This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Schneider Electric

LC2K1610G7

LC2K1610G7 Schneider Electric

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for LC2K1610G7 Schneider Electric

LC2K1610G7 Schneider Electric - TeSys K reversing contactor - 3P - AC-3 <= 440 V 16 A - 1 NO - 120 V AC coil

Free Delivery to UK Mainland on orders over £25

Main

Range TeSys
Product name TeSys K
product or component type Reversing contactor
Device short name LC2K
device application Control
Contactor application Motor control
Utilisation category AC-3,AC-4
Device presentation Preassembled with reversing power busbar
Poles description 3P
power pole contact composition 3 NO
[Ue] rated operational voltage Power circuit: 690 V AC 50/60 Hz,Signalling circuit: <= 690 V AC 50/60 Hz
[Ie] rated operational current 16 A at <= 440 V AC AC-3 for power circuit
Motor power kW 4 kW at 480 V AC 50/60 Hz,4 kW at 500...600 V AC 50/60 Hz,4 kW at 660...690 V AC 50/60 Hz,5.5 kW at 440 V AC 50/60 Hz,4 kW at 220...230 V AC 50/60 Hz,7.5 kW at 380...415 V AC 50/60 Hz
Control circuit type AC at 50/60 Hz
[Uc] control circuit voltage 120 V AC 50/60 Hz
Auxiliary contact composition 1 NO
[Uimp] rated impulse withstand voltage 8 kV
Overvoltage category III
[Ith] conventional free air thermal current 20 A (at 50 °C) for power circuit,10 A (at 50 °C) for signalling circuit
Irms rated making capacity 160 A at 690 V AC for power circuit conforming to NF C 63-110,160 A at 690 V AC for power circuit conforming to IEC 60947,110 A AC for signalling circuit conforming to IEC 60947
Rated breaking capacity 110 A at 440 V conforming to IEC 60947,80 A at 500 V conforming to IEC 60947,70 A at 660...690 V conforming to IEC 60947
[Icw] rated short-time withstand current 115 A 50 °C - 1 s for power circuit,105 A 50 °C - 5 s for power circuit,100 A 50 °C - 10 s for power circuit,75 A 50 °C - 30 s for power circuit,55 A 50 °C - 1 min for power circuit,50 A 50 °C - 3 min for power circuit,80 A - 1 s for signalling circuit,90 A - 500 ms for signalling circuit,110 A - 100 ms for signalling circuit,25 A 50 °C - >= 15 min for power circuit
Associated fuse rating 25 A gG at <= 440 V for power circuit,25 A aM for power circuit,10 A gG for signalling circuit conforming to IEC 60947,10 A gG for signalling circuit conforming to VDE 0660
Average impedance 3 mOhm - Ith 20 A 50 Hz for power circuit
[Ui] rated insulation voltage Power circuit: 600 V conforming to UL 508,Power circuit: 690 V conforming to IEC 60947-4-1,Signalling circuit: 690 V conforming to IEC 60947-4-1,Signalling circuit: 690 V conforming to IEC 60947-5-1,Signalling circuit: 600 V conforming to UL 508,Power circuit: 600 V conforming to CSA C22.2 No 14,Signalling circuit: 600 V conforming to CSA C22.2 No 14
Electrical durability 1.3 Mcycles 16 A AC-3 at Ue <= 440 V
Interlocking type Mechanical
mounting support Plate,Rail
Standards EN/IEC 60947-4-1,EN/IEC 60947-5-1
Product certifications CB Scheme,CCC,UL,CSA,EAC,CE,UKCA
Connections - terminals Screw clamp terminals 1 cable(s) 1.5…4 mm²solid,Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end,Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end,Screw clamp terminals 2 cable(s) 1.5…4 mm²solid,Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end,Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end
Tightening torque 1.3 N.m - on screw clamp terminals - with screwdriver Philips No 2,1.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
Operating time 10...20 ms coil energisation and NO closing,10...20 ms coil de-energisation and NO opening
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1,B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability 5 Mcycles
Maximum operating rate 3600 cyc/h

Complementary

Control circuit voltage limits Drop-out: 0.2...0.75 Uc (at <50 °C),Operational: 0.85...1.15 Uc (at <50 °C)
Inrush power in VA 30 VA (at 20 °C)
Hold-in power consumption in VA 4.5 VA (at 20 °C)
Heat dissipation 1.3 W
Auxiliary contacts type type instantaneous 1 NO
Signalling circuit frequency <= 400 Hz
Minimum switching current 5 mA for signalling circuit
Minimum switching voltage 17 V for signalling circuit
Non overlap distance 0.5 mm
Insulation resistance > 10 MOhm for signalling circuit

Environment

IP degree of protection IP20 conforming to VDE 0106
Protective treatment TC conforming to IEC 60068,TC conforming to DIN 50016
Ambient air temperature for operation -25…50 °C
Ambient air temperature for storage -50…80 °C
Operating altitude 2000 m without derating
Flame retardance V1 conforming to UL 94,Requirement 2 conforming to NF F 16-101,Requirement 2 conforming to NF F 16-102
Mechanical robustness Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27,Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27,Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27,Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27,Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27,Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27,Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6,Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Height 58 mm
Width 90 mm
Depth 57 mm
net weight 0.39 kg

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 6 cm
Package 1 Width 6.2 cm
Package 1 Length 9.2 cm
Package 1 Weight 0.39 kg

Contractual warranty

Warranty 18 months

Documentation

Product Datasheet

Instruction sheet

CAD

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible