This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Schneider Electric

LP2K09004MD

LP2K09004MD Schneider Electric

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for LP2K09004MD Schneider Electric

LP2K09004MD Schneider Electric - TeSys K changeover contactor - 4P - AC-1 <= 440 V 20 A - 220 V DC coil

Free Delivery to UK Mainland on orders over £25

Main

Range TeSys
Product name TeSys K
product or component type Changeover contactor
Device short name LP2K
device application Control
Contactor application Resistive load
Utilisation category AC-1
Device presentation Preassembled with reversing power busbar
Poles description 4P
power pole contact composition 4 NO
[Ue] rated operational voltage Power circuit: 690 V AC 50/60 Hz
[Ie] rated operational current 20 A (at <50 °C) at <= 440 V AC AC-1 for power circuit,16 A (at <70 °C) at 690 V AC AC-1 for power circuit
Control circuit type DC standard
[Uc] control circuit voltage 220 V DC
[Uimp] rated impulse withstand voltage 8 kV
Overvoltage category III
[Ith] conventional free air thermal current 20 A (at 50 °C) for power circuit
Irms rated making capacity 110 A AC for power circuit conforming to NF C 63-110,110 A AC for power circuit conforming to IEC 60947
Rated breaking capacity 110 A at 415 V conforming to IEC 60947,110 A at 440 V conforming to IEC 60947,80 A at 500 V conforming to IEC 60947,110 A at 220...230 V conforming to IEC 60947,110 A at 380...400 V conforming to IEC 60947,70 A at 660...690 V conforming to IEC 60947
[Icw] rated short-time withstand current 90 A 50 °C - 1 s for power circuit,85 A 50 °C - 5 s for power circuit,80 A 50 °C - 10 s for power circuit,60 A 50 °C - 30 s for power circuit,45 A 50 °C - 1 min for power circuit,40 A 50 °C - 3 min for power circuit,20 A 50 °C - >= 15 min for power circuit
Associated fuse rating 25 A gG at <= 440 V for power circuit,25 A aM for power circuit
Average impedance 3 mOhm - Ith 20 A 50 Hz for power circuit
[Ui] rated insulation voltage Power circuit: 600 V conforming to UL 508,Power circuit: 690 V conforming to IEC 60947-4-1,Power circuit: 600 V conforming to CSA C22.2 No 14
Electrical durability 0.18 Mcycles 20 A AC-1 at Ue <= 440 V
Interlocking type Mechanical
mounting support Rail,Plate
Standards EN/IEC 60947-4-1,GB/T 14048.4,UL 60947-4-1,CSA C22.2 No 60947-4-1,JIS C8201-4-1
Product certifications CB Scheme,CCC,UL,CSA,EAC,CE,UKCA
Connections - terminals Screw clamp terminals 1 cable(s) 1.5…4 mm²solid,Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end,Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end,Screw clamp terminals 2 cable(s) 1.5…4 mm²solid,Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end,Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end
Tightening torque 0.8…1.3 N.m - on screw clamp terminals Philips No 2,0.8…1.3 N.m - on screw clamp terminals flat Ø 6 mm
Operating time 30...40 ms coil energisation and NO closing,10 ms coil de-energisation and NO opening
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1,B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability 5 Mcycles
Maximum operating rate 3600 cyc/h

Complementary

Control circuit voltage limits Operational: 0.8...1.15 Uc (at <50 °C),Drop-out: 0.1...0.75 Uc (at <50 °C)
Inrush power in W 3 W (at 20 °C)
Hold-in power consumption in W 3 W at 20 °C
Heat dissipation 3 W

Environment

IP degree of protection IP20 conforming to VDE 0106
Protective treatment TC conforming to IEC 60068,TC conforming to DIN 50016
Ambient air temperature for operation -25…50 °C
Ambient air temperature for storage -50…80 °C
Operating altitude 2000 m without derating
Flame retardance V1 conforming to UL 94,Requirement 2 conforming to NF F 16-101,Requirement 2 conforming to NF F 16-102
Mechanical robustness Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27,Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27,Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6,Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6,Shocks contactor opened, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27,Shocks contactor opened, on Y axis: 6 Gn for 11 ms conforming to IEC 60068-2-27,Shocks contactor closed, on X axis: 15 Gn for 11 ms conforming to IEC 60068-2-27,Shocks contactor closed, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Height 58 mm
Width 90 mm
Depth 57 mm
net weight 0.48 kg

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 6 cm
Package 1 Width 6.2 cm
Package 1 Length 9.2 cm
Package 1 Weight 480 g

Contractual warranty