Description for LT3SM00E Schneider Electric

LT3SM00E Schneider Electric - PTC probe relay TeSys - LT3 with manual reset - 24 V - 1 NO + 1 NC

Extended Description for LT3SM00E Schneider Electric

LT3SM00E Schneider Electric - TeSys LT3 thermistor protection unit for use with PTC probes, with manual reset and fault indicator on front, dual voltage supply 24 or 48V AC 50/60Hz.,To be used with a combination of PTC probes impedance lower than 1500 Ohm at 25°C, the trip impedance zone is 2700-3100 Ohm, the manual reset is possible only if impedance has decreased enough to be below 1500-1650 Ohm.,It provides 2 auxiliary contacts 1NO+1NC for fault signaling, 1 pushbutton on front face for a local manual reset, and 1 logic input for connection of a remote reset button.,DIN rail mounting, connections by cage terminals.,PTC thermistor probes DA1TT, DA1TS available (to be ordered separately).,Multi standards certified (IEC, UL, CSA), Green Premium compliant (RoHS/REACh).

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Available on back order
4 - 6 W.Weeks
£429.18 Exc. VAT
£515.02 Inc. VAT

Main

range of product LT3
Device short name LT3SE
product or component type Thermistor protection units
[Uc] control circuit voltage 24...48 V AC 50/60 Hz
Reset Manual

Complementary

Control circuit voltage limits 0.85...1.1 Uc
Contacts type and composition 1 NC + 1 NO single voltage
[Ith] conventional free air thermal current 5 A for output control relay
[Ui] rated insulation voltage Output control relay: 500 V AC
[Ue] rated operational voltage 250 V AC 50/60 Hz for output control relay
Signalling function Fault indication,Voltage indication
Control type Manual reset,Manual test
Probe interchangeability Label mark A conforming to IEC 60034-11
Hold-in power consumption in VA 2.5 VA
Resistance 1500…1650 Ohm reset,2700…3100 Ohm tripping
Number of probes 0…6
Input voltage < 2.5 V (1500 Ohm) for probe,< 7.5 V (4000 Ohm) for probe conforming to IEC 60034-11
Maximum short circuit detection resistance 20 Ohm
Condition of use Connection of probes 1000 m >2.5 mm²,Connection of probes 500 m >1.5 mm²
[Uimp] rated impulse withstand voltage 2.5 kV
Rated power in VA 100 VA at 220 V - electrical durability: 500000 cycles
Breaking capacity 2 A at 24 V DC DC-13,3 A at 250 V AC AC-16,6 A at 120 V AC AC-16
Connections - terminals Power circuit: cage type connector 1 cable(s) 0.75…2.5 mm²flexible with cable end,Power circuit: cage type connector 1 cable(s) 0.75…2.5 mm²solid with cable end,Power circuit: cage type connector 1 cable(s) 1…2.5 mm²flexible without cable end,Power circuit: cage type connector 1 cable(s) 1…2.5 mm²solid without cable end,Power circuit: cage type connector 2 cable(s) 0.75…2.5 mm²flexible with cable end,Power circuit: cage type connector 2 cable(s) 0.75…2.5 mm²solid with cable end,Power circuit: cage type connector 2 cable(s) 1…2.5 mm²flexible without cable end,Power circuit: cage type connector 2 cable(s) 1…2.5 mm²solid without cable end
Tightening torque 0.8 N.m
Height 100 mm
Width 22.5 mm
Depth 100 mm
net weight 0.22 kg

Environment

Standards IEC 60947-8,IEC 60034-11,VDE 0660
IP degree of protection IP20 conforming to IEC 60529,IP20 conforming to VDE 0106
Ambient air temperature for operation -25…60 °C
Ambient air temperature for storage -40…85 °C conforming to IEC 60068-2-2,-40…85 °C conforming to IEC 60068-2-2
Operating altitude <= 1500 m without derating in temperature,> 1500...3000 m with derating in temperature
Vibration resistance 1 gn 25...150 Hz conforming to IEC 60068-2-6,2.5 gn 2...25 Hz conforming to IEC 60068-2-6
Shock resistance 5 gn 11 ms conforming to IEC 60068-2-27
Electromagnetic compatibility Resistance to electrostatic discharge level 3 conforming to IEC 61000-4-2,Resistance to fast transient level 3 conforming to IEC 61000-4-4,Surge resistance 1.2/50-8/20 level 4 conforming to IEC 61000-4-5,Susceptibility to electromagnetic fields level 3 conforming to IEC 61000-4-3,Immunity to microbreaks and voltage drops conforming to IEC 61000-4-11

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 10.3 cm
Package 1 Width 10.3 cm
Package 1 Length 2.5 cm
Package 1 Weight 184.0 g
Unit Type of Package 2 S02
Number of Units in Package 2 36
Package 2 Height 15.0 cm
Package 2 Width 30.0 cm
Package 2 Length 40.0 cm
Package 2 Weight 6.926 kg

Contractual warranty

Warranty 18 months

Documentation

Product Datasheet

Instruction sheet

Catalogue