Description for LP1D800046SW Schneider Electric

LP1D800046SW Schneider Electric - TeSys D contactor - 4P(4 NO) - AC-1 - <= 440 V 125 A - 72 V DC coil

Extended Description for LP1D800046SW Schneider Electric

LP1D800046SW Schneider Electric - TeSys Deca contactor, 4P(4NO) for category AC-1 applications up to 125A @440V.,It provides with 72V DC wide range coil, with no auxiliary contacts, power and control connections by bars/lugs-ring terminals.,It procures with 4 Mcycles mechanical durability and 0.8 Mcycles electrical durability.,It provides IP20 protection on front face conforming to IEC 60529.,It can cover -40°C to 60°C operation temperature and without derating under 3000m altitude.,Designed for demanding applications with maximum operating rates up to 3600 cycles per hour under maximum 60°C.,The dimension is 127mm x 96mm x 181mm (H x W x D), mounting on rail or plate.,Multi standards certified(UL,LROS,DNV,GOST,RINA,CSA,CCC,BV,GL) and Green Premium compliant (RoHs/Reach).

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Available on back order
4 - 6 W.Weeks
£327.97 Exc. VAT
£393.56 Inc. VAT

Main

Range TeSys
range of product TeSys Deca
product or component type Contactor
Device short name LP1D
Contactor application Resistive load
Utilisation category AC-1,AC-3,AC-3e,AC-4
Poles description 4P
[Ue] rated operational voltage Power circuit: <= 690 V AC 25...400 Hz,Power circuit: <= 300 V DC
[Ie] rated operational current 125 A (at <60 °C) at <= 440 V AC AC-1 for power circuit,80 A (at <60 °C) at <= 440 V AC AC-3 for power circuit,80 A (at <60 °C) at <= 440 V AC AC-3e for power circuit,55 A (at <60 °C) at <= 400 V AC AC-4 for power circuit
[Uc] control circuit voltage 72 V DC

Complementary

compatibility code LP1D
Pole contact composition 4 NO
Protective cover Without
[Ith] conventional free air thermal current 125 A (at 60 °C) for power circuit
Irms rated making capacity 1100 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity 1100 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 135 A 40 °C - 10 min for power circuit,320 A 40 °C - 1 min for power circuit,640 A 40 °C - 10 s for power circuit,990 A 40 °C - 1 s for power circuit
Associated fuse rating 200 A gG at <= 690 V coordination type 1 for power circuit,160 A gG at <= 690 V coordination type 2 for power circuit
Average impedance 0.8 mOhm - Ith 125 A 50 Hz for power circuit
Power dissipation per pole 12.5 W AC-1
[Ui] rated insulation voltage Power circuit: 600 V CSA certified,Power circuit: 600 V UL certified,Power circuit: 1000 V conforming to IEC 60947-4-1
Overvoltage category III
Pollution degree 3
[Uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1,B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability 4 Mcycles
Electrical durability 0.8 Mcycles 125 A AC-1 at Ue <= 440 V
Control circuit type DC wide range
Coil technology Without built-in suppressor module
Control circuit voltage limits 0.1...0.3 Uc (-40…70 °C):drop-out DC,0.75...1.2 Uc (-40…55 °C):operational DC,1...1.2 Uc (55…70 °C):operational DC
Inrush power in W 22 W (at 20 °C)
Hold-in power consumption in W 22 W at 20 °C
Operating time 6...20 ms opening,20...35 ms closing
Time constant 75 ms
Maximum operating rate 3600 cyc/h 60 °C
Connections - terminals Control circuit: lugs-ring terminals - external diameter: 8 mm,Power circuit: lugs-ring terminals - external diameter: 17 mm,Power circuit: bars 1 - busbar cross section: 3 x 16 mm
Tightening torque Control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver flat Ø 6 mm M3.5,Control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver Philips No 2 M3.5,Power circuit: 12 N.m - on lugs-ring terminals hexagonal screw head 10 mm M6,Power circuit: 12 N.m - on lugs-ring terminals - with screwdriver flat Ø 8 mm M6,Power circuit: 12 N.m - on bars - with screwdriver flat Ø 8 mm M6,Power circuit: 12 N.m - on bars hexagonal screw head 10 mm M6,Control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver pozidriv No 2 M3.5
mounting support Rail,Plate

Environment

Standards CSA C22.2 No 14,EN 60947-4-1,EN 60947-5-1,IEC 60947-4-1,IEC 60947-5-1,UL 508
Product certifications BV,CCC,CSA,DNV,EAC,GL,LROS (Lloyds register of shipping),UL,UKCA
IP degree of protection IP20 front face conforming to IEC 60529
Permissible ambient air temperature around the device -40…60 °C,60…70 °C with derating
Operating altitude 0...3000 m
Fire resistance 850 °C conforming to IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Vibrations contactor open (2 Gn, 5...300 Hz) ,Vibrations contactor closed (3 Gn, 5...300 Hz) ,Shocks contactor open (8 Gn for 11 ms) ,Shocks contactor closed (10 Gn for 11 ms)
Height 127 mm
Width 96 mm
Depth 181 mm
net weight 2.685 kg

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 11.0 cm
Package 1 Width 14.0 cm
Package 1 Length 20.5 cm
Package 1 Weight 2.74 kg

Contractual warranty

Warranty 18 months

Documentation

Product Datasheet

Instruction sheet

CAD

Environmental disclosure

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible