Description for LC2D12BLV Schneider Electric

LC2D12BLV Schneider Electric - TeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

Extended Description for LC2D12BLV Schneider Electric

LC2D12BLV Schneider Electric - TeSys D reversing contactor, 3 poles (3NO), for motor control applications up to 12A/690V AC-3 (5.5kW@400V).,It provides low consumption 24V DC coils with transient suppressor module, 2NO+2NC built-in auxiliary contacts (NC mirror contacts), connection by screw clamp terminals.,For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability.,Compact (90mm width), DIN-rail mounting or screw fixing.,With pre-wired reversing power connections, mechanical interlock (without electrical interlocking).,Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Available on back order
4 - 6 W.Weeks
£64.46 Exc. VAT
£77.35 Inc. VAT

Main

Range TeSys,TeSys Deca
Product name TeSys D,TeSys Deca
product or component type Reversing contactor
Device short name LC2D
Contactor application Resistive load,Motor control
Utilisation category AC-3,AC-1,AC-3e
Device presentation Preassembled with reversing power busbar
Poles description 3P
power pole contact composition 3 NO
[Ue] rated operational voltage Power circuit: <= 690 V AC 25...400 Hz,Power circuit: <= 300 V DC
[Ie] rated operational current 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit,12 A (at <60 °C) at <= 440 V AC AC-3 for power circuit,12 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
Motor power kW 3 kW at 220...230 V AC 50 Hz,5.5 kW at 380...400 V AC 50 Hz,5.5 kW at 415 V AC 50 Hz,5.5 kW at 440 V AC 50 Hz,7.5 kW at 500 V AC 50 Hz,7.5 kW at 660...690 V AC 50 Hz
motor power HP (UL / CSA) 1 hp at 115 V AC 60 Hz for 1 phase motors,2 hp at 230/240 V AC 60 Hz for 1 phase motors,3 hp at 200/208 V AC 60 Hz for 3 phases motors,3 hp at 230/240 V AC 60 Hz for 3 phases motors,7.5 hp at 460/480 V AC 60 Hz for 3 phases motors,10 hp at 575/600 V AC 60 Hz for 3 phases motors
Control circuit type DC low consumption
[Uc] control circuit voltage 24 V DC
Auxiliary contact composition 1 NO + 1 NC
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
Overvoltage category III
[Ith] conventional free air thermal current 10 A (at 60 °C) for signalling circuit,25 A (at 60 °C) for power circuit
Irms rated making capacity 250 A at 440 V for power circuit conforming to IEC 60947,140 A AC for signalling circuit conforming to IEC 60947-5-1,250 A DC for signalling circuit conforming to IEC 60947-5-1
Rated breaking capacity 250 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 30 A 40 °C - 10 min for power circuit,61 A 40 °C - 1 min for power circuit,105 A 40 °C - 10 s for power circuit,210 A 40 °C - 1 s for power circuit,100 A - 1 s for signalling circuit,120 A - 500 ms for signalling circuit,140 A - 100 ms for signalling circuit
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1,40 A gG at <= 690 V coordination type 1 for power circuit,25 A gG at <= 690 V coordination type 2 for power circuit
Average impedance 2.5 mOhm - Ith 25 A 50 Hz for power circuit
[Ui] rated insulation voltage Power circuit: 690 V conforming to IEC 60947-4-1,Power circuit: 600 V CSA certified,Power circuit: 600 V UL certified,Signalling circuit: 690 V conforming to IEC 60947-1,Signalling circuit: 600 V CSA certified,Signalling circuit: 600 V UL certified
Electrical durability 2 Mcycles 12 A AC-3 at Ue <= 440 V,0.8 Mcycles 25 A AC-1 at Ue <= 440 V,2 Mcycles 12 A AC-3e at Ue <= 440 V
Power dissipation per pole 1.56 W AC-1,0.36 W AC-3,0.36 W AC-3e
Front cover With
Interlocking type Electrical and mechanical
mounting support Rail,Plate
Standards CSA C22.2 No 14,EN 60947-4-1,EN 60947-5-1,IEC 60947-4-1,IEC 60947-5-1,UL 508,IEC 60335-1
Product certifications DNV,CSA,CCC,UL,GL,LROS (Lloyds register of shipping),BV,RINA,GOST,UKCA
Connections - terminals Power circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end,Power circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end,Power circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end,Power circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end,Power circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid,Power circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid,Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end,Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end,Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end,Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end,Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid,Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid
Tightening torque Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm,Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2,Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm,Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2,Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2,Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
Operating time 65.45...88.55 ms closing,20...30 ms opening
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1,B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability 30 Mcycles
Maximum operating rate 3600 cyc/h 60 °C

Complementary

Coil technology Built-in bidirectional peak limiting diode suppressor
Control circuit voltage limits 0.1...0.3 Uc (-40…70 °C):drop-out DC,0.8...1.25 Uc (-40…60 °C):operational DC,1...1.25 Uc (60…70 °C):operational DC
Time constant 40 ms
Inrush power in W 2.4 W (at 20 °C)
Hold-in power consumption in W 2.4 W at 20 °C
Auxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1, type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency 25...400 Hz
Minimum switching current 5 mA for signalling circuit
Minimum switching voltage 17 V for signalling circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contact,1.5 ms on energisation between NC and NO contact
Insulation resistance > 10 MOhm for signalling circuit

Environment

IP degree of protection IP20 front face conforming to IEC 60529
Climatic withstand conforming to IACS E10, conforming to IEC 60947-1 Annex Q category D
Protective treatment TH conforming to IEC 60068-2-30
Pollution degree 3
Ambient air temperature for operation -40…60 °C,60…70 °C with derating
Ambient air temperature for storage -60…80 °C
Operating altitude 0...3000 m
Fire resistance 850 °C conforming to IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Vibrations contactor open: 2 Gn, 5...300 Hz,Vibrations contactor closed: 4 Gn, 5...300 Hz,Shocks contactor open: 10 Gn for 11 ms,Shocks contactor closed: 15 Gn for 11 ms
Height 77 mm
Width 90 mm
Depth 95 mm
net weight 1.027 kg

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 9.5 cm
Package 1 Width 14.0 cm
Package 1 Length 11.3 cm
Package 1 Weight 1.158 kg
Unit Type of Package 2 S02
Number of Units in Package 2 6
Package 2 Height 15.0 cm
Package 2 Width 30.0 cm
Package 2 Length 40.0 cm
Package 2 Weight 7.294 kg

Contractual warranty

Warranty 18 months

Documentation

Product Datasheet

Instruction sheet

CAD

Environmental disclosure