) 1…2.5 mm²flexible without cable end,Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible without cable end,Control circuit: screw clamp terminals 1 cable(s) 1…2.5 mm²flexible with cable end,Control circuit: screw clamp terminals 1 cable(s) 1…2.5 mm²solid without cable end,Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²solid without cable end,Power circuit: connector 1 cable(s) 10…120 mm²flexible without cable end,Power circuit: connector 2 cable(s) 10…50 mm²flexible without cable end,Power circuit: connector 1 cable(s) 10…120 mm²flexible with cable end,Power circuit: connector 2 cable(s) 10…50 mm²flexible with cable end,Power circuit: connector 1 cable(s) 10…120 mm²solid without cable end,Power circuit: connector 2 cable(s) 10…50 mm²solid without cable end
Tightening torque Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm,Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2,Power circuit: 12 N.m - on connector hexagonal screw head 4 mm,Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
Operating time 20...50 ms closing,6...20 ms opening
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1,B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability 8000000 cycles
Maximum operating rate 1200 cyc/h 60 °C

Complementary

Coil technology Built-in bidirectional peak limiting diode suppressor
Control circuit voltage limits 0.3...0.5 Uc (-40…55 °C):drop-out AC 50 Hz,0.8...1.15 Uc (-40…55 °C):operational AC 50 Hz
Inrush power in VA 280…350 VA 60 Hz cos phi 0.9 (at 20 °C) ,280…350 VA 50 Hz cos phi 0.9 (at 20 °C)
Hold-in power consumption in VA 2…18 VA (at 20 °C) cos phi 0.3 60 Hz,2…18 VA (at 20 °C) cos phi 0.3 50 Hz
Heat dissipation 3…8 W at 50/60 Hz

Environment

IP degree of protection IP20 front face conforming to IEC 60529
Climatic withstand conforming to IACS E10
Protective treatment TH conforming to IEC 60068-2-30
Pollution degree 3
Ambient air temperature for operation -40…60 °C,60…70 °C with derating
Ambient air temperature for storage -60…80 °C
Operating altitude 0...3000 m
Fire resistance 850 °C conforming to IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Vibrations contactor open: 2 Gn, 5...300 Hz,Vibrations contactor closed: 4 Gn, 5...300 Hz,Shocks contactor closed: 15 Gn for 11 ms,Shocks contactor open: 6 Gn for 11 ms
Height 158 mm
Width 334 mm
Depth 148 mm
net weight 7.4 kg

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 22.5 cm
Package 1 Width 32.0 cm
Package 1 Length 43.5 cm
Package 1 Weight 7.4 kg

Contractual warranty

Warranty 18 months

Documentation

Product Datasheet

Instruction sheet

Catalogue

CAD

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible