This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Schneider Electric

LTMR100PFM

LTMR100PFM Schneider Electric

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for LTMR100PFM Schneider Electric

LTMR100PFM Schneider Electric - motor controller LTMR TeSys T - 100..240 V AC 100 A for Profibus DP

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Available on back order
4 - 6 W.Weeks
£371.72 Exc. VAT
£446.06 Inc. VAT

Main

Range TeSys
Product name TeSys T
Device short name LTMR
product or component type Motor controller
device application Equipment monitoring and control
Measurement current 5…100 A
[Us] rated supply voltage 100...240 V AC 50/60 Hz
current consumption 8...62.8 mA
Supply voltage limits 93.5…264 V AC
communication port protocol Profibus DP
Bus type Profibus DP polarised 2-wire RS485 interface, addressing 1...125, transmission rate 9.6 kbit/s...12 Mbit/s, SUB-D 9 with 2 shielded twisted pairs, type A,Profibus DP polarised 2-wire RS485 interface, addressing 1...125, transmission rate 9.6 kbit/s...12 Mbit/s, terminal block with 2 shielded twisted pairs, type A

Complementary

[Ui] rated insulation voltage 690 V conforming to EN/IEC 60947-1,690 V conforming to CSA C22.2 No 14,690 V conforming to UL 508
[Uimp] rated impulse withstand voltage 4 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1,6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1,0.8 kV communication circuit conforming to EN/IEC 60947-4-1
Short-circuit withstand 100 kA conforming to EN/IEC 60947-4-1
Associated fuse rating 4 A gG for output,0.5 A gG for control circuit
Protection type Thermal overload protection,Power factor variation,Overload,Locked rotor,Thermal protection,Reverse polarity protection,Phase unbalance,Earth-leakage protection,Phase failure,Load fluctuation,Overload (long time)
Network and machine diagnosis type Starting current and time,Trip history information,Running hours counter/operating time,Phase fault and earth fault trip counters,Trip context information,Event recording,Remaining operating time before overload tripping,Motor control command recording,Waiting time after overload tripping,Fault recording
Logic input number 6
Input current 3.1 mA at 100 V,7.5 mA at 240 V
Current state 0 guaranteed Logic input: 0...40 V and <= 15 mA for 25 ms
Current state 1 guaranteed Logic input: 79...264 V and >= 2 mA for 25 ms
maximum output switching frequency 2 Hz
Load current 5 A at 250 V AC for logic output,5 A at 30 V DC for logic output
Permissible power 480 VA (AC-15), Ie = 2 A, 500000 cycles (output),30 W (DC-13), Ie = 1.25 A, 500000 cycles (output)
Maximum operating rate 1800 cyc/h
Contacts type and composition 1 NO + 1 NC fault signal,3 NO
Metering type Earth-fault current,Phase current I1, I2, I3 RMS,Temperature,Imbalance current,Average current Iavg
Measurement accuracy 5...15 % earth fault current internal measurement,1 % voltage (100...830 V),3 % power factor,5 % earth fault current external measurement,+/- 30 min/year internal clock,0,02 temperature,5 % active and reactive power,0,02 current
Overvoltage category III
Connection pitch 5.08 mm
Connections - terminals Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24...AWG 14) flexible with cable end,Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24...AWG 14) flexible without cable end,Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24...AWG 14) flexible without cable end,Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24...AWG 14) solid without cable end,Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24...AWG 14) flexible with cable end,Control circuit: connector 2 cable(s) 0.2…1.5 mm² (AWG 24...AWG 14) flexible without cable end,Control circuit: connector 2 cable(s) 0.5…1.5 mm² (AWG 24...AWG 14) flexible without cable end,Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24...AWG 14) solid without cable end
Tightening torque Control circuit: 0.5…0.6 N.m flat screwdriver 3 mm
Pollution degree 3
Electromagnetic compatibility Electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2,Radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3,Fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4,Fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4,Voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11,Conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6,Temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5,Temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5,Control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5,Communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5,Relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5,Relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5,Control circuit: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5
Width 91 mm
Height 61 mm
Depth 122.5 mm
net weight 0.53 kg
Web services Web server
compatibility code LTMR

Environment

Standards EN 60947-4-1,IACS E10,CSA C22.2 No 14,UL 508,IEC 60947-4-1
Product certifications KERI,RMRoS,ABS,UL,ATEX,NOM,RINA,BV,CCC,GL,DNV,CSA,LROS (Lloyds register of shipping),EAC,C-Tick
Protective treatment 12 x 24 hour cycles conforming to EN/IEC 60068-2-30,48 h conforming to EN/IEC 60070-2-11,TH conforming to EN/IEC 60068
Fire resistance 650 °C conforming to EN/IEC 60695-2-12,960 °C conforming to UL 94
Ambient air temperature for operation -20…60 °C
Ambient air temperature for storage -40…80 °C
Operating altitude <= 2000 m without derating
Mechanical robustness Vibrations mounted on symmetrical rail: 1 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6,Vibrations plate mounted: 4 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6,Shocks half sine wave acceleration: 15 Gn for 11 ms conforming to EN/IEC 60068-2-27
IP degree of protection IP20

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 10.000 cm
Package 1 Width 7.200 cm
Package 1 Length 13.500 cm
Package 1 Weight 530.000 g
Unit Type of Package 2 S02
Number of Units in Package 2 10
Package 2 Height 15.000 cm
Package 2 Width 30.000 cm
Package 2 Length 40.000 cm
Package 2 Weight 5.649 kg

Contractual warranty

Warranty 18 months

Documentation

Product Datasheet

User guide

Instruction sheet

Catalogue

CAD

Environmental disclosure

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible