This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Schneider Electric

LD4LD030MC

LD4LD030MC Schneider Electric

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for LD4LD030MC Schneider Electric

LD4LD030MC Schneider Electric - TeSys Integral - contactor breaker - 63 A A AC-43 - 230...240 V AC coil

Free Delivery to UK Mainland on orders over £25

Main

Range TeSys
Product name TeSys Integral 63
product or component type Contactor breaker
Device short name LD4LD

Complementary

Utilisation category AC-43,AC-1
Poles description 3P
[Ue] rated operational voltage 690 V AC 50/60 Hz
[Ie] rated operational current 63 A AC AC-1,63 A AC AC-43
[Ith] conventional free air thermal current 63 A (at 40 °C)
Motor power kW 15 kW at 220...240 V AC 50/60 Hz,30 kW at 400 V AC 50/60 Hz,33 kW at 415 V AC 50/60 Hz,37 kW at 500 V AC 50/60 Hz,55 kW at 660 V AC 50/60 Hz,33 kW at 440 V AC 50/60 Hz
[Uc] control circuit voltage 230...240 V AC 60 Hz
Test function Self test
Control type Knob emergency stop red front conforming to CNOMO
Irms rated making capacity 756 A conforming to IEC 60947-4,946 A conforming to IEC 60947-4
[Ipk] rated peak withstand current 105 kA conforming to IEC 60947-2
Breaking capacity Icu 10 kA at 600...690 V (cos φ 0.5) conforming to IEC 60947-2,Icu 30 kA at 480...525 V (cos φ 0.25) conforming to IEC 60947-6-2,Icu 50 kA at <= 440 V (cos φ 0.25) conforming to IEC 60947-2
[Ics] rated service breaking capacity 10 kA at 600...690 V conforming to IEC 60947-2,35 kA at 480...525 V conforming to IEC 60947-2,50 kA at <= 440 V conforming to IEC 60947-2
Maximum breaking time 4 ms
thermal stress limit 300000 A².s
[Uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947-4
Control circuit voltage limits 0.25...0.7 Uc drop-out 55 °C,0.85...1.1 Uc operation 55 °C
[Ui] rated insulation voltage 690 V conforming to IEC 60947-1
Inrush power in VA 450 VA 60 Hz (at 20 °C)
Hold-in power consumption in VA 25 VA (at 20 °C)
Heat dissipation 5 W at 32 A per pole, hot state for power circuit,7 W at 50 A per pole, hot state for power circuit,9 W at 63 A per pole, hot state for power circuit,4.4 W at 25 A per pole, hot state for power circuit,5.8 W at 40 A per pole, hot state for power circuit,11 W at 60 Hz for control circuit
Operating time 12...35 ms AC network closing at 20 °C for control circuit,7...20 ms AC network opening at 20 °C for control circuit
Electrical durability 1 Mcycles on AC-3 3 kA at 415 V - after 1 cycle O-CO-r-CO at Isc,0.9 Mcycles on AC-3 10 kA at 415 V - after 1 cycle O-CO-r-CO at Isc,0.6 Mcycles on AC-3 25 kA at 415 V - after 1 cycle O-CO-r-CO at Isc,0.5 Mcycles on AC-3 35 kA at 415 V - after 1 cycle O-CO-r-CO at Isc,0.2 Mcycles on AC-3 50 kA at 415 V - after 1 cycle O-CO-r-CO at Isc
Mechanical durability 1.2 Mcycles
Connections - terminals Power circuit: screw clamp terminals 1 cable(s) 6…50 mm² - flexible - without cable end,Power circuit: screw clamp terminals 2 cable(s) 6…25 mm² - flexible - without cable end,Power circuit: screw clamp terminals 1 cable(s) 6…25 mm² - flexible - with cable end,Power circuit: screw clamp terminals 2 cable(s) 6…25 mm² - flexible - with cable end,Power circuit: screw clamp terminals 1 cable(s) 6…50 mm² - solid
Tightening torque Power circuit: 6 N.m - on screw clamp terminals
Width 90 mm
Height 243 mm
Depth 192 mm
net weight 3.8 kg

Environment

Standards BS 4941,IEC 60204-2,VDE 0110,IEC 60947-1,IEC 60158-1,VDE 471,VDE 0100,NF C 20-040,NF C 63-120,IEC 60204-1,BS 4752,IEC 60947-2,BS 5424,NF C 63-650,IEC 60947-4,NF C 79-100,NF C 63-110,NF C 63-130,NEN,VDE 0113,NBN,VDE 0171,VDE 0170,IEC 60364,VDE 0660
Product certifications UL,SETI,NEMKO,ASEFA,RINA,LROS (Lloyds register of shipping),DNV,NKK,DEMKO,ASE,BV,OVE,GL,SCC,USSR,CSA,ASTA
Protective treatment TH
Ambient air temperature for operation -20…60 °C
Ambient air temperature for storage -40…80 °C
Mechanical robustness Vibrations de-energised: 3 Gn, 1...300 Hz,Vibrations energised: 3 Gn, 1...300 Hz,Shocks de-energised: 8 Gn for 11 ms,Shocks energised: 8 Gn for 11 ms
IP degree of protection IP20 B conforming to IEC 60144,IP20 B conforming to IEC 60529
Operating altitude 3000 m without derating

Contractual warranty

Warranty 18 months

Documentation

Product Datasheet

Instruction sheet

CAD

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible