Description for LC2D150B7 Schneider Electric

LC2D150B7 Schneider Electric - TeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC coil

Extended Description for LC2D150B7 Schneider Electric

LC2D150B7 Schneider Electric - TeSys Deca reversing contactor, 3 poles (3NO), for motor control applications up to 150A/1000V AC-3 (75kW@400V).,It provides 24V 50/60Hz AC coils with transient suppressor module, 2NO+2NC built-in auxiliary contacts (NC mirrror certified), power connection by screw connectors 2 inputs, control by screw clamp terminals.,For operating rates until 1200 cycles/hour and environments until 60°C, it procures high reliability and durability.,Compact (266mm width), mounting on 2 DIN-rails or screw fixing.,With pre-wired reversing power connections, mechanical and electrical interlock.,Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Available on back order
4 - 6 W.Weeks
£828.75 Exc. VAT
£994.50 Inc. VAT

Main

Range TeSys
Product name TeSys Deca
product or component type Reversing contactor
Device short name LC2D
Contactor application Motor control,Resistive load
Utilisation category AC-3,AC-1,AC-3e
Device presentation Preassembled with reversing power busbar
Poles description 3P
power pole contact composition 3 NO
[Ue] rated operational voltage Power circuit: <= 1000 V AC 25...400 Hz,Power circuit: <= 300 V DC
[Ie] rated operational current 200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit,150 A (at <60 °C) at <= 440 V AC AC-3 for power circuit,150 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
Motor power kW 40 kW at 220...230 V AC 50 Hz,75 kW at 380...400 V AC 50 Hz,80 kW at 415...440 V AC 50 Hz,90 kW at 500 V AC 50 Hz,100 kW at 660...690 V AC 50 Hz,75 kW at 1000 V AC 50 Hz
motor power HP (UL / CSA) 40 hp at 200/208 V AC 60 Hz for 3 phases motors,50 hp at 230/240 V AC 60 Hz for 3 phases motors,100 hp at 460/480 V AC 60 Hz for 3 phases motors,125 hp at 575/600 V AC 60 Hz for 3 phases motors
Control circuit type AC at 50/60 Hz
[Uc] control circuit voltage 24 V AC 50/60 Hz
Auxiliary contact composition 1 NO + 1 NC
[Uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947
Overvoltage category III
[Ith] conventional free air thermal current 200 A (at 60 °C) for power circuit
Irms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1,250 A DC for signalling circuit conforming to IEC 60947-5-1,1660 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity 1400 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 250 A 40 °C - 10 min for power circuit,580 A 40 °C - 1 min for power circuit,1200 A 40 °C - 10 s for power circuit,1400 A 40 °C - 1 s for power circuit,100 A - 1 s for signalling circuit,120 A - 500 ms for signalling circuit,140 A - 100 ms for signalling circuit
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1,315 A gG at <= 690 V coordination type 1 for power circuit,250 A gG at <= 690 V coordination type 2 for power circuit
Average impedance 0.6 mOhm - Ith 200 A 50 Hz for power circuit
[Ui] rated insulation voltage Power circuit: 600 V CSA certified,Power circuit: 600 V UL certified,Signalling circuit: 690 V conforming to IEC 60947-1,Signalling circuit: 600 V CSA certified,Signalling circuit: 600 V UL certified,Power circuit: 1000 V conforming to IEC 60947-4-1
Electrical durability 0.85 Mcycles 150 A AC-3 at Ue <= 440 V,1 Mcycles 200 A AC-1 at Ue <= 440 V,0.85 Mcycles 150 A AC-3e at Ue <= 440 V
Power dissipation per pole 24 W AC-1,13.5 W AC-3,13.5 W AC-3e
Front cover With
Interlocking type Mechanical,Electrical
mounting support Plate,Rail
Standards CSA C22.2 No 14,EN 60947-4-1,EN 60947-5-1,IEC 60947-4-1,IEC 60947-5-1,UL 508
Product certifications BV,CCC,CSA,DNV,GL,RINA,UL,EAC,UKCA
Connections - terminals Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end,Control circuit: screw clamp terminals 1 cable(s) 1…2.5 mm²flexible without cable end,Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible without cable end,Control circuit: screw clamp terminals 1 cable(s) 1…2.5 mm²flexible with cable end,Control circuit: screw clamp terminals 1 cable(s) 1…2.5 mm²solid without cable end,Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²solid without cable end,Power circuit: connector 1 cable(s) 10…120 mm²flexible without cable end,Power circuit: connector 2 cable(s) 10…50 mm²flexible without cable end,Power circuit: connector 1 cable(s) 10…120 mm²flexible with cable end,Power circuit: connector 2 cable(s) 10…50 mm²flexible with cable end,Power circuit: connector 1 cable(s) 10…120 mm²solid without cable end,Power circuit: connector 2 cable(s) 10…50 mm²solid without cable end
Tightening torque Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm,Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2,Power circuit: 12 N.m - on connector hexagonal screw head 4 mm,Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
Operating time 20...35 ms closing,40...75 ms opening
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1,B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability 8000000 cycles
Maximum operating rate 1200 cyc/h 60 °C

Complementary

Coil technology Built-in bidirectional peak limiting diode suppressor
Control circuit voltage limits 0.3...0.5 Uc (55 °C):drop-out AC 50/60 Hz,0.8...1.15 Uc (55 °C):operational AC 50/60 Hz
Inrush power in VA 280…350 VA 60 Hz cos phi 0.9 (at 20 °C) ,280…350 VA 50 Hz cos phi 0.9 (at 20 °C)
Hold-in power consumption in VA 2…18 VA (at 20 °C) cos phi 0.9 60 Hz,2…18 VA (at 20 °C) cos phi 0.9 50 Hz
Heat dissipation 3…4.5 W at 50/60 Hz
Auxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1, type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency 25...400 Hz
Minimum switching current 5 mA for signalling circuit
Minimum switching voltage 17 V for signalling circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contact,1.5 ms on energisation between NC and NO contact
Insulation resistance > 10 MOhm for signalling circuit

Environment

IP degree of protection IP20 front face conforming to IEC 60529
Climatic withstand conforming to IACS E10
Protective treatment TH conforming to IEC 60068-2-30
Pollution degree 3
Ambient air temperature for operation -40…60 °C,60…70 °C with derating
Ambient air temperature for storage -60…80 °C
Operating altitude 0...3000 m
Fire resistance 850 °C conforming to IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Vibrations contactor open: 2 Gn, 5...300 Hz,Vibrations contactor closed: 4 Gn, 5...300 Hz,Shocks contactor closed: 15 Gn for 11 ms,Shocks contactor open: 6 Gn for 11 ms
Height 158 mm
Width 266 mm
Depth 148 mm
net weight 6.4 kg

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 23.0 cm
Package 1 Width 31.5 cm
Package 1 Length 37.0 cm
Package 1 Weight 6.5 kg

Contractual warranty

Warranty 18 months