Description for LP4K12103BW3 Schneider Electric

LP4K12103BW3 Schneider Electric - TeSys K contactor - 3P - AC-3 <= 440 V 12 A - 1 NO aux. - 24 V DC coil

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Available on back order
4 - 6 W.Weeks
£29.18 Exc. VAT
£35.02 Inc. VAT

Main

Range TeSys
product or component type Contactor
Device short name LP4K
Contactor application Resistive load,Motor control

Complementary

Utilisation category AC-3,AC-3e,AC-1,AC-4
Poles description 3P
power pole contact composition 3 NO
[Ue] rated operational voltage Power circuit: <= 690 V AC <= 400 Hz,Signalling circuit: <= 690 V AC <= 400 Hz
[Ie] rated operational current 12 A (at <60 °C) at <= 440 V AC AC-3 for power circuit,12 A (at <60 °C) at <= 440 V AC AC-3e for power circuit,20 A (at <60 °C) at <= 690 V AC AC-1 for power circuit
Control circuit type DC wide range
[Uc] control circuit voltage 24 V DC
Motor power kW 3 kW at 220...230 V AC 50/60 Hz AC-3,5.5 kW at 380...415 V AC 50/60 Hz AC-3,5.5 kW at 440 V AC 50/60 Hz AC-3,4 kW at 690 V AC 50/60 Hz AC-3,3 kW at 220...230 V AC 50/60 Hz AC-3e,5.5 kW at 380...415 V AC 50/60 Hz AC-3e,5.5 kW at 440 V AC 50/60 Hz AC-3e,4 kW at 690 V AC 50/60 Hz AC-3e,3 kW at 220...230 V AC 50/60 Hz AC-4,5.5 kW at 380...415 V AC 50/60 Hz AC-4,5.5 kW at 440 V AC 50/60 Hz AC-4
Auxiliary contact composition 1 NO
[Uimp] rated impulse withstand voltage 8 kV
Overvoltage category III
[Ith] conventional free air thermal current 16 A (at 60 °C) for power circuit,10 A (at 50 °C) for signalling circuit
Irms rated making capacity 144 A AC for power circuit conforming to IEC 60947,110 A AC for signalling circuit conforming to IEC 60947
Rated breaking capacity 110 A at 440 V conforming to IEC 60947,80 A at 500 V conforming to IEC 60947,70 A at 660...690 V conforming to IEC 60947
[Icw] rated short-time withstand current 115 A 50 °C - 1 s for power circuit,105 A 50 °C - 5 s for power circuit,100 A 50 °C - 10 s for power circuit,75 A 50 °C - 30 s for power circuit,55 A 50 °C - 1 min for power circuit,50 A 50 °C - 3 min for power circuit,25 A 50 °C - >= 15 min for power circuit,80 A - 1 s for signalling circuit,90 A - 500 ms for signalling circuit,110 A - 100 ms for signalling circuit
Associated fuse rating 25 A gG at <= 440 V for power circuit,25 A aM for power circuit,10 A gG for signalling circuit conforming to IEC 60947,10 A gG for signalling circuit conforming to VDE 0660
Average impedance 3 mOhm - Ith 16 A 50 Hz for power circuit
[Ui] rated insulation voltage Power circuit: 600 V conforming to UL 508,Power circuit: 690 V conforming to IEC 60947-4-1,Signalling circuit: 690 V conforming to IEC 60947-4-1,Signalling circuit: 690 V conforming to IEC 60947-5-1,Signalling circuit: 600 V conforming to UL 508,Power circuit: 600 V conforming to CSA C22.2 No 14,Signalling circuit: 600 V conforming to CSA C22.2 No 14
Insulation resistance > 10 MOhm for signalling circuit
Inrush power in W 1.8 W (at 20 °C)
Hold-in power consumption in W 1.8 W at 20 °C
Heat dissipation 1.8 W
Control circuit voltage limits Operational: 0.7...1.3 Uc (at <50 °C),Drop-out: >= 0.10 Uc (at <50 °C)
Connections - terminals Spring terminals 1 cable(s) 0.75…1.5 mm²solid,Spring terminals 1 cable(s) 0.75…1.5 mm²flexible without cable end,Spring terminals 2 cable(s) 0.75…1.5 mm²flexible without cable end
Maximum operating rate 3600 cyc/h
Coil technology Built-in bidirectional peak limiting diode suppressor
Auxiliary contacts type type instantaneous 1 NO
Minimum switching current 5 mA for signalling circuit
Minimum switching voltage 17 V for signalling circuit
mounting support Rail,Plate
Operating time 10...20 ms coil de-energisation and NO opening,30...40 ms coil energisation and NO closing
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1,B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability 30 Mcycles
Electrical durability 1.3 Mcycles 12 A AC-3 at Ue <= 440 V,1.3 Mcycles 12 A AC-3e at Ue <= 440 V,0.3 Mcycles 20 A AC-1 at Ue <= 690 V,0.02 Mcycles 72 A AC-4 at Ue <= 440 V
Height 58 mm
Width 45 mm
Depth 57 mm
net weight 0.235 kg

Environment

Standards EN/IEC 60947-4-1,EN/IEC 60947-5-1,UL 60947-4-1,UL 60947-5-1,CSA C22.2 No 60947-4-1,CSA C22.2 No 60947-5-1,GB/T 14048.4
Product certifications CB Scheme,CCC,UL,CSA,EAC,CE,UKCA
IP degree of protection IP2X
Ambient air temperature for operation -25…50 °C
Ambient air temperature for storage -50…80 °C
Operating altitude 2000 m without derating
Flame retardance V1 conforming to UL 94,Requirement 2 conforming to NF F 16-101,Requirement 2 conforming to NF F 16-102

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 4.8 cm
Package 1 Width 6.2 cm
Package 1 Length 6.5 cm
Package 1 Weight 226.0 g

Contractual warranty

Warranty 18 months

Documentation

Product Datasheet

Instruction sheet

Catalogue

CAD

Environmental disclosure

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible