LMC20A1309 Schneider Electric - Lexium motion servo drive Controller - 24 V DC - 0.5 A

Free Delivery to UK Mainland on orders over £25

Main

range of product Lexium Controller
product or component type Motion servo drive controllers
Component name LMC
Type of polarization 10 kOhm for Modbus protocol

Complementary

power supply voltage 24 V
power supply circuit type DC
power supply voltage limits 19…30 V
Maximum supply current 0.5 A
Inrush current 10 A for 0.2 ms
Discrete input number 1 master encoder discrete input(s),2 event-triggered discrete input(s),2 touch probe discrete input(s),8 discrete discrete input(s)
Discrete input type 12 mA master encoder input for 2 kOhm,7 mA discrete input for 3 kOhm,7 mA event-triggered input for 3 kOhm,7 mA touch probe input for 3 kOhm
Discrete input voltage 5.5 V DC for master encoder input,24 V DC (voltage limits: 19...30 V) for discrete input,24 V DC (voltage limits: 19...30 V) for event-triggered input,24 V DC (voltage limits: 19...30 V) for touch probe input
Discrete input logic Positive logic (source) for discrete input
Electrical connection 1 HE-10 connector discrete input,1 HE-10 connector event-triggered input,1 HE-10 connector touch probe input,1 high density 15-way female SUB-D connector master encoder input
Filter time 0.5 µs at state 0 for touch probe input(s),1 µs at state 1 for touch probe input(s),15 µs at state 1 for discrete input(s),15 µs at state 1 for event-triggered input(s),70 µs at state 0 for discrete input(s),70 µs at state 0 for event-triggered input(s)
Insulation Discrete input for between input channels with internal logic via optical coupler,Event-triggered input for between input channels with internal logic via optical coupler,Logic output for between output channels with internal logic via optical coupler,Master encoder input for 2500 V,Touch probe input for between input channels with internal logic via optical coupler
Input compatibility Encoder with open collector output, 5 V power supplied for master encoder,Encoder with push-pull output, 5 V power supplied for master encoder,Encoder with RS422 compatible differential outputs, 5 or 24 V power supplied for master encoder,Universal encoder with SSI output, 24 V power supplied for master encoder
Discrete output number 8
Discrete output logic 2 positive logic (source)
Discrete output voltage 24 V DC 19...30 V
Discrete output current 200 mA
Maximum output short-circuit current 1 A
Response time 150 µs at state 1 for logic output,250 µs at state 0 for logic output
Memory type Flash EPROM 1 MB application,NVRAM 60 kB data storage,RAM 1 MB application
Realtime clock Built-in for 20 days
Application structure 1 master task,1 auxiliary task,2 event-triggered tasks
Cycle time 2 ms for 4 synchronized axes,4 ms for 8 synchronized axes
Exact time for 1 Kinstruction < 120 µs (in structured language, 60 % Boolean, 20 % numerical, 20 % floating point)
communication port protocol CANopen Motionbus,Modbus protocol,Modbus TCP network,CANopen machine bus,DeviceNet fieldbus
Connector type 1 RJ45 for Modbus protocol,1 RJ45 for Modbus TCP network,9-way male SUB-D connector for CANopen machine bus,9-way male SUB-D connector for CANopen Motionbus,Screw-type, 5 contacts, 5.08 pitch for DeviceNet fieldbus
Physical interface 2-wire RS 485 for Modbus protocol,2-wire RS 485 for Modbus TCP network,Ethernet 2 for Modbus TCP network
Exchange mode Half duplex and full duplex Modbus TCP network
Communication data link LLC : IEEE 802.2 for Modbus TCP network,MAC : IEEE 802.3 for Modbus TCP network
Communication network type ICMP,IP conforming to RFC791
Communication transport type TCP conforming to RFC793,UDP
Mode of transmission RTU for Modbus protocol
Transmission rate 1 Mbps for bus length of 15 m for CANopen machine bus,1 Mbps for bus length of 15 m for CANopen Motionbus,10/100 Mbps, autodetected for Modbus TCP network,125 kbps, 250 kbps or 500 kbps for DeviceNet fieldbus,19.6 kbps or 38.4 kbps for Modbus protocol,250 kbps for bus length of 250 m for CANopen Motionbus,50 kbps for bus length of 1000 m for CANopen machine bus,500 kbps for bus length of 80 m for CANopen Motionbus
Method of access Master CANopen machine bus,Master CANopen Motionbus,Slave Modbus protocol
Data format 8 bits, no parity, 1 stop for Modbus protocol
Number of addresses 1…32 for CANopen machine bus,1…63 for DeviceNet fieldbus,1…247 for Modbus protocol
Installed device 8 Lexium 05 or Lexium 15 servo drives or SD3 28A stepper drives for CANopen Motionbus
Web server Class C20, Modbus TCP network
Communication service 10 PDOs per slave for CANopen machine bus,2 SDOs per cycle for CANopen machine bus,CiA DSP 301 V4.02 for CANopen machine bus,CiA DSP 405 for CANopen machine bus,Note guarding, heartbeat for CANopen machine bus,2 PDOs per slave (1 transmit and 1 receive) for CANopen Motionbus,2 SDOs per cycle (1 read and 1 write) for CANopen Motionbus,CiA DSP 301 V4.02 for CANopen Motionbus,CiA DSP 405 for CANopen Motionbus,Emergency for CANopen Motionbus,Note guarding, heartbeat for CANopen Motionbus,Communication scanner assemblies 100 and 101 for DeviceNet fieldbus,Monitoring inhibitable for DeviceNet fieldbus,Periodic exchange mode on inputs : polled, change of state, cyclic for DeviceNet fieldbus,Periodic exchange mode on outputs : polled for DeviceNet fieldbus,Time out can be set for DeviceNet fieldbus,Configurable time out for Modbus protocol,Diagnostics (08) for Modbus protocol,Read device identification (43) for Modbus protocol,Read holding registers (03), 121 words maximum for Modbus protocol,Write multiple registers (16), 121 words maximum for Modbus protocol,Write single register (06) for Modbus protocol,BOOTP for Modbus TCP network,DHCP for Modbus TCP network,Diagnostics (08) for Modbus TCP network,FTP for web server for Modbus TCP network,Monitoring inhibitable for Modbus TCP network,Read device identification (43) for Modbus TCP network,Read holding registers (03), 121 words maximum for Modbus TCP network,SNMP for Modbus TCP network,Time out adjustable from 0.5...60 s for Modbus TCP network,Write multiple registers (16), 121 words maximum for Modbus TCP network,Write single register (06) for Modbus TCP network
Local signalling 1 LED - activity for CANopen machine bus,1 LED - activity for CANopen Motionbus,1 LED - activity for DeviceNet fieldbus,1 LED - activity for Modbus protocol,1 LED - activity for Modbus TCP network
marking CE
net weight 1.079 kg

Environment

Electromagnetic compatibility Electrostatic discharge level 3 conforming to EN/IEC 61000-4-2,Immunity to electrical transients level 4 conforming to EN/IEC 61000-4-4,Immunity to radiated radio-electrical interference level 3 conforming to EN/IEC 61000-4-3,Voltage/current impulse level 3 conforming to EN/IEC 61000-4-5
Standards EN/IEC 61800-3 environment 1,EN/IEC 61800-5-1,EN/IEC 61800-3 environment 2
Product certifications GOST,UL,C-Tick,CCC,CSA
IP degree of protection IP20
Vibration resistance 1 gn (f= 13…200 Hz) conforming to EN/IEC 60068-2-6,1.5 mm (f= 5…13 Hz) conforming to EN/IEC 60068-2-6
Shock resistance 15 gn for 11 ms conforming to EN/IEC 60068-2-27
Relative humidity 10…95 % for operation, without condensation,5…95 % for storage, without condensation conforming to IEC 61131-2
Ambient air temperature for operation 0…50 °C
Ambient air temperature for storage -25…70 °C conforming to IEC 61131-2
Operating altitude 0...2000 m

Contractual warranty

Warranty 18 months

Documentation

Product Datasheet