This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Schneider Electric

LP1D40004GD

LP1D40004GD Schneider Electric

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for LP1D40004GD Schneider Electric

LP1D40004GD Schneider Electric - contactor - TeSys LP1-D - 4 poles - AC-1 440V 60 A - coil 125 V DC

Free Delivery to UK Mainland on orders over £25

Main

range of product TeSys Deca
product or component type Contactor
Device short name LP1D
Contactor application Resistive load
Utilisation category AC-1,AC-3,AC-3e,AC-4
Poles description 4P
[Ue] rated operational voltage Power circuit: <= 690 V AC 25...400 Hz
[Ie] rated operational current 60 A (at <60 °C) AC AC-1 for power circuit
[Uc] control circuit voltage 125 V DC

Complementary

compatibility code LP1D
Pole contact composition 4 NO
Protective cover With
[Ith] conventional free air thermal current 10 A (at 60 °C) for control circuit,60 A (at 60 °C) for power circuit
Irms rated making capacity 250 A AC for control circuit conforming to IEC 60947-5-1,800 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity 800 A at 440 V for power circuit conforming to IEC 60947
Associated fuse rating 10 A gG for control circuit conforming to IEC 60947-5-1,80 A gG at <= 690 V coordination type 1 for power circuit,80 A gG at <= 690 V coordination type 2 for power circuit
Average impedance 1.5 mOhm - Ith 60 A 50 Hz for power circuit
Power dissipation per pole 5.4 W AC-1
[Ui] rated insulation voltage Control circuit: 600 V CSA certified,Control circuit: 600 V UL certified,Power circuit: 600 V CSA certified,Power circuit: 600 V UL certified,Control circuit: 690 V conforming to IEC 60947-1,Power circuit: 690 V conforming to IEC 60947-1
Overvoltage category III
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
Mechanical durability 10000000 cycles
Control circuit type DC standard
Coil technology Built-in bidirectional peak limiting diode suppressor
Control circuit voltage limits 0.1...0.3 Uc (60 °C):drop-out DC,0.75...1.25 Uc (60 °C):operational DC
Inrush power in W 19 W (at 20 °C)
Hold-in power consumption in W 7.4 W at 20 °C
Rated operational power in W 12 W at 125 V DC-13 - electrical durability: 10000000 cycles - for control circuit,38 W at 125 V DC-13 - electrical durability: 3000000 cycles - for control circuit,76 W at 125 V DC-13 - electrical durability: 1000000 cycles - for control circuit
Operating time 20 ms opening,50 ms closing
Time constant 34 ms
Maximum operating rate 3600 cyc/h 60 °C
Connections - terminals Control circuit: screw clamp terminal 1 1…4 mm² - cable stiffness: solid without cable end,Control circuit: screw clamp terminal 2 1…2.5 mm² - cable stiffness: flexible with cable end,Control circuit: screw clamp terminal 2 1…4 mm² - cable stiffness: flexible without cable end,Control circuit: screw clamp terminal 2 1…4 mm² - cable stiffness: solid without cable end,Power circuit: screw clamp terminal 1 1…35 mm² - cable stiffness: solid without cable end,Power circuit: screw clamp terminal 2 1…25 mm² - cable stiffness: solid without cable end,Power circuit: screw clamp terminal 2 1…35 mm² - cable stiffness: solid without cable end
Tightening torque Control circuit: 1.2 N.m - on screw clamp terminal - with screwdriver flat Ø 6 mm,Control circuit: 1.2 N.m - on screw clamp terminal - with screwdriver Philips No 2,Power circuit: 5 N.m - on screw clamp terminal - with screwdriver flat Ø 6 to Ø 8 mm hexagonal screw head
Auxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1, type mirror contact 1 NC conforming to IEC 60947-4-1
Minimum switching voltage 17 V for control circuit
Minimum switching current 5 mA for control circuit
Insulation resistance > 10 MOhm for control circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contacts,1.5 ms on energisation between NC and NO contacts
mounting support Plate,Rail

Environment

Standards NF C 63-110,EN 60947-4-1,BS 5424,IEC 60947-4-1,IEC 60947-1,EN 60947-1,JEM 1038,VDE 0660
Product certifications Sichere trennung,UL,DNV,GL,RINA,GOST,PTB,CSA,SNCF
IP degree of protection IP2X conforming to IEC 60529,IP2X conforming to VDE 0106
Protective treatment TH (pollution degree 3) conforming to IEC 60068
Permissible ambient air temperature around the device -5…60 °C,-40…70 °C at Uc
Operating altitude 3000 m without derating
Fire resistance 850 °C conforming to IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Shocks contactor open (8 Gn for 11 ms) ,Shocks contactor closed (10 Gn for 11 ms) ,Vibrations contactor opened (2 Gn, 5...300 Hz) ,Vibrations contactor closed (4 Gn, 5...300 Hz)
Height 127 mm
Width 85 mm
Depth 182 mm
net weight 2.21 kg

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 19.5 cm
Package 1 Width 10 cm
Package 1 Length 14 cm
Package 1 Weight 2.23 kg

Contractual warranty

Warranty 18 months

Documentation

Product Datasheet

CAD

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible