This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Schneider Electric

LP1K09004FD

LP1K09004FD Schneider Electric

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for LP1K09004FD Schneider Electric

LP1K09004FD Schneider Electric - TeSys K contactor - 4P (4 NO) - AC-1 <= 440 V 20 A - 110 V DC coil

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Available on back order
4 - 6 W.Weeks
£19.12 Exc. VAT
£22.94 Inc. VAT

Main

Range TeSys
product or component type Contactor
Device short name LP1K
Contactor application Resistive load

Complementary

Utilisation category AC-1
Poles description 4P
power pole contact composition 4 NO
[Ue] rated operational voltage Power circuit: <= 690 V AC <= 400 Hz,Signalling circuit: <= 690 V AC <= 400 Hz
[Ie] rated operational current 20 A (at <60 °C) at <= 690 V AC AC-1 for power circuit
Control circuit type DC standard
[Uc] control circuit voltage 110 V DC
[Uimp] rated impulse withstand voltage 8 kV
Overvoltage category III
[Ith] conventional free air thermal current 20 A (at 60 °C) for power circuit,10 A (at 50 °C) for signalling circuit
Irms rated making capacity 110 A AC for power circuit conforming to IEC 60947
Rated breaking capacity 110 A at 220...230 V conforming to IEC 60947,110 A at 380...400 V conforming to IEC 60947,110 A at 415 V conforming to IEC 60947,110 A at 440 V conforming to IEC 60947,80 A at 500 V conforming to IEC 60947,70 A at 660...690 V conforming to IEC 60947
[Icw] rated short-time withstand current 90 A 50 °C - 1 s for power circuit,85 A 50 °C - 5 s for power circuit,80 A 50 °C - 10 s for power circuit,60 A 50 °C - 30 s for power circuit,45 A 50 °C - 1 min for power circuit,40 A 50 °C - 3 min for power circuit,20 A 50 °C - >= 15 min for power circuit
Associated fuse rating 25 A gG at <= 440 V for power circuit,25 A aM for power circuit
Average impedance 3 mOhm - Ith 20 A 50 Hz for power circuit
[Ui] rated insulation voltage Power circuit: 600 V conforming to UL 508,Power circuit: 690 V conforming to IEC 60947-4-1,Power circuit: 600 V conforming to CSA C22.2 No 14
Inrush power in W 3 W (at 20 °C)
Hold-in power consumption in W 3 W at 20 °C
Heat dissipation 1.3 W
Control circuit voltage limits Operational: 0.8...1.15 Uc (at <50 °C),Drop-out: >= 0.10 Uc (at <50 °C)
Connections - terminals Screw clamp terminals 1 cable(s) 1.5…4 mm²solid,Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end,Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end,Screw clamp terminals 2 cable(s) 1.5…4 mm²solid,Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end,Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end,Power circuit: screw clamp terminals 2 cable(s) 1.5 mm²flexible with cable end
Maximum operating rate 3600 cyc/h
mounting support Rail,Plate
Tightening torque 0.8…1.3 N.m - on screw clamp terminals Philips No 2,0.8…1.3 N.m - on screw clamp terminals flat Ø 6 mm,0.8…1.3 N.m - on screw clamp terminals pozidriv No 2
Operating time 30...40 ms coil energisation and NO closing,10 ms coil de-energisation and NO opening
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1,B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability 10 Mcycles
Electrical durability 0.16 Mcycles 20 A AC-1 at Ue <= 690 V
Height 58 mm
Width 45 mm
Depth 57 mm
net weight 0.225 kg

Environment

Standards EN/IEC 60947-4-1,EN/IEC 60947-5-1,UL 60947-4-1,UL 60947-5-1,CSA C22.2 No 60947-4-1,CSA C22.2 No 60947-5-1,GB/T 14048.4
Product certifications CB Scheme,CCC,UL,CSA,EAC,CE,UKCA
IP degree of protection IP2X
Ambient air temperature for operation -25…50 °C
Ambient air temperature for storage -50…80 °C
Operating altitude 2000 m without derating
Flame retardance V1 conforming to UL 94,Requirement 2 conforming to NF F 16-101,Requirement 2 conforming to NF F 16-102

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 6.600 cm
Package 1 Width 6.600 cm
Package 1 Length 6.600 cm
Package 1 Weight 217.000 g
Unit Type of Package 2 S02
Number of Units in Package 2 40
Package 2 Height 15.000 cm
Package 2 Width 30.000 cm
Package 2 Length 40.000 cm
Package 2 Weight 9.135 kg

Contractual warranty

Warranty 18 months

Documentation

Product Datasheet

Instruction sheet

Catalogue

CAD

Environmental disclosure

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible